broken,(open) console can’t receive
the speed.
5.The
12C508A
was broken on the controller.
6. Computer cable of 12PIN didn’t connect into
right position.
7. Computer cable of 12PINwas broken.
8. Console was broken.
5.Replace
“12C508A”
or controller.
6.Plug the cable again on controller,
connector and console.
7.Gray and purple wires got damage,
replace the wires.
8. Replace console.
When press “START” button to start
treadmill, running belt is getting
running but window displays “LS”
error message after 8 seconds.
*Speed sensor cable was broken
(open), console can’t receive signal
for unusual speed.
1. The distance is too long between speed sensor
cable and magnet.
2. Sensor cable was broken.
3. Computer of 12PIN didn’t connect in right
position.
4. Computer cable of 12PIN was broken.
5. Console was broken.
1.Adjust the distance to 5mm between
speed sensor cable and magnet.
2.Replace sensor cable.
3.Plug the cable again on controller,
4.connector and console. Gray and
purple wires got damage, replace the
wires.
5.Replace console.
The windows display is not 1 to 18.0
km/h
1. Monitor is not calibrated.
1.Calibrate the monitor.
The speed of running doesn’t match
with console display.
1. Monitor is not calibrated.
1.Calibrate the monitor.
The windows display “Err”
1. EEPROM was broken or accessing problem. 1.Replace console and calibrate it.
After pressing “START” button, the
treadmill stop immediately.
1. Controller was broken.
1.Replace controller and calibrate it.