Belt-Tracking Adjustment
All Dymax
WIDECURE
conveyors are factory adjusted to provide proper tracking of the belt. Should further adjustments become
necessary, this is done via two adjustment bolts located at the input end of the conveyor (Figure 17). To adjust tracking, simply
tighten the side to which the belt is tracking.
NOTE: Do not over tighten the belt. This will lead to accelerated degradation of the belt. The belt should be only tight enough as to
ensure it does not drag on the underside of the conveyor and machine.
Electrical Case Fan Filter Replacement
1.
The filter used in the electrical cabinet of the
WIDECURE
conveyor is a Hoffman Replacement Filter,
part #10100061 and can be obtained through
2.
Turn off the conveyor and shut down the main power supply breaker to remove electrical power at the
WIDECURE
system.
3.
On the left side of the conveyor, remove the blue trim corners on the front and rear of the unit. They are magnetically held to
the conveyor (Figure 18).
4.
Remove the black lower panel on the left side of the conveyor, just below the belt, (Figure 18) by unscrewing the Phillips-
head screws. This will expose the lamp power supply and blower system
(Figure 19).
Figure 18. Remove Blue Corner Trim and Black Panel on Left Side of System
Remove
corner trim
Remove corner trim
Remove panel