M965523 Rev. 1.5 (4/17)
1
2
INSTALL ESCUTCHEONS
INSTALL ROUGH PIPING
IMPORTANT NOTICE TO THE INSTALLER!
Please check with your local Code Authority for acceptable installation requirements for this
Roman Tub set with hand shower. Some local codes may require a vacuum breaker and/or
a pressure balanced mixing valve to be installed in conjunction with this product.
CAUTION
Turn off hot and cold water
supplies before beginning.
1-5/8"
(41 mm)
1-5/8"
(16 mm)
CROSS BRACE
C/L
C/L
1/2" NPT
(13 mm)
FINISHED WALL
OPTIONAL TO
FINISHED FLOOR
FINISHED
WALL
FINISHED
WALL
OFF-SET NIPPLE
PIPE
BRACE
6"
(152 mm)
COLD
HOT
1
2
2
1
C/L OF SUPPLIES (MIN).
C/L TO C/L OF
ADAPTER
C/L TO C/L OF
ADAPTER
C/L OF SUPPLIES (MAX.).
6"
(152 mm)
1/4" (6 mm) OFF-SET
5-1/2"
(140 mm)
Figure A
.
Figure B.
Figure C.
6"
(152 mm)
6-1/2"
(165 mm)
6" ±1/2"
(152 ±13 mm)
• Determine where the finished wall location will be.
This measurement is very important!
Note: The rough-in measurement from the finished wall to
the end of the off-set nipple is 1-5/8” (41mm).
See rough-in illustration below.
Figure A.
• The C/L of the supplies are 6", ±1/2".
Figure B.
• Install a cross brace between the wall studs.
• Apply thread sealant or Teflon Tape to threads of Hot and
Cold supplies connections. Assemble 1/2" (13 mm) NPT
SUPPLIES at 6" (152 mm) from center to center. Thread
ECCENTRICS
(1)
into roughed-in 1/2” SUPPLY
COUPLINGS
(2)
. Center to center dimension of
ECCENTRICS
(1)
is 6" (152 mm).
Figure C.
• Finish all wall construction.
6 "
(152mm)
1
2
• Thread ESCUTCHEONS
(1)
flush against finished wall.
Make sure ECCENTRICS
(2)
are level.