17
Dymax Edge-Carry Conveyor User Guide
10.
Attach the Cables leading from the back of the conveyor to the J-105B and J-106 Receptacles of the
Master Power Supply. These Cables are labeled to aid in assembly.
11.
For dual Fusion Lamps, install the Jumper Plug in J-105A of the Slave Power Supply. Connect the Jumper
Cable between J-107 of the Master Power Supply and J-106 of the Slave Power Supply. (Figure 24)
Figure 24. Power Supplies
12.
Connect the other end of the Irradiator Cable to the J-103 and J-104 Receptacles of the Power Supply(ies).
13.
Connect the Power Cord to the back of the Power Supply and to a 208-240 volt (as appropriate) Power
Source. For Dual Fusion units, the J-105A Jumper must be installed in the Slave Power Supply (Figure 25).
Figure 25. Power Supplies
14.
Plug in the Conveyor and turn it on. When the Conveyor is operating and the Chain is in motion, turn the
Power Supply on by closing the Breakers (Figure 26) on both of the Power S
upply’s
Front Panels.
15.
Turn the Irradiators on by pressing the Lamp On Button (Figure 27) of the Master Power Supply. Both the
Master and the Slave Power Supplies will go through a warm-up cycle. The Blower inside the Irradiators
will turn on and the Lamps will ignite. The Lamps reach full intensity within five seconds after ignition.
Figure 26. Breakers
Figure 27. Lamp On Button
16.
Your UVCS-F Conveyor is now ready for operation.