PREPARING FOR INSTALLATION

Before beginning assembly or operation of the product, make sure all parts are present.
Compare parts with package contents list. If any part is missing or damaged, do not attempt
to assemble, install or operate the product. Contact customer service for replacement parts.

UNPACKING

1. Remove heater from carton.

2. Remove all protective packaging applied to heater for shipping

3. Verify all contents are present. 

 

NOTE:

 Support Leg Screw (M4*15) (Select Models), Wood Screw (ST4.8*45-16),

     Expansion Bracket Screw(ST4.8*15-16), and Expansion Bracket come with (2) extra each.

4. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you  
  bought the heater. 

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces

approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (.3 Kw) of gas input

per hour. An unvented room heater is intended as a supplemental heater rather than a primary heat 

source. In most supplemental heat applications, the water vapor does not create a problem. 

In most applications, the water vapor enhances the low humidity atmosphere experienced during 

cold weather.

The following steps will help ensure that water vapor does not become a problem:

1. Be sure the heater is the proper size for the application, including adequate combustion air and 

  circulation air.

2. If there is high humidity, a dehumidifier may be used to help lower the water vapor content 

  of the air.

3. Do not use an unvented room heater as the primary heat source.

Expansion
Bracket x 4

Expansion Bracket

Screw (ST4.8*15-16) x 4

Wall Hanging 

Spacer x 2

Wood Screw 

(ST4.8*45-16) x 4

Expansion Bracket

Tool x 1

Wall Hanging 

Spacer Screw

(M4*25) x 2

Wall Mounting 

Bracket x 1

Support Leg Screw

(M4*15) x 4

(Select Models)

Support Leg x 2
(Select Models)

AAA Battery x 1

Содержание BF10PTDG/PMDG

Страница 1: ...ice must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate...

Страница 2: ......

Страница 3: ...00 20 000 MIN BTU 8 000 16 000 Fuel Type Propane Propane Ignition Electronic Push Button Electronic Push Button Manifold Pressure 10 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Min...

Страница 4: ...ect Models 120V 60Hz 18W 0 15A SERIES BF10NTDG NMDG BF20NTDG NMDG MAX BTU 10 000 20 000 MIN BTU 5 000 10 000 Fuel Type Natural Gas Natural Gas Ignition Electronic Push Button Electronic Push Button Ma...

Страница 5: ...mmable material on or near the appliance Never place any objects on the heater WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies This applianc...

Страница 6: ...hrough 25 4 Keep all air openings in front top and bottom of heater free of objects and debris to ensure adequate air for proper combustion 5 If heater shuts off do not relight until you have provided...

Страница 7: ...heater State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room...

Страница 8: ...proximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplement...

Страница 9: ...unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are...

Страница 10: ...U hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct v...

Страница 11: ...fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or...

Страница 12: ...e support legs Select Models WARNING Maintain the minimum clearances shown in See Fig 3 If you can provide greater clearances from floor ceiling and joining wall Fig 3 Mounting clearances as viewed fr...

Страница 13: ...connected from gas supply and removed from wall before installing fan accessory Contact a qualified service person to do this 2 Remove fan knock out panel using a screwdriver See Fig 9 Attach Fan to t...

Страница 14: ...e table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table e...

Страница 15: ...wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wood screws ST 8 45 16...

Страница 16: ...th expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is fi...

Страница 17: ...line pressure is higher the unit will not work and heater regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied In...

Страница 18: ...3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pres...

Страница 19: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 ST...

Страница 20: ...ait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call your service technician or gas supp...

Страница 21: ...to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic OPERATION INSPECTING BURNERS Check pilot flame pattern daily when in use and at least yearly by a qualified service agency PILOT FLAM...

Страница 22: ...ored flame may be caused by airborne dust dander pet hair etc Additionally an excess amount of Mercaptane in the fuel can result in an orange or yellow colored flame The upper third of flame may be br...

Страница 23: ...on t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Remove 4 screws 2 screws on each side...

