![dymax EC Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/dymax/ec-series/ec-series_user-manual_2546031008.webp)
8
Dymax EC-Series Flood Lamps for UVCS Conveyors User Guide
System Components
ECE 2000
The Dymax 2000-EC Flood Lamp is a general purpose UV light-
curing system with an effective curing area of approximately 8"
x 8" [20.3 cm x 20.3 cm]. The 2000-EC Flood Lamp is cooled by
air flow through the Reflector from the Conveyor’s Ventilation
System.
ECE 5000
The Dymax 5000-EC Flood Lamp is a general purpose UV light-
curing system with an effective curing area of approximately 5"
x 5" [12.7 cm x 12.7 cm]. Comparatively, it provides more than
twice the output intensity of a Dymax 2000-EC Flood Lamp for
faster curing capability and the additional ability to cure
conformal coating resins.
Solid-State Power Supply
This power supply allows external electrical inputs and provides
power to the Bulb located in the Lamp/Reflector Assembly
Housing. The Power Supply contains the On/Off Power Switch
and Hour Meter that are located on the front panel. The Power
Supply also houses its own Cooling Fans and power distribution
for optional accessories. The rear panel has an integrally fused
AC Power Receptacle and an 8-Pin Female circular connector
for supplying power to the Lamp Housing Assembly.
The solid-state Power Supply yields reliable and stabilized
voltage in virtually any electrical system in the world. Other
than ensuring a properly configured plug is employed, no other
adjustment of settings is required. The Power Supply also
conditions the electrical power to the Bulb providing longer,
more reliable Bulb life.
This unit is RoHS Compliant.