Model 400 Dispensing Valve User Guide
11
Troubleshooting
Table 1. Troubleshooting Chart for Model 400 Dispensing Valve
Problem
Possible Cause
Corrective Action
Valve does not
dispense anything
The fluid pressure is too
low
Increase the fluid pressure above 15 psi
Material is cured in the
fluid section
Disassemble and clean the valve
Air pressure is too low
Adjust air pressure accordingly
Dispense rate too
fast
The fluid pressure is set
too high
Decrease the fluid pressure
The dispense tip gauge is
too large
Replace the dispense tip with a smaller
size tip
Dispense rate too
slow
The fluid pressure is set
too low
Increase the fluid pressure
The dispense tip gauge is
too small
Replace the dispense tip with a larger
gauge
Air bubbles in
fluid
The valve is not properly
purged
Point the valve up and cycle it until
any air bubbles are removed
There is a problem with
the material reservoir and
fluid delivery system
Diagnose and repair
Fluid pressure is too high
Adjust fluid pressure accordingly
Material leaks
from Valve Tip
Air bubbles are trapped in
the fluid section of the
body or in the dispense tip
Point the valve up and cycle it until
any air bubbles are removed
Содержание 400