Страница 24: ...de is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor or ignition mod ule 7...

Страница 25: ...tomer service 4 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Mainte nance p...

Страница 26: ...r 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 23 2 Control valve is defective 1 Locate...

Страница 27: ...dels 1 There is no power to the fan 2 Fan is set to AUTO 3 Fan motor is bad 1 Fan housing or blades are dirty 2 Fan rotation is blocked 3 Defective fan 1 See Cleaning Fan page 22 2 Verify wiring is no...

Страница 28: ...rmostatic Gas Valve 1 AQ000025A AQ000025B AQ000025C 6 Manual Gas Valve 1 AQ000227 AQ000228 AQ000229 7 1 NG Regulator Assembly 1 AQ000073D AQ000073B AQ000073 7 2 LP Regulator Assembly 1 AQ000073E AQ000...

Страница 29: ...______________________________________ TYPE OF STORE __________________________ CITY STATE WHERE PURCHASED ______________________________________________ PRICE PAID _______________________ Please Take...

Страница 30: ...ds SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 828...

Страница 31: ...or accionado por gas no ventilado Utiliza aire ox geno de la habitaci n en la cual est instalado Deben tomarse medidas para una combusti n y aire de ventilaci n adecuados Consulte la secci n Aire para...

Страница 32: ...i n del distribuidor 10 pulg de columna de agua 10 pulg de columna de agua Presi n de gas de entrada M ximo 14 pulg de columna de agua 14 pulg de columna de agua M nimo Para fines de ajuste de entrada...

Страница 33: ...de columna de agua 14 pulg de columna de agua M nimo Para fines de ajuste de entrada 6 pulg de columna de agua 6 pulg de columna de agua Dimensiones pulg Alto x Ancho x Di metro La altura incluye las...

Страница 34: ...ELIGRO DE ENVENENAMIENTO CON MON XIDO DE CARBONO Las se ales tempranas de envenenamiento con mon xido de carbono se parecen a la gripe con dolores de cabeza mareos o n usea Si tiene estas se ales el c...

Страница 35: ...as de aire en el frente parte superior y parte inferior del calentador libres de objetos y desechos para asegurar aire adecuado para una combusti n apropiada 5 Si el calefactor se apaga no lo encienda...

Страница 36: ...rio para el funcionamiento del calentador Estado de Massachusetts La instalaci n debe ser hecha por un fontanero o t cnico de gas calificado en la Commonwealth de Massachusetts Los vendedores de calef...

Страница 37: ...aproximadamente 1 onza 30 mL de agua por cada 1 000 BTUs 0 3 Kw de entrada de gas por hora Un calefactor no ventilado de habitaci n est previsto como un calefactor comple mentario en lugar de una fuen...

Страница 38: ...on puertas son consideradas una parte del espacio no confinado Este calefactor no deber ser instalado en un espacio confinado o construcci n inusualmente herm tica a menos que se tomen medidas para un...

Страница 39: ...Ejemplo Le os de calentador a gas __________BTU hr Calentador de agua a gas 30 000 BTU hr Otros aparatos a gas ____BTU hr Calefactor de tiro natural 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr...

Страница 40: ...ambi n puede retirar la puerta de la habitaci n contigua ver opci n 3 Fig 1 Siga el C digo Nacional de Gas Combustible NFPA 54 ANS Z223 1 Aire para la combusti n y ventilaci n para el tama o requerido...

Страница 41: ...STIBLES Siga las siguientes intrucciones con mucho cuidado Este calefactor se puede montar en la pared o en el piso usando las patas soportes Modelos seleccionados ADVERTENCIA Mantenga los espacios li...

Страница 42: ...alar el accesorio del ventilador Contacte a una persona de servicio calificada para hacer esto 2 Retire el panel preperforado del ventilador del panel usando un destornillador Ver Fig 9 Instale el ven...

Страница 43: ...borde de la mesa 3 Sujete las patas de soporte al calefactor usando los tornillos de las patas de soporte Fig 13 Nota Si el calefactor va a ser instalado directamente sobre alfombra baldosa u otro mat...

Страница 44: ...ue solamente el ltimo agujero en cada extremo del soporte de montaje Inserte 2 tornillos para madera ST4 8 45 16 en total de a trav s de estos agujeros solamente 3 Retire la cinta y el soporte de mont...

Страница 45: ...y en los soportes de expansi n 7 Apriete los expansi n tornillos del soporte ST4 8 15 16 hasta que el soporte de montaje est sujetado firmemente en la pared 8 Compruebe que el soporte est seguro antes...

Страница 46: ...n de la l nea de gas es mayor la unidad no funcionar y podr an ocurrir da os al regulador del calefactor PRECAUCI N Nunca conecte el calefactor directamente a un suministro de PL Este calefactor requi...

Страница 47: ...de prueba mayores de 1 2 PSIG 3 5kPa El aparato y su v lvula de gas principal deben estar desconectados del sistema de tuber a de suministro de gas durante cualquier prueba de presi n de ese sistema...

Страница 48: ...ne el aparato y reemplace cualquier pieza del sistema de control y cualquier control del gas que haya estado bajo el agua INSTRUCCIONES DE ENCENDIDO CONTROL MANUAL DEL GAS 1 ALTO Lea la informaci n de...

Страница 49: ...placas detr s de la rejilla frontal Ver Fig 24 7 Mantenga oprimida la perilla de control durante 30 segundos despu s de que el piloto encienda Suelte la perilla de control Nota Si el piloto se apaga...

Страница 50: ...Fig 25 Fig 25 Posici n de la perilla de control Manual Termost tico OPERACI N INSPECCI N DE LOS QUEMADORES Revise diariamente el patr n de la llama cuando est en uso y al menos una vez al a o por una...

Страница 51: ...altas con la perilla de control adjustada a llama alta 5 1 2 de la altura de vidrio 1 2 de la altura de vidrio El tercio superior de la llama puede ser de color amarillo brillante cuando se opera con...

Страница 52: ...usa aire comprimido en una lata siga las instrucciones en la lata Si no sigue las instrucciones en la lata podr a da ar el ensamblaje del piloto PRECAUCI N Nunca use un alambre aguja u objeto similar...

Страница 53: ...l encendedor no est conectado al cable del encendedor 4 El cable del encendedor est aplastado o h medo 5 Cable del encendedor da ado 6 Encendedor o m dulo de ignici n malo 7 Bater a mala 1 Reemplace e...

Страница 54: ...e gas Ignici n retrasada del los quema dor es 1 La presi n del distribuidor es de masiado baja 2 El orificio del quemador est obstruido 1 Llame a su proveedor de gas 2 Limpie el quemador ver Cuidado y...

Страница 55: ...iloto ver Cuidado y man tenimiento p gina 22 Hay olor a gas inclu so cuando la perilla de control est en la posici n OFF 1 Fuga de gas Ver Declaraci n de advertencia en la parte su perior de la p gina...

Страница 56: ...a AUTO 3 El motor del ventilador est malo 1 La carcasa o las aspas del ventilador est n sucias 2 La rotaci n del ventilador est bloqueada 3 Ventilador defectuoso 1 Ver Limpieza del ventilador p gina 2...

Страница 57: ...most tica 1 AQ000025A AQ000025B AQ000025C 6 V lvula Manual de Gas 1 AQ000227 AQ000228 AQ000229 7 1 GN Ensamble del Regulador 1 AQ000073D AQ000073B AQ000073 7 2 PL Ensamble del Regulador 1 AQ000073E AQ...

Страница 58: ...28...

Страница 59: ...______________ PRECIO PAGADO __________________ Por favor t mese un minuto para darnos sus respuestas a las siguientes preguntas Todas las respuestas ser n usadas nicamente para investigaci n de merca...

Страница 60: ...us registros Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Av...

Отзывы: