Dyna-Glo Delux RMC-KFA120TDLX Скачать руководство пользователя страница 1

4 2 21- 0 0 5 9- 0 0

06/04  Rev. 00

EDITION  2004

PORTABLE

FORCED AIR HEATERS

“USER’S MANUAL”

Before the first use of this heater, please read this USER’S MANUAL very
carefully.  This USER’S MANUAL has been designed to instruct you as to
the proper manner in which to assemble, maintain, store, and most
importantly, how to operate the heater in a safe and efficient manner.
Please keep this manual for future reference.

CFM HOME PRODUCTS

2695 MEADOWVALE BOULEVARD
MISSISSAUGA, ONTARIO L5N 8A3

1-800-668-5323

MODEL : RMC-KFA65TDLX, RMC-KFA120TDLX

RMC-KFA170TDLX

LISTED

Содержание Delux RMC-KFA120TDLX

Страница 1: ...R S MANUAL has been designed to instruct you as to the proper manner in which to assemble maintain store and most importantly how to operate the heater in a safe and efficient manner Please keep this...

Страница 2: ...eping areas 2 RISK OFBURNS FIRE EXPLOSION NEVERuse any fuel other than 1 K kerosene in this heater 1 fuel oil is the only acceptable substitute NEVERuse fuel such as gasoline benzene paint thinners or...

Страница 3: ...ND ALL PACKING MATERIALS FROM THE BOX NOTE Save the shipping carton and packing materials for future storage RMC KFA 65TDLX RMC KFA120TDLX RMC KFA170TDLX Wheel No Yes Yes Wheel Bar No Yes Yes Wheel Ca...

Страница 4: ...quired Medium Phillips Screwdriver 1 Assembling Handle 1 Align boss on bottom of handle with the 2 holes on the shell cover as shown in Figure 6 NOTE Be sure to match the tab in the bottom of the hand...

Страница 5: ...Power ON OFF Temp Setting 5 OVERVIEW OF HEATERS DESIGN Fuel System This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through...

Страница 6: ...RVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT USE ORIGINAL EQUIPMENT REPLACEMENT PARTS Use of third party or other alternate components will void warranty and may cause unsafe operating conditions...

Страница 7: ...eaning Photocell 11 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING D FAN BLADES CLEAN EVERY SEASON OR AS NEEDED Remove upper shell See 10 page Use 1 8 allen wrench to loosen set screw which holds Fan...

Страница 8: ...PUMP PRESSURE ADJUSTMENT Start Heater See Operation Page 8 and allow motor to reach full speed Adjust Pump Pressure Using a Flat blade screwdriver Turn Relief Valve clockwise to increase pressure Turn...

Страница 9: ...70 000 Fuel Consumption Gal Hr 0 5 0 9 1 3 Fuel Tank Capacity Gal 5 0 10 0 12 0 Pump Pressure PSI 3 5 4 5 6 5 Volt Hz 120Vac 60Hz 120Vac 60Hz 120Vac 60Hz Amps 1 6 2 5 3 2 Phase 1 1 1 Size W D H 14 5 2...

Страница 10: ...00 3431 0010 00 3311 0002 00 SP KFA1008 4349 0017 00 4342 0009 00 4329 0013 00 3341 0016 00 See below 3970 0034 00 Capacitor Motor Supportor Lock Nut Pump Body Bolt PH Insert Rotor Kit Blade End Pump...

Страница 11: ...00 SP KFA1007 See below 3531 0007 00 3541 0020 00 3541 0020 00 SP KFA1003 4343 0016 00 3431 0010 00 3311 0002 00 SP KFA1009 4349 0017 00 4342 0009 00 4329 0013 00 3341 0017 00 See below 3970 0029 00...

Страница 12: ...trol Knob Side Cover R BRACKET SIDE COVER RATING PLATE Power Switch Side Cover L SP KFA1000 See SP KFA1000 3531 0008 00 3541 0020 00 4329 0014 00 See SP KFA1005 See SP KFA1005 SP KFA1005 3221 0029 00...

Отзывы: