- 2 -
2
2
4
4
8
9
12
11
13
10
14
6
7
ESCUTCHEON
O-RING
1
3
Figure A
M965531 Rev. 1.7 (1/18)
1
2
3
INSTALL HANDLE
• Remove PLASTER GUARDS and unthread ROUGH-IN NIPPLE
(1)
.
• Inspect that SPOUT NIPPLE O-RINGS
(2 & 3)
are seated in the grooves of SPOUT NIPPLE
(4)
.
• Thread SPOUT NIPPLE
(4)
into VALVE BODY
(5)
. Tighten SPOUT NIPPLE
(4)
to VALVE BODY
(5)
.
• Thread ESCUTCHEON MOUNT
(6)
onto SPOUT NIPPLE
(4)
until it engages the O-RING
(2)
.
• Push the SPOUT ESCUTCHEON
(8)
onto ESCUTCHEON MOUNT
(6)
until it seats against the internal stop.
Tighten SET SCREW
(9)
with HEX WRENCH
(12)
supplied.
• Thread ESCUTCHEON
(8)
flush against finished wall. SET SCREWS
(9 & 11)
should point down toward the floor after tightening.
• Make sure ESCUTCHEON O-RING
(7)
is in place. Push ESCUTCHEON
(14)
onto SPOUT ESCUTCHEON
(8)
and flush against finished wall.
• Push SPOUT
(10)
with SPOUT O-RINGS
(13)
into ESCUTCHEON
(8)
until seated against stop. Align SPOUT
(10)
and tighten SPOUT SET SCREW
(11)
with HEX WRENCH
(12)
supplied.
• Determine where the finished wall location will be.
This measurement
is very important!
Note:
The rough-in measurement from the finished
wall is; 1-9/16" (40 mm) minimum and 2-7/16" (62 mm) maximum.
This is a 7/8" (22 mm) tolerance. See rough-in illustration.
• Secure WALL BRACKET
(1)
to cross brace of wall structure
at required height using six wood screws.
• Mount VALVE BODY
(1)
to WALL BRACKET
(2)
as shown. Level and tighten
SET SCREWS
(3)
to secure VALVE BODY
(1)
to WALL BRACKET
(2)
.
• Connect HOT water supply to LEFT INLET UNION
(4)
and COLD water supply
to RIGHT INLET UNION
(5)
. Pipe connections are 1/2” NPT. Use sealant or
Teflon tape on pipe connections.
Do not solder directly to valve body.
• With valves closed open supply lines and check for leaks. Remove
PLASTER GUARDS
(6)
and open both valves and check for leaks.
• Close both valves and turn off water supplies. Replace
PLASTER GUARDS
(6)
and finish wall construction.
INSTALL WALL BRACKET
INSTALL VALVE BODY
WOOD SCREWS
CROSS BRACE
WALL STUDS
1
16"
(406 mm)
HOT
COLD
6
6
5
4
3
2
1