Dyna-Glo HA1360BK Скачать руководство пользователя страница 7

7

IMPORTANT NOTICE

REGARDING THIRD PARTY ATTACHMENTS TO  ALL

DYNA-GLO HEATAROUND360 MODELS 

GHP Group, Inc. is a leading manufacturing company specializing in portable heating products. Our products can be found at most 
major home centers, hardware stores and internet retailers across North America. In 2016, GHP introduced the HeatAround360 and 
HeatAround360 Elite portable heaters into the market. These heaters, which are sold under the Dyna-Glo brand feature an Oxygen 
Depletion Sensor (“ODS”), which shuts off the heater if the oxygen in the room gets below a certain point and a tip-over safety switch 
that turns it off in the event of it being knocked on its side. These features allow the heater to be safely used during numerous indoor 
and outdoor activities.

GHP recognizes the many different third party attachments for the HeatAround360 and is aware of their intended purpose of using 
the HeatAround360 to heat or cook food. GHP strongly encourages that these third party attachments NOT be used as they are nei-
ther certified, nor safe to be used to warm or cook food of any kind. HeatAround360 Heaters are not certified as a cooker and are not 
designed to operate in this manner. GHP explicitly prohibits the use of any type of non-approved attachments with its HeatAround360 
heaters.

This product is a heater. It is certified to CSA International Requirement Section CSA 4.98 U.S.

"Gas Fired Portable Heaters for Recreational or Commercial Use." This product is NEVER to be used for the cooking or warming of 
foods as doing so can interfere with the safety systems of the heater, which may result in a fire, explosion, the production of deadly 
carbon monoxide, and personal injury or death to you or others. NEVER use hand-made or third party accessories or attachments 
with this heater; this is extremely dangerous and may result in personal injury or.death to you or others

WARRANTY LANGUAGE

GHP Group, Inc. warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from 
date of purchase. GHP Group, Inc. will repair or replace this product free of charge if it has been proven to be defective within the 
1-year period and is returned at customer expense with proof of purchase to GHP Group, Inc. within the warranty period. DISCLAIM-
ER: This warranty does not cover any product that: a) has been subject to misuse or neglect; b) has been used in a manner inconsis-
tent with the warnings and instructions contained in the owner’s manual, including but not limited to using a heater for the cooking or 
warming of foods; or c) has been used with hand-made or third party accessories or attachments.

GHP prohibits the HeatAround360 heaters from being used for cooking or warming foods. Third party attachments intended to 
change the intended operation of the HeatAround360 are prohibited for use as they could cause serious harm to consumers. Using 
such products with GHP heaters will immediately void the product warranty. GHP values the safety of its consumers above all else 
and appreciates your continual trust in all GHP products. Please feel free to contact us at [email protected] with 
any questions.

•      

CAUTION:

 After turning heater off, wire guard will remain hot. 

  Allow to thoroughly cool before moving or storing.

•      

CAUTION: 

When not in use, the gas must be turned off at the LPgas supply cylinder. As stated before allow heater to use up 

  propane in supply line until heater shuts off. When the LP-gas supply cylinder is not disconnected from the heater, the heater 
  and the cylinder must be stored outdoors, in a well ventilated space, out of reach of children, and must not be stored in a 
  building, garage or any other enclosed area. Disconnect all cylinders when heater is not in use.

•      

CAUTION: 

Indoor storage of the heater is permissible only if the cylinder is disconnected and removed from the heater. Cylinders   

  must be stored outdoors out of the reach of children and must not be stored in a building, garage or any other enclosed area.

Both the 1 lb. and 20 lb. cylinders must be in an upright position during use to insure proper vapor withdraw.

1 lb. cylinders must be Dept. of Transportation (DOT) constructed and approved and have an outlet connection compatible with a 
CGA 600 fitting.

NEVER LEAVE THE HEATER 

UNATTENDED WHILE BURNING!

WARNING:

Содержание HA1360BK

Страница 1: ...icemustbeperformedbyaqualifiedserviceagency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided...

Страница 2: ...or its controls can be dangerous Some people pregnant women persons with heart or lung disease anemia those under the influence of alcohol those at high altitudes are more affected by carbon monoxide...

Страница 3: ...ric conditions heater may not re light When moving heater when lit or bumping heater setting it down tip over switch may shut off heater If this happens re light Operating time will vary depending on...

Страница 4: ...control which has been under water When used without adequate combustion and ventilation air this heater may give off excessive CARBON MONOXIDE an odorless poisonous gas Some people pregnant women pe...

Страница 5: ...Tank Regulator Access Door Fig 1 1 lb Cylinder Tank Installation Fig 1a Remote Tank Installation EMERGENCY INDOOR USE Adequate combustion and ventilation air must be provided when the appliance is in...

Страница 6: ...er b Install the GHP hose connector model HAKITDG Check for gas leaks by using a 50 soap water solution at the joint of the regulator and cylinder 3 Depress and turn the control knob to the pilot posi...

Страница 7: ...roup Inc will repair or replace this product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchase to GHP Group Inc w...

Страница 8: ...n lead to a fire 1 Allow heater to thoroughly cool before performing any maintenance 2 Remove disposable 1 lb cylinder s from heater or turn OFF gas supply at remote cylinder valve and disconnect hose...

Страница 9: ...s turned there is a spark at ODS pilot but no ignition 1 Tank shutoff valve is closed 2 Control knob not fully pressed in while pressing ignitor button 3 Air in gas lines when installed 4 ODS pilot is...

Страница 10: ...just after burner is lit or shut off 1 Metal is expanding while heating or contracting while cooling 1 This is common with most heaters If noise is excessive contact qualified service technician Heat...

Страница 11: ...0 15 B HA1360 15 C Access Door 7 1 HA1360 01 HA1360 01 HA1360 10 HA1360 10 BurnerAssembly 8 N A HA360 HK HA360 HK HA360 HK HA360 HK Hardware Kit Includes all hardware to assemble unit 9 1 1 HA1360 21...

Страница 12: ...60 23 HA360 23 Control Knob 6 1 HA2360 PBA RD HA2360 PBA B HA2360 PBA C Plastic BaseAssembly 7 2 HA2360 15 RD HA2360 15 B HA2360 15 C Door 8 1 KW 16B KW 16B KW 16B Tip Switch 9 1 2 HA2360 21 HA2360 21...

Страница 13: ...ntative This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO REGISTER THE WARRANTY ON YOUR HEATER PLEASE FILL OUT THIS CARD COMPLETELY AND...

Страница 14: ...SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280...

Страница 15: ...r realizadas por una agencia de servicio calificada Este es un calefactor port til a gas sin salida al exterior Utiliza el aire ox geno del rea en que se utiliza Se debe proporcionar cantidad adecuada...

Страница 16: ...groso Algunas personas embarazadas personas con enfermedades card acas o pulmonares an micas las que est n bajo los efectos del alcohol o las que est n a alturas elevadas se ven m s afectadas por el m...

Страница 17: ...posible que el calefactor no se vuelva a encender Si mueve el calefactor cuando est encendido o si al colocarlo en el suelo lo golpea es posible que el interruptor de vuelco haga que se apague el cal...

Страница 18: ...calefactor y reemplace las piezas del sistema de control y los controles de gas que se hayan mojado Si se lo utiliza sin un flujo adecuado de aire de combusti n y ventilaci n el calefactor puede emit...

Страница 19: ...ue del cilindro de 1 lb aprobado por DOT Fig 1a Instalaci n del tanque remoto PARA USO EN INTERIORES Y DE EMERGENCIA Cuando el artefacto est en uso se debe proporcionar cantidad adecuada de aire de co...

Страница 20: ...la puerta de acceso e instale la fuente de combustible propano a Instale un cilindro de gas propano de 1 lb con certificaci n del Departamento de Transporte DOT b Instale el conector de manguera GHP m...

Страница 21: ...cha de compra GHP Group Inc reparar o reemplazar este producto sin cargo si se prueba que el defecto se produjo dentro del per odo de 1 a o y el cliente devuelve el producto a GHP Group Inc junto con...

Страница 22: ...incendio 1 Deje que el calefactor se enfr e completamente antes de realizar cualquier tarea de mantenimiento 2 Extraiga los cilindros de 1 lb del calefactor o cierre el suministro de gas en la v lvul...

Страница 23: ...encendido Cuando se gira la perilla del dispositivo de encendido hay una chispa en el ODS piloto pero no se enciende 1 La v lvula de cierre del tanque est cerrada 2 La perilla de control no se presion...

Страница 24: ...ce y corrija todas las fugas El calentador produce un ruido de chasquido inmediatamente despu s de encender o apagar el quemador 1 El metal se expande al calentarse y se contrae al enfriarse 1 Esto es...

Страница 25: ...e pl stico 6 1 HA1360 15 RD HA1360 15 RD HA1360 15 B HA1360 15 C Puerta de acceso 7 1 HA1360 01 HA1360 01 HA1360 10 HA1360 10 Conjunto del quemador 8 N A HA360 HK HA360 HK HA360 HK HA360 HK Kit de tor...

Страница 26: ...A2360 04 HA2360 04 Rejilla de protecci n 5 1 HA360 23 HA360 23 HA360 23 Perilla de control 6 1 HA2360 PBA RD HA2360 PBA B HA2360 PBA C Conjunto de la base de pl stico 7 2 HA2360 15 RD HA2360 15 B HA23...

Страница 27: ...CITAS INCLUIDAS ENTRE OTRAS LAS GARANT AS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN DETERMINADO EL RECURSO PROPORCIONADO EN ESTA GARANT A ES EXCLUSIVO Y SE OTORGA EN REEMPLAZO DE TODOS LOS OTROS REC...

Страница 28: ...jeta de registro de la garant a dentro de los catorce 14 d as de la fecha de compra Tambi n puede registrar la garant a por Internet en www ghpgroupinc com Complete el n mero de serie Conserve esta pa...

Отзывы: