INSTALLATION CONSIDERATIONS

9

Installation and Assembly Considerations
◆ 

Connect the suction and discharge ports of the pump with a hose or flexible pipe to avoid damage caused by vibration of the pump. Never step on

            the diaphragm pump or use other methods to apply weight to the pump body, or suspend the pump. Otherwise, there is a danger of personal injury 
            or equipment failure.
◆ 

The suction head of the inlet should be less than six meters (For water). 

◆ 

The direction of the pipe (inlet and outlet) can be turned, but please pay attention to the O-ring when disassembling and installing it and locking 

            the pipe well to prevent leakage.
◆ 

We suggest that you can install the air filter, regulator, and lubricator (FRL) on the air inlet of the pump.

Adjustments for connection of high air pressure
◆ 

The air source of the air compressor is connected to the air inlet of the pump through the air pressure hose. It is operated by the air filters. The

            supply air pressure used shall not exceed the maximum operating pressure.
◆ 

We suggest that you can install the air regulator on the air inlet of the pump. The supply air pressure used shall not exceed the maximum operating 

            pressure.
◆ 

Check the air filter at the air pressure input regularly to drain the accumulated wastewater and impurities. If too much wastewater is introduced

            into the pump body, the wastewater and lubricating oil will emulsify and affect the lubrication of the parts, or block the pores, thereby affecting 
            the operation performance of the pump or causing malfunction.
Air Line Moisture
◆ 

Water in the compressed air supply can create problems such as icing or freezing of the exhaust air, 

           causing the pump to cycle erratically or stop operating. Water in the air supply can be reduced by using 
           a point-of-use air dryer to supplement the user’s air-drying equipment. This device removes water from
           the compressed air supply and alleviates the icing or freezing problems.
Air cycle
◆ 

To start the pump, the air compressor provides air pressure to the body of the cylinder base of the pump,

           flowing into the Sequential and Air Valve through the air hole. It drives the diaphragm and shaft doing power conversion. 
           During the conversion process, the deflated gas is discharged through the silencer. Please make sure that the exhaust gas 
           pipeline is smooth to avoid the blockage of the pump.
Liquid delivery process
◆ 

When the pump is used for materials that tend to settle out or solidify when not in motion, the pump should be flushed

            after each use to prevent damage. (Product remaining in the pump between uses could dry out or settle out. This could 
            cause problems with the diaphragms and check valves at the restart.) In freezing temperatures, the pump must be 
            completely drained between uses in all cases.

Содержание DS03-A

Страница 1: ...DS03 A OPERATING MANUAL ...

Страница 2: ...e and Liquids Serviceability Specification 3 Material and Temperature Range 4 Exploded View Drawing 5 Screws Torque Guide 6 Dimensions 7 Important Safety Information 8 Installation Considerations 9 Installation Instructions 10 FAQ 11 Warranty Instructions 12 ...

Страница 3: ...pylene add Bolivian filament ent Current specificalion Size Wetted Body Center Body Pupe Type Diaphragm Ball cover Ball Ball seat Edition 03 3 8 A Aluminum ADC12 A380 A Aluminum T Conter U UPE A Aluminum S S S 316 S Stainless Steel 01 D Doule out in T PTFE TFM E PE T PTFE T PTFE 02 O Santoprene O Santoprene E PE ...

Страница 4: ...nyl Chloride Ammonia Asphalt Sulfuric Acid Chromic Acid Electroplate Solu on High Temperature Sauce Chili Sauce Coal Oil Vola le Oil Carrier Oil Immiscible Fluids Freezing Mixture Degreasing Agent Methylene Chloride Jam Juice Ace c Acid Leavan Slops Balsam Olive Oil Defoamer DSXX SAX OXSO X Glaze Po ery Clay Thick Liquid Bolivian Filament Note Depending on the density temperature concentration and...

Страница 5: ... thermoplas c vulcanizates TPVs are high performance elastomers which offer manufacturing flexibility ease of processing and durability It combines the characteris cs of vulcanized rubber with the processing proper es of thermoplas cs 40 135゚C Polyethylene PE The thermoplas c resin is made by polymeriza on of ethylene which is also includes a polymer of ethylene and a small amount of the polyethylen...

Страница 6: ... 28 20 28 ShaftCover B Set 1 A16 20 28 21 29 AxisSwitch Set 1 A16 21 29 22 ShaftOfDiaphragm 1 PA000114 23 Oring 2 PB000001 24 Oring 2 PD000001 32 HexagonScrew 4 PC000005 33 AbnormalOring 1 PD000140 34 AbnormalOring 1 PD000139 35 BodyOfSequential 1 PA000102 36 PistonOfAirValve 1 PA000141 37 Oring 1 PDAP0023 38 Oring 2 PDR00016 39 StartingCopperLatch 1 PA000112 40 CoverOfSequential A 1 PD000080 41 C...

Страница 7: ...gf m 9 8066 981 100000 100 86 8 7 233 1 lbf in 0 113 11 3 1150 1 152 0 0115 0 083 1 lbf 1 355 136 13800 13 83 0 138 12 Unit Imperial Unit Tension to Torque Conversion SI Gravity Unit Posi on Name Torque Values kgf cm Locked with 46 1 4 Hexagon Bung 60 65 MAX Locked with 46 3 8 Hexagon Bung 155 160 MAX 45 M6 Hexagon Screw 95 110 Max 12 M8 Steel Hexagon Screw 90 100 Max 3 M6 Hexagon Screw 110 130 Ma...

Страница 8: ...7 DIMENSIONS 141 103 183 80 100 150 Air Inlet 1 4 215 178 Fluid Outlet 3 8 Fluid Inlet 3 8 ...

Страница 9: ...8 IMPORTANT SAFETY INFORMATION ...

Страница 10: ...es If too much wastewater is introduced into the pump body the wastewater and lubricating oil will emulsify and affect the lubrication of the parts or block the pores thereby affecting the operation performance of the pump or causing malfunction Air Line Moisture Water in the compressed air supply can create problems such as icing or freezing of the exhaust air causing the pump to cycle erraticall...

Страница 11: ...le connection Pipe Connection Style Optional Pipe Connection Style Optional Flexible connection Gauge Gauge Shut Off Valve Shut Off Valve Drain Port Drain Port Discharge Suction Air inlet Air shut Off Valve Modular Type F R L Unit INSTALLATION INSTRUCTIONS ...

Страница 12: ...mp whether lubricates sufficient or not Please clean up the dirty parts and relubrication It is recommended to add lubricating oil to the air pressure inlet pipeline every half year don t exceed 10ml each time c Sequential valve abnormal If the deterioration of the sequential if it is worn please change it d Compressed Air Lines Freezing The Slithery Mass Valve 53 might be frozen because of low te...

Страница 13: ...of the original quality of the product we will change a new one for you Improper use e g Falling Attacked Liquid input etc or abnormal operating conditions e g Flood Fire Earthquake Lightning strike Typhoon etc these damages are not covered by the warranty Improper installation self modifying wear and tear caused by not transporting in accordance with machine regulations Accident or defect caused ...

Отзывы: