7

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

TO STOP HEATER

1. Turn operating switch to “OFF”.

This will cause heater flame to go out.

The motor will continue to run during the cooling cycle.

(Room Temp. Display will show “CC” during the cooling cycle)

This allows the fan to cool the combustion chamber. When the cooling cycle

(approx.1Min) is finished, the motor will stop. 

Do not unplug heater until cooling cycle is finished.

2. Unplug power cord.

3. To temporarily stop heaters, set thermostat at a temperature lower than air around heater, 

Heater will cycle back on if air temperature around heater matches thermostat setting.

TO RESTART HEATER

1. Wait until cooling cycle is finished after stopping heater.

2. Repeat steps under to start HEATER.

EXTRA ELECTRIC OUTLET

The cooling cycle cools the combustion chamber.

Figure 5. EXTRA ELECTRIC OUTLET

CAUTION ; Never unplug heater while heater is running

Heater must go through cooling cycle. The cooling cycle cools the 

combustion chamber. Damage to heater can occur if combustion chamber

is not cooled. Do not restart heater until cooling cycle is complete.

COVER

ELECTRIC OUTLET

Always cover electric outlet when not in use.

Do not plug in and use an appliance of more than 120V 5A current in this outlet.        

WARNING ; SHOCK HAZARD!

CAUTION ; Do not restart heater until cooling cycle is finished.

Содержание Delux KFA400DGD

Страница 1: ...OSENE PORTABLE FORCED AIR HEATERS USER S MANUAL AND OPERATING INSTRUCTIONS Before the first use of this heater please read this USER S MANUAL very carefully This USER S MANUAL has been designed to ins...

Страница 2: ...ndle service ahot operatingor plugged inheater NEVERtransport heater with fuelin it s tank Whenused with an optionalthermostat or ifequippedwitha thermostat heater maystart at anytime ALWAYSlocate hea...

Страница 3: ...N O L 8 9 E C N A N E T N I A M 9 15 14 E D I U G G N I T O O H S E L B U O R T 11 REPLACING FUSE 10 16 M A R G A I D G N I R I W 12 17 S N O I T A C I F I C E P S 13 18 G N I W A R D S T R A P D E D...

Страница 4: ...de one wheel on to each side of the axle Attach one cap nut on to each side of the threaded axle and tighten well 3 Place heater on wheel support frame Make sure air inlet end rear of heater is over w...

Страница 5: ...THAT IS CLEARLY MARKED KEROSENE NEVER STORE KEROSENE IN A RED CONTAINER Red containers are associated with gasoline NEVER store kerosene in the living space Kerosene should be stored in a well ventil...

Страница 6: ...If this device activates and turns your heater off it may require service C Flame Out Sensor Utilizes a photocell to monitor the flame in burn chamber during normal operation It will cause the heater...

Страница 7: ...40 110 and push operating switch to ON position power indicator lamp and room temp display will light and heater will start NOTE Room Temp display indicates as following When room temp is less than 0...

Страница 8: ...air temperature around heater matches thermostat setting TO RESTART HEATER 1 Wait until cooling cycle is finished after stopping heater 2 Repeat steps under to start HEATER EXTRA ELECTRIC OUTLET The...

Страница 9: ...ne over summer months for use during next heating season Using old fuel could damage heater 3 Reinstall Fuel Drain Bolt to Fuel tank and tighten firmly using 3 4 socket or adjustable wrench IMPORTANT...

Страница 10: ...Y SEASON OR AS NEEDED Remove upper shell See figure 7 above Clean fan blades and air deflectors using a soft cloth moistened with kerosene or solvent Dry fan blades and air deflectors thoroughly Reins...

Страница 11: ...emove five screws using medium phillips screwdriver and remove burner head from combustion chamber Carefully remove nozzle from burner head using 5 8 socket wrench Blow compressed air through face of...

Страница 12: ...n guard E PHOTOCELL CLEAN PHOTO CELL ANNUALLY OR AS NEEDED Remove upper shell See Page 9 Remove photocell from photocell Bracket and disconnect photocell from connector Clean photocell lens with cotto...

Страница 13: ...lter bottom Tighten firmly FILTER BOTTOM MAGNET FUEL FILTER GASKET FILTER TOP Figure 14 Remove Tank Fuel Filter Figure 15 Fuel Pump Filter Remove fan guard See Figure 11 Disconnect fuel line B from pu...

Страница 14: ...iver Turn pressure adj Screw to clock wise to increase pressure Turn screw to counter clock wise to decrease pressure Set pump pressure to 125 PSI Stop heater See operation page 6 Remove pressure gaug...

Страница 15: ...ury unplug the power cord before replacing fuse 1 Unplug heater 2 Turn Fuse Cover COUNTERCLOCKWISE 45 using a flat blade screwdriver and remove Fuse from Fuse Holder 3 Replace Fuse with enclosed fuse...

Страница 16: ...l filter 4 See Fuel Filter page 12 5 Dirt in nozzle 5 See Nozzle page 10 6 Water in fuel tank 6 Flush fuel tank with clean 7 Bad electrical connection kerosene page 9 between ignitor and MAIN 7 Check...

Страница 17: ...LECTRIC POWER LAMP ROOM SENSOR PHOTOCELL CN5 WHITE WHITE TEMP CONTROL LED THERMOSTAT CN2 AC2 BLUE BLUE CN6 BLK CN1 AC1 WHT RED WHITE CONTROL PCB BLACK 45uF 400Vac SPARK PLUG CAPACITOR BLACK WHITE PUMP...

Страница 18: ...M 0 0 0 0 0 4 r H U T B Fuel Consumption Gal Hr 3 0 11 36 Fuel Tank Capacity Gal 29 0 110 0 Pump Pressure PSI kgf 125 8 79 4 4 0 6 C A V 0 2 1 s p m A z H s t l o V 1 e s a h P Size D W H Inch 52 5 31...

Страница 19: ...S DRAWING KFA400DGD MODEL NOTE SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS 4 8 37 38 39 19 36 7 9 11 10 12 13 14 2 45 48 32 22 23 1 3 5 15 19 19 23 24 19 19 21 26 27 29 30 11 16 16 28 31...

Страница 20: ...r Cover Igniter Motor Pump Assembly P C B Assembly Cover Display Window Display Operating Switch Fuse Holder Fuse Safe Guard Assembly Bracket Filter Mesh Guard Impeller Washer Fan Assembly Bolt Standa...

Страница 21: ...41 0057 00 9 Solenoid Valve 39A0 0084 00 10 Elbow Male 3740 0037 00 KEY NO DESCRIPTION PART NO 1 Motor 3970 0081 00 2 Supportor Motor 3121 0334 00 3 Bolt HH 4321 0182 00 4 Nut Lock 4331 0022 00 5 Coup...

Страница 22: ...3 Cord Wrap 3221 0052 00 2 4 Threaded Axle 3541 0096 00 1 5 Wheel 3720 0004 00 2 6 Hardware Kit HW KFA1019 1 6 1 Screw L INCLUDED IN HARDWARE KIT 6 6 2 Screw S INCLUDED IN HARDWARE KIT 6 6 3 Nut INCL...

Страница 23: ......

Страница 24: ......

Отзывы: