dymax ACCU-CAL 50-LED Скачать руководство пользователя страница 4

USE R   GUI DE

 

|

 

ACC U -

CAL ™  5 0

-L E D  R ADI OME T E R

Introduction 

The enclosed ACCU-

CAL™ 50

-LED Radiometer was 

developed and manufactured by the Dymax team, 
driven by a desire to best serve your needs. Before 
shipping, your ACCU-

CAL™ 50

-LED Radiometer was 

calibrated and tested against standard LED light 
sources to ensure accurate performance. 

The operation of this radiometer in conjunction with an 
LED light-curing system will maximize safety and user-
friendly performance and provide optimum yield of your 
technological process. 

Therefore, we encourage you to read, understand, and 
follow all safety and operating instructions and 
recommendations compiled in this and other related 
manuals prior to setting up and operating this 
instrument and any associated light-curing systems. 

If you encounter a problem, have any questions, or 
would like to help us with your suggestions or 
recommendations, please contact our Technical or 
Customer Service Departments at 860-482-1010. 
Trained Dymax professionals are standing by to serve 
you.   

Par conséquent, nous vous encouragez a lire, 
comprend, et suivre tout sécurité et instructions 

d’opération et conseillations rédiger dans cette et autre 

manuels etablir un lien avant de mettre en place et de 
faire marcher cette nouveau système de lampe de 
tache ou cettes composants individuel.  

Si vous rencontrez un problème, avait n’importe de 

questions, ou si vous voudrez de nous aider avec tes 

suggestions ou conseillations, s’il vous plait contacte 

notre departements technique ou service client à 860-
482-1010. Dymax formé professionals attendre a vous 
servir.  

Safety 

General Safety 

Before continuing, please read the following chapters of 
this manual for safety recommendations and installation, 
running, and troubleshooting instructions. 

 

CAUTION!

  Always wear protective goggles or 

a face shield when working near the front of 
any unit which emits UV light!  The rear of 
some units also emits stray UV light.  

WARNING!

  Always observe safety 

requirements! 

PRÉ-CAUTION!

 

Toujours faisez de l’usa

ge des 

lunettes de protection ou protéger de visage 
march

e près du devant d’élément!

 

PRÉ-CAUTION!

 Risque de décharge électrique 

quand le couvert est enlever! 

ACHTUNG!

  Tragen Sie immer eine 

Sicherheitsbrille oder einen Gesichtsschutz, 
wenn Sie nahe an der UV Lichtquelle arbeiten. 
Die Rückseite des Gerätes emittiert gestreutes 
UV Licht! 

WARNHINWEIS! 

Bitte beachten Sie immer die 

Sicherheitshinweise! 

Safety  

The ACCU-

CAL™ 50

-LED Radiometer is designed to be 

used in conjunction with Dymax LED curing equipment 
that is properly set up, with components correctly 
connected, and operated in accordance with relevant 
instructions. 

Safety Recommendations 

 

When working with UV or visible light sources, 
use goggles (provided) or a face shield approved 
for UV protection to protect your eyes. 

 

Long-sleeved shirts or a lab coat are 
recommended to protect the arms, and use of UV 
opaque gloves will protect the hands. 

     

Sécurité 

 

L’équipment ètre concu pour ètre utilisé correctement 

constituer, avec composants brancher correctement, et 
marché en conformément avec instructions important. 
Le plan étais developer pour render au maxime 
opérateur sécurité et minimiser expositon à ultraviolette.  

 

 

Содержание ACCU-CAL 50-LED

Страница 1: ...ACCU CAL 50 LED LED Radiometer User Guide ...

Страница 2: ...pection and increase throughput System designs enable stand alone configuration or integration into your existing assembly line Please note that most dispensing and curing system applications are unique Dymax does not warrant the fitness of the product for the intended application Any warranty applicable to the product its application and use is strictly limited to that contained in the Dymax stan...

Страница 3: ...t Overview 5 Installation 6 Unpacking and Inspecting Your Shipment 6 Parts List Spot Line Array Configuration 6 Parts List Flood Configuration 6 Operation 7 Testing a Flood Lamp System 7 Testing Spot Lamp Systems 8 Testing the BlueWave QX4 10 Maintenance 12 Spare Parts and Accessories 13 Specifications 13 ...

Страница 4: ...ts technique ou service client à 860 482 1010 Dymax formé professionals attendre a vous servir Safety General Safety Before continuing please read the following chapters of this manual for safety recommendations and installation running and troubleshooting instructions CAUTION Always wear protective goggles or a face shield when working near the front of any unit which emits UV light The rear of s...

Страница 5: ...The ACCU CAL 50 LED Radiometer is a microprocessor based measurement instrument designed to measure curing energy radiation in the range of 350 450 nm The ACCU CAL 50 LED uses two AA batteries Environmental Considerations Optical measurement instruments are sensitive to extremes in environmental conditions like high temperature humidity and contamination Protect the device and its detector s from ...

Страница 6: ...those listed below If parts are missing contact your local Dymax representative or Dymax Customer Support to resolve the problem Figure 2 ACCU CAL 50 LED Radiometer PN 40505 for Spot Line Flood Lamps Figure 3 ACCU CAL 50 LED Radiometer PN 40519 for Flood Lamps Only Parts List Spot Line Array Configuration ACCU CAL 50 LED Radiometer ACCU CAL 50 LED Radiometer User Guide 3 mm 5 mm 8 mm Lightguide Ad...

Страница 7: ...e Light Source button to select the light source being measured Repeatedly press the button until Flood Lamp appears on the top line of the display Figure 5 5 Press and release the Mode button to select the operating mode Repeatedly press the Mode button until the mode you desire appears on the second line of the display The different operating modes are Peak Intensity Shows the highest intensity ...

Страница 8: ... and the second line displays the mode 9 Press and release the Light Source button to select the light source being measured For spot lamps use the lightguide setting Repeatedly press the Light Source button until the correct lightguide size appears on the top line The options are 3 mm Lightguide For use when measuring energy at the end of a 3 mm lightguide 5 mm Lightguide For use when measuring e...

Страница 9: ...Mode button to select the operating mode Repeatedly press the Mode button until the mode you desire appears on the second line of the display The different operating modes are Peak Intensity Shows the highest intensity in mW cm2 seen by the detector during the measurement and stores that value in the display Intensity Shows the intensity in mW cm2 at the detector during the measurement This is a d...

Страница 10: ...sensor to energy emissions for more than 15 seconds Testing the BlueWave QX4 1 Attach the detector to the radiometer Figure 15 2 Attach the BlueWave QX4 optic adapter to the detector Figure 16 using the two 2 mm screws provided Note The optical adapter and optometer are calibrated as a set so they are not interchangeable among other similar type radiometers 3 Insert the LED head into the optic ada...

Страница 11: ...d 8 mm Spot For use when measuring a BlueWave QX4 LED head with the 8 mm focus lens installed Figure 18 Spot Mode Screens Shown in Peak Intensity Mode 7 Press and release the Mode button to select the operating mode The different operating modes are Peak Intensity Shows the highest intensity in mW cm2 seen by the detector during the measurement and stores that value in the display Intensity Shows ...

Страница 12: ...service is available through Dymax Customer Service or Dymax Product Repair Change the batteries when a low battery warning is received The ACCU CAL 50 LED uses two AA type batteries The battery compartment is on the back of the instrument Figure 19 Battery Compartment Closed Open Keep the detector head s sensing element clean and free of contaminants The detector head may be cleaned with a clean ...

Страница 13: ...558 5 mm Lightguide Adapter 39557 3 mm Lightguide Adapter 39556 Line Array Adapter 43364 2 mm Hex Wrench 38656 2 mm Screws 38881 Specifications Property Specification Power Two AA size batteries Display LCD Graphic Display 97x 32 Pixel Display area 0 56 in x 1 41 in 14 3 mm x 35 8 mm Spectral Range 350 450 nm Detector Interface 9 Pin MDSM9 socket 4 inputs Measurement Ranges Four modes of operation...

Страница 14: ...nt may void your warranty benefits The use of aftermarket replacement parts not supplied or approved by Dymax Corporation will void any effective warranties and may result in damage to the equipment IMPORTANT NOTE DYMAX CORPORATION RESERVES THE RIGHT TO INVALIDATE ANY WARRANTIES EXPRESSED OR IMPLIED DUE TO ANY REPAIRS PERFORMED OR ATTEMPTED ON DYMAX EQUIPMENT WITHOUT WRITTEN AUTHORIZATION FROM DYM...

Страница 15: ...USER GUIDE ACCU CAL 50 LED RADIOMETER 15 ...

Страница 16: ...hat contained in Dymax Europe GmbH s General Terms and Conditions of Sale published on our website Dymax Europe GmbH does not assume any responsibility for test or performance results obtained by users It is the user s responsibility to determine the suitability for the product application and purposes and the suitability for use in the user s intended manufacturing apparatus and methods The user ...

Отзывы: