DXV Percy D35105500 Скачать руководство пользователя страница 3

- 3 -

M965527 Rev. 1.6

By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the
HOT LIMIT SAFETY STOP 

(1)

 reduces risk of accidental scalding. To set the maximum hot water

temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP 

(1)

.

• Turn CARTRIDGE STEM 

(2)

 to the OFF position (coldest setting) before making adjustment to HOT

LIMIT STOP 

(1)

. Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP 

(1)

. Pull

forward and rotate counterclockwise one number to limit hot water temperature.
Use ARROW

 (3)

 on CARTRIDGE

 (4)

 and NUMBERS 

(5)

 on HOT LIMIT STOP 

(1)

for indication.

15

131

197

531

15

13

1

1

9

7

5

3

1

 

15

1

3

1

1

9

7

5

3

1

 

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

1

5

1

5

4

4

3

3

2

2

ADJUST HOT LIMIT STOP (MUST BE DONE PRIOR TO TRIM INSTALLATION)

3

BACK TO BACK INSTALLATION

(SEE ILLUSTRATION STEP 6 FOR REFERENCE)

TEST INSTALLED FAUCET

• Remove Handle and Trim from Valve.

See step 3 for reference.

• Remove PRESSURE BALANCE UNIT 

(5)

. Rotate

PRESSURE BALANCE UNIT 

(5)

 180˚ so that the inlets

face up and the large outlet port faces down.

• Push PRESSURE BALANCE UNIT 

(5)

 in casting make

sure inlets line up with holes in bottom of casting. Top
flange should butt up against top of casting.

• Reassemble FIXATION RING 

(4)

 and CARTRIDGE 

(1)

.

• Turn VALVE "off".

• With HANDLE in "off" position, turn on water supplies

and check all connections for leaks.

• Operate HANDLE and flush water lines thoroughly.

• Check all connections for leaks.

4

5

• Remove Handle and Trim from Valve. See step 3 for reference.
• Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS

on valve, if present.

TO GAIN ACCESS TO VALVE FOR SERVICING

• Remove CARTRIDGE 

(1)

 by removing CARTRIDGE SCREWS 

(2)

. Remove three SCREWS 

(3)

 from FIXATION RING 

(4)

 and

pull out PRESSURE BALANCING 

(5)

 unit.

• Clean SEALS 

(9)

 on base of CARTRIDGE 

(1)

. Check base of PRESSURE BALANCING UNIT 

(5)

 and clean O-RINGS 

(6)

Remove CAPS

 (7)

 and check O-RINGS on inside of CAPS 

(7)

. Clean inside sealing surfaces of VALVE BODY 

(8)

.

• Re-assemble PRESSURE BALANCING UNIT 

(5)

 and CARTRIDGE 

(1)

. Tighten all screws. Turn on water supply and see

above for installing TRIM and HANDLE.

VALVE LEAKS WHEN SHUT OFF

• Remove PRESSURE BALANCE UNIT 

(5)

. Remove CAPS 

(7) 

and clean valve thoroughly.

• Examine balancing unit and check condition of O-ring on end of piston.  Piston should move back and forth. Order Repair

Part M952100-0070 if balancing unit is defective.

• Replace CAPS 

(7)

 and install PRESSURE BALANCE UNIT 

(5)

. Make sure inlets line up with two holes in bottom of casting.

Top flange should butt-up against top of casting.

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

BACK TO BACK INSTALLATION

ROTATE 180

˚

1

2

9

5

5

7

8

6

4

3

INLETS

LARGE OUTLET

6

Содержание Percy D35105500

Страница 1: ...stado de México 55540 Toll Free 01 800 8391200 www DXV mx Cylinder Handle Model D35105500 To be used with D35000500 191 Pressure Balanced Shower Valve Cross Handle Model D35105540 Phillips Screwdriver Regular Screwdriver THREADED INLETS STOPS INLETS 1 2 NPT 1 2 NPT PLUG 3 3 8 86mm FINISHED WALL BOTTOM OF SHOWER OR TUB 48 to 54 1219 to 1372mm OPTIONAL OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 72 t...

Страница 2: ...OLDER 4 with gasket onto CARTRIDGE CAP 2 Mount ESCUTCHEON SUPPORT 5 to ESCUTCHEON HOLDER 4 with four SCREWS 6 Figure 3 Push ESCUTCHEON 7 onto CARTRIDGE CAP 2 tight against finished wall Align mounting holes and install the two MOUNTING SCREWS 8 and tighten Figure 3 7 2 8 Figure 1 VALVE CARTRIDGE 1 2 3 GASKET MOUNTING HOLES Figure 2 4 5 6 2 VALVE MOUNTING HOLES INSTALL HANDLE Push DIAL PLATE 1 onto...

Страница 3: ...inst top of casting Reassemble FIXATION RING 4 and CARTRIDGE 1 Turn VALVE off With HANDLE in off position turn on water supplies and check all connections for leaks Operate HANDLE and flush water lines thoroughly Check all connections for leaks 4 5 Remove Handle and Trim from Valve See step 3 for reference Shut off water supply by either closing off main water supply or closing off the hot and col...

Страница 4: ...L MODEL NUMBERS D35105540 D35105500 Cylinder Handle Cross Handle M964654 0070A TRIM PLATE HOLDER M964656 YYY0A TRIM PLATE WITH SCREWS HOT COLD OFF M964749 YYY0A HANDLE BASE M964697 YYY0A CROSS HANDLE KIT M964610 YYY0A CYLINDER HANDLE KIT H961229 XXX TRIM RING H960685 XXX ESCUTCHEON SCREWS A3195 191 EXTENSION KIT CARTRIDGE A3196 191 EXTENSION KIT DIVERTER ...

Отзывы: