IMPORTANT:

 Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, 

explosion, electrical shock, and carbon monoxide poisoning.

IMPORTANT SAFETY INFORMATION 

 

 

Installation and repair should be done by a qualified service person. The appliance should be 

inspected before use and at least annually by a professional service person. More frequent 

cleaning may be required due to excessive lint from carpeting, bedding material, etc. It 

is imperative that control compartments, burners and circulating air passageways of the 

appliance be kept clean.

 

 

WARNING:

 Any change to this heater or its controls can be dangerous. 

 

WARNING:

 

Carefully supervise young children when they are in the room with the heater.

 

WARNING: 

Heater becomes very hot when operating. Children and adults should be alerted 

       to the hazard of high surface temperatures and should stay away to avoid burns or clothing 

       ignition

 Heater will remain hot for a time after shutoff. Allow surfaces to cool before touching. 

 

 

WARNING:

 Make sure any panel, safety screen or guard removed for servicing an appliance   

       is replaced prior to operating the heater

 

WARNING:

 Keep the appliance area clear and free from combustible materials, gasoline, and  

 

other flammable vapors and liquids. 

 

WARNING:

 Do not place clothing or other flammable material on or near the appliance. Never  

 

place any objects on the heater.

       

WARNING:

 Due to high temperatures, locate this appliance out of traffic and away from

       furniture and draperies.

This appliance is intended for supplemental heating.

CARBON MONOXIDE POISONING: 

Early signs of carbon monoxide poisoning resemble the flu with 

headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get 

fresh air immediately! Have heater serviced. Some people are more affected by carbon monoxide than 

others. These include pregnant women, people with heart or lung disease, people who are 

anemic, those under the influence of alcohol, and those living in high altitudes.

NATURAL AND PROPANE/LP GAS:

 Natural and Propane/LP gases are odorless. An odor-making 

agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas 

can fade. Gas may be present even though no odor exists. Make certain you read and understand all 

warnings. Keep this manual for reference. It is your guide to operating this heater safely.

If the heater is being installed in a residential garage, it must be secured firmly to the 

wall, a minimum of 18 in. (457mm) above the floor. The heater must be located so that it 

is protected against any possibility of damage by a moving vehicle, etc.

Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any

flammable liquids which may be improperly stored or accidentally spilled. If the smell of 

gasoline is present, do not operate this heater until the area has been properly ventilated.

WARNING:

Содержание BFSS10LPT-2P

Страница 1: ...ervice must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 8 of this manual This appliance may be installed in an aftermarket permanently located m...

Страница 2: ......

Страница 3: ...000 20 000 MIN BTU 8 000 16 000 Fuel Type Propane Propane Ignition Electronic Push Button Electronic Push Button Manifold Pressure 10 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 11 in W C 11 in W C Dimensions in H x W x D Height includes legs 20 00 in x 17 32 in x 9 49 in 24 02 in x 20 94 in x 10 08 in Fan Ratings Select Models 120V 60Hz...

Страница 4: ...elect Models 120V 60Hz 18W 0 15A SERIES BFSS10NGT 2N BFSS20NGT 2N MAX BTU 10 000 20 000 MIN BTU 5 000 10 000 Fuel Type Natural Gas Natural Gas Ignition Electronic Push Button Electronic Push Button Manifold Pressure 5 in W C 5 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 6 in W C 6 in W C Dimensions in H x W x D Height includes legs 20 00 in x 17 3...

Страница 5: ...ammable material on or near the appliance Never place any objects on the heater WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies This appliance is intended for supplemental heating CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the heater may no...

Страница 6: ... through 25 4 Keep all air openings in front top and bottom of heater free of objects and debris to ensure adequate air for proper combustion 5 If heater shuts off do not relight until you have provided fresh outside air If heater keeps shutting off have it serviced 6 Do not run heater Where flammable liquids or vapors are used or stored Under dusty conditions 7 Before using furniture polish wax c...

Страница 7: ...r State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bath...

Страница 8: ...pproximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps will help ...

Страница 9: ...e unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combusti...

Страница 10: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used _______ BTU hr...

Страница 11: ...s directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate...

Страница 12: ...ounted on the wall or on the floor using the support legs Select Models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining wall Always maintain a minimum of 36 in clearance from furniture and draperies A second side wall must be at least 18 in away from the other side of the heater LEFT RIGHT TOP BOTTOM FRONT Rear 8 in 36...

Страница 13: ...sconnected from gas supply and removed from wall before installing fan accessory Contact a qualified service person to do this 2 Remove fan knock out panel using a screwdriver See Fig 9 Attach Fan to the rear panel of the heater using the four screws provided NOTE Be sure the rocker switch is positioned in the upper right corner See Fig 10 3 This fan is equipped with manual MAN and automatic AUTO ...

Страница 14: ...he table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table edge 3 Fasten Support Legs to heater using Support Leg Screws Fig 13 Note If the heater is to be installed directly on carpet ing tile or other combustible material other than wood flooring the applia...

Страница 15: ... wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wood screws ST 8 45 16 total through these holes only 3 Remove tape and mounting bracket from wall Attaching Mounting Bracket To Wall Note Expansion bracket wood screws ST 8 45 16 and wall hanging spacers are in hardware ...

Страница 16: ...ith expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is firmly fastened to wall 8 Check that the bracket is secure before mounting heater Attaching Wall Hanging Spacers to Heater WARNING Failure to properly install the wall hanging spacers may result in pro...

Страница 17: ...s line pressure is higher the unit will not work and heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting into gas piping and or fittings CAUTION Use pipe joint ...

Страница 18: ...G 3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pressure Testing Gas Supply Equal To or less than 1 2 PSIG 3 5kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of t...

Страница 19: ...o light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it...

Страница 20: ...for 30 seconds after pilot lights Release control knob Note If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call your service technician or gas supplier If the control knob does not pop up when released stop and immediately and call your servic...

Страница 21: ...PERATION INSPECTING BURNERS Check pilot flame pattern daily when in use and at least yearly by a qualified service agency PILOT FLAME PATTERN Fig 26 shows a correct pilot flame pattern Fig 27 shows an incorrect pilot flame pattern The incor rect pilot flame is not touching the thermocouple This will cause the thermocouple to cool which shuts the heater off If pilot flame pattern is incorrect turn ...

Страница 22: ...lored flame may be caused by airborne dust dander pet hair etc Additionally an excess amount of Mercaptane in the fuel can result in an orange or yellow colored flame The upper third of flame may be bright yellow when operated on propane When this heater is set for use on propane gas the upper one third of the flame may be bright yellow When this heater is set for use on natural gas a slight yello...

Страница 23: ...ow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Remove 4 screws 2 screws on each side of the front panel 3 Pull front panel forward 4 Blow air through the ports slots and holes in the burner Also clean the pilot assembly A yellow tip on the pilot flame indicates dust and dirt in the pilot asse...

Страница 24: ...ode is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor or ignition mod ule 7 Bad battery 1 Replace ODS 2 Replace ODS 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace ignitor or ignition mo...

Страница 25: ...stomer service 4 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance page 22 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Clean burner orifice see Care and Mainte...

Страница 26: ...er 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 23 2 Control valve is defective 1 Locate and correct all leaks see Checking Gas Connections page 17 2 Contact customer service Moisture conden sation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion ...

Страница 27: ...odels 1 There is no power to the fan 2 Fan is set to AUTO 3 Fan motor is bad 1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is not in fan path 3 Replace fan 1 Verify fan is plugged in and set to MAN or AUTO 2 Allow 5 10 minutes for fan to engage 3 Replace fan ...

Страница 28: ...s Pilot 1 IR30K 12 NG L 950 IR30K 12 NG L 950 IR30K 12 NG L 950 Ignition Wire 1 IR30K GHP 03 L 1000 IR30K GHP 03 L 1000 IR30K GHP 03 L 1000 Fan Assembly Select Models 1 AQ000232 AQ000232 AQ000232 Thermostatic Gas Valve SIT 630 1 0630560 0630560 0630560 Support Legs Select Models 2 AQ000038 AQ000038 AQ000038 Glass Panel 1 AQ000164 AQ000148 AQ000180 Hardware Pack 1 AQ000233 AQ000233 AQ000233 Replace...

Страница 29: ..._______________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please Take a Minute To Give Us Your Answers To The Following Questions All Responses Are Used Solely For Market Research And Are Held In Strict Confidence Who primarily decided this purchase Male Female 18 24 ...

Страница 30: ...rds SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GHP Group Inc 6440 W Howard St Niles IL 60714 3...

Страница 31: ...actor accionado por gas no ventilado Utiliza aire oxígeno de la habitación en la cual está instalado Deben tomarse medidas para una combustión y aire de ventilación adecuados Consulte la sección Aire para la combustión y ventilación página 8 de este manual C US C US ANS Z21 11 2 2013 Calentadores de habitación accionados por gas Volumen II Calentadores de habitación no ventiladas CALEFACTOR DE PAR...

Страница 32: ...sión del distribuidor 10 pulg de columna de agua 10 pulg de columna de agua Presión de gas de entrada Máximo 14 pulg de columna de agua 14 pulg de columna de agua Mínimo Para fines de ajuste de entrada 11 pulg de columna de agua 11 pulg de columna de agua Dimensiones pulg Alto x Ancho x Diámetro La altura incluye las patas 20 00 pulg x 17 32 pulg x 9 49 pulg 24 02 pulg x 20 94 pulg x 10 08 pulg Ca...

Страница 33: ...g de columna de agua 14 pulg de columna de agua Mínimo Para fines de ajuste de entrada 6 pulg de columna de agua 6 pulg de columna de agua Dimensiones pulg Alto x Ancho x Diámetro La altura incluye las patas 20 00 pulg x 17 32 pulg x 9 49 pulg 24 02 pulg x 20 94 pulg x 10 08 pulg Capacidades nominales del ventilador Modelos seleccionados 120V 60Hz 18W 0 15A 120V 60Hz 18W 0 15A SERIE BFSS30NGT 2N B...

Страница 34: ... PELIGRO DE ENVENENAMIENTO CON MONÓXIDO DE CARBONO Las señales tempranas de envenenamiento con monóxido de carbono se parecen a la gripe con dolores de cabeza mareos o náusea Si tiene estas señales el calefactor puede no estar funcionando adecuadamente Respire aire fresco de inmediato Haga que se le de servicio al calefactor Algunas personas resultan más afectadas que otras por el monóxido de carb...

Страница 35: ...uras de aire en el frente parte superior y parte inferior del calentador libres de objetos y desechos para asegurar aire adecuado para una combustión apropiada 5 Si el calefactor se apaga no lo encienda de nuevo sino hasta que haya suministrado aire fresco del exterior Si el calefactor se mantiene apagándose haga que se le dé servicio 6 No haga funcionar el calefactor Donde se almacenen o usen líq...

Страница 36: ... funcionamiento del calentador Estado de Massachusetts La instalación debe ser hecha por un fontanero o técnico de gas calificado en la Commonwealth de Massachusetts Los vendedores de calefactores complementarios de habitación no ventilados accionados por propano o gas natural deben proporcionar a cada comprador una copia de 527 CMR 30 con la venta de la unidad En el Estado de Massachusetts los ca...

Страница 37: ...e aproximadamente 1 onza 30 mL de agua por cada 1 000 BTUs 0 3 Kw de entrada de gas por hora Un calefactor no ventilado de habitación está previsto como un calefactor comple mentario en lugar de una fuente primaria de calor En la mayoría de aplicaciones de calor comple mentario el vapor de agua no crea un problema En la mayoría de aplicaciones el vapor de agua mejora la atmósfera de baja humedad q...

Страница 38: ...con puertas son consideradas una parte del espacio no confinado Este calefactor no deberá ser instalado en un espacio confinado o construcción inusualmente hermética a menos que se tomen medidas para una combustión y aire de ventilación adecuados Las habitaciones contiguas se conectan solo si hay pasillos sin puertas o rejillas de ventilación entre ellas Construcción inusualmente hermética El aire...

Страница 39: ...r Ejemplo Leños de calentador a gas __________BTU hr Calentador de agua a gas 30 000 BTU hr Otros aparatos a gas ____BTU hr Calefactor de tiro natural 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr No incluya aparatos a gas de ventilación directa La ventilación directa extrae aire para la combustión del exterior y descarga al exterior 4 Compare los BTU hr máximos que el espacio puede soportar ...

Страница 40: ...ilación Debe proporcionar dos aberturas permanentes una dentro de 12 pulg del techo y otra dentro de 12 pulg del piso Conecte estos artículos directamente al exterior o a espacios abiertos al exterior Estos espacios incluyen áticos y cámaras Siga el Código Nacional de Gas Combustible NFPA 54 ANS Z223 1 Aire para la combustión y ventilación para el tamaño requerido de las rejillas o ductos de venti...

Страница 41: ...se puede montar en la pared o en el piso usando las patas soportes Modelos seleccionados ADVERTENCIA Mantenga los espacios libres mínimos mostrados en Ver Fig 3 Si puede proporcione espacios libres más grandes desde el piso techo y pared adyacente Una segunda pared lateral debe estar al menos a 18 pulg del otro lado del calefactor Mantenga siempre un mínimo de 36 pulg de espacio libre de muebles y...

Страница 42: ...alar el accesorio del ventilador Contacte a una persona de servicio calificada para hacer esto 2 Retire el panel preperforado del ventilador del panel usando un destornillador Ver Fig 9 Instale el ventilador en el panel trasero del calefactor usando los cuatro tornillos proporcionados NOTA Asegúrese de que el interruptor oscilante esté colocado en la esquina superior derecha Ver Fig 10 3 Este vent...

Страница 43: ...l borde de la mesa 3 Sujete las patas de soporte al calefactor usando los tornillos de las patas de soporte Fig 13 Nota Si el calefactor va a ser instalado directamente sobre alfombra baldosa u otro material combustible que no sea piso de madera el aparato debe ser instalado sobre un y panel metálico o de madera que se extienda en la anchura y profundidad completas del aparato 3 Una vez en su posi...

Страница 44: ...que solamente el último agujero en cada extremo del soporte de montaje Inserte 2 tornillos para madera ST4 8 45 16 en total de a través de estos agujeros solamente 3 Retire la cinta y el soporte de montaje de la pared Instalación del soporte de montaje en la pared Nota Los soporte de expansión los tornillos para made ra ST4 8 45 16 y los Separador de colgador de pared están en el paquete de herraj...

Страница 45: ... y en los soportes de expansión 7 Apriete los expansión tornillos del soporte ST4 8 15 16 hasta que el soporte de montaje esté sujetado firmemente en la pared 8 Compruebe que el soporte esté seguro antes de montar el calefactor Instalación de separadores de colgador al calefactor ADVERTENCIA No instalar apropiadamente los separadores de colgador de pared puede resultar en daños a la propiedad lesi...

Страница 46: ...ón de la línea de gas es mayor la unidad no funcionará y podrían ocurrir daños al regulador del calefactor PRECAUCIÓN Nunca conecte el calefactor directamente a un suministro de PL Este calefactor requiere un regulador externo no suministrado Instale el regulador externo entre el calefactor y el suministro de gas PRECAUCIÓN Evite dañar el regulador Sostenga el regulador de gas con una llave cuando...

Страница 47: ...es de prueba mayores de 1 2 PSIG 3 5kPa El aparato y su válvula de gas principal deben estar desconectados del sistema de tubería de suministro de gas durante cualquier prueba de presión de ese sistema a presiones de prueba mayores de psi 3 5 kPa Presión de prueba del suministro de gas igual o mayor que 1 2 PSIG 3 5kPa El aparato debe aislarse del sistema de tubería de suministro de gas cerrando s...

Страница 48: ...No toque ningún interruptor eléctrico no use ningún teléfono en su edificio LLame de inmediato a su proveedor de gas del teléfono de un vecino Siga las instrucciones del proveedor de gas Si no puede contactar a su proveedor de gas llame al Cuerpo de Bomberos C Use solamente su mano para presionar o girar la perilla de control del gas Nunca use herramientas Si la perilla no se puede presionar o gir...

Страница 49: ...oprimida presione el encendedor hasta que el piloto se encienda El piloto es visible centrado abajo de las placas detrás de la rejilla frontal Ver Fig 24 7 Mantenga oprimida la perilla de control durante 30 segundos después de que el piloto encienda Suelte la perilla de control Nota Si el piloto se apaga repita los pasos 3 al 7 Espere 1 minuto antes de intentar encender el piloto de nuevo Si despu...

Страница 50: ...CCIÓN DE LOS QUEMADORES Revise diariamente el patrón de la llama cuando esté en uso y al menos una vez al año por una agencia de servicio calificada PATRÓN DE LA LLAMA DEL PILOTO La Figura 26 muestra un patrón correcto de la llama del piloto La Figura 27 muestra un patrón incorrecto de la llama del piloto La llama incorrecta del piloto no está tocando el termopar Esto hará que el termopar se enfrí...

Страница 51: ... altas con la perilla de control adjustada a llama alta 5 1 2 de la altura de vidrio 1 2 de la altura de vidrio El tercio superior de la llama puede ser de color amarillo brillante cuando se opera con propano Cuando este calentador está configurado para su uso con gas propano el tercio superior de la llama puede ser de color amarillo brillante Cuando este calentador está configurado para su uso co...

Страница 52: ... comprimido en una lata siga las instrucciones en la lata Si no sigue las instrucciones en la lata podría dañar el ensamblaje del piloto PRECAUCIÓN Nunca use un alambre aguja u objeto similar para limpiar el ODS piloto Esto puede dañar la unidad del ODS piloto 1 Apague la unidad incluyendo el piloto Deje que la unidad se enfríe al menos durante 30 minutos 2 Retire 4 tornillos 2 tornillos en cada l...

Страница 53: ...encendedor no está conectado al cable del encendedor 4 El cable del encendedor está aplastado o húmedo 5 Cable del encendedor dañado 6 Encendedor o módulo de ignición malo 7 Batería mala 1 Reemplace el ODS 2 Reemplace el ODS 3 Reemplace el cable del encendedor 4 Libere el cable del encendedor si está aplastado por algún metal o tubería Mantenga seco el cable del encendedor 5 Reemplace el cable del...

Страница 54: ...de gas Ignición retrasada del los quema dor es 1 La presión del distribuidor es de masiado baja 2 El orificio del quemador está obstruido 1 Llame a su proveedor de gas 2 Limpie el quemador ver Cuidado y Manteni miento página 22 o llame a servicio al cliente Retorno de llama del quemador durante la combustión 1 El orificio del quemador está obs truido o dañado 2 El quemador está dañado 3 El regulad...

Страница 55: ...iloto ver Cuidado y man tenimiento página 22 Hay olor a gas inclu so cuando la perilla de control está en la posición OFF 1 Fuga de gas Ver Declaración de advertencia en la parte su perior de la página 23 2 La válvula de control está defectuosa 1 Localice y corrija todas las fugas ver Revisión de las conexiones de gas página 17 2 Llame a Servicio al Cliente Se advierte humedad condensación en las ...

Страница 56: ... a AUTO 3 El motor del ventilador está malo 1 La carcasa o las aspas del ventilador están sucias 2 La rotación del ventilador está bloqueada 3 Ventilador defectuoso 1 Ver Limpieza del ventilador página 22 2 Compruebe que el cableado no esté en el paso del ventilador 3 Reemplace el ventilador 1 Compruebe que el ventilador esté conectado y ajustado a MAN o AUTO 2 Espere de 5 a 10 minutos para que el...

Страница 57: ...0221 GN Ensamble del Regulador 1 GR 130 10K GR 130 20K GR 130 30K PL Ensamble del Regulador 1 GR 130A 10K GR 130A 20K GR 130A 30K Soporte de Retención del Panel de Cristal Panel de Cristal 1 AQ000164 AQ000148 AQ000180 Paquete de Hardware 1 AQ000233 AQ000233 AQ000233 Orificio de Reemplazo GN 1 BF10K NG BF20K NG BF30K NG Orificio de Reemplazo PL 1 BF10K LP BF20K LP BF30K LP Ensamble del ventilador M...

Страница 58: ...28 ...

Страница 59: ..._________ PRECIO PAGADO __________________ Por favor tómese un minuto para darnos sus respuestas a las siguientes preguntas Todas las respuestas serán usadas únicamente para investigación de mercado y serán mantenidas en estricta confidencialidad Quién decidió principalmente esta compra Hombre Mujer 18 24 25 39 40 59 60 y mayor Propósito de la compra _______________________________________________...

Страница 60: ...sus registros Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www ghpgroupinc com GHP GUARDE ESTA TARJETA GHP Group Inc 6440 W Howard St Niles I...

Отзывы: