background image

- 2 -

12 

11

13

10 

14 

ESCUTCHEON

O-RING

 

Figure A

M965531 Rev. 1.7 (1/18)

1

2

3

INSTALL HANDLE

• Remove PLASTER GUARDS and unthread ROUGH-IN NIPPLE 

(1)

.

• Inspect that SPOUT NIPPLE O-RINGS 

(2 & 3) 

are seated in the grooves of SPOUT NIPPLE

 (4)

.

• Thread SPOUT NIPPLE

 (4) 

into VALVE BODY

 (5)

. Tighten SPOUT NIPPLE 

(4) 

to VALVE BODY 

(5)

.

• Thread ESCUTCHEON MOUNT

 (6)

 onto SPOUT NIPPLE

 (4) 

until it engages the O-RING 

(2)

.

•  Push the SPOUT ESCUTCHEON

 (8) 

onto ESCUTCHEON MOUNT

 (6) 

until it seats against the internal stop.  

Tighten SET SCREW

 (9)

 with HEX WRENCH

 (12) 

supplied.

•  Thread ESCUTCHEON

 (8)

 flush against finished wall. SET SCREWS 

(9 & 11) 

 

should point down toward the floor after tightening.

•  Make sure ESCUTCHEON O-RING 

(7)

 is in place. Push ESCUTCHEON

 (14) 

 

onto SPOUT ESCUTCHEON

 (8) 

and flush against finished wall.

•  Push SPOUT 

(10) 

with SPOUT O-RINGS

 (13) 

into ESCUTCHEON

 (8)

  

until seated against stop. Align SPOUT

 (10) 

 

and tighten SPOUT SET SCREW 

(11)

  

with HEX WRENCH

 (12) 

supplied.

      

•  Determine where the finished wall location will be. 

This measurement 

is very important!

  

Note:

 The rough-in measurement from the finished 

wall is; 1-9/16" (40 mm) minimum and 2-7/16" (62 mm) maximum.  
This is a 7/8" (22 mm) tolerance. See rough-in illustration.   

•  Secure WALL BRACKET

 (1)

 to cross brace of wall structure 

at required height using six wood screws.

•  Mount VALVE BODY

 (1)

 to WALL BRACKET

 (2)

 as shown. Level and tighten 

SET SCREWS 

(3)

 to secure VALVE BODY 

(1)

 to WALL BRACKET

 (2)

.

•  Connect HOT water supply to LEFT INLET UNION

 (4) 

and COLD water supply 

to RIGHT INLET UNION

 (5)

. Pipe connections are 1/2” NPT. Use sealant or 

Teflon tape on pipe connections.

 Do not solder directly to valve body.

•  With valves closed open supply lines and check for leaks. Remove  

PLASTER GUARDS 

(6)

 and open both valves and check for leaks.

•  Close both valves and turn off water supplies. Replace  

PLASTER GUARDS 

(6)

 and finish wall construction.

INSTALL WALL BRACKET

INSTALL VALVE BODY

WOOD SCREWS

CROSS BRACE

WALL STUDS

16"

(406 mm)

HOT

COLD

Содержание Percy D35105470

Страница 1: ...el Locks Teflon Tape 2 3 8 D 60 mm TYP 7 8 22 mm 3 77 mm 8 203 mm 11 279 mm CROSS HANDLE LEVER HANDLE TRI SPOKE HANDLE 2 1 2 63 mm 1 26mm 1 5 8 to 2 1 2 41 mm to 62 mm FINISHED WALL FINISHED WALL 8 3 8 213 mm 3 3 16 80 mm 7 5 8 194 mm 1 2 NPT UNION INLETS In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United State...

Страница 2: ...OUT 10 and tighten SPOUT SET SCREW 11 with HEX WRENCH 12 supplied Determine where the finished wall location will be This measurement is very important Note The rough in measurement from the finished wall is 1 9 16 40 mm minimum and 2 7 16 62 mm maximum This is a 7 8 22 mm tolerance See rough in illustration Secure WALL BRACKET 1 to cross brace of wall structure at required height using six wood s...

Страница 3: ...ew Slide BARREL SLEEVE WASHER 1 onto VALVE STEM 2 until WASHER 1 is on the smooth section of the VALVE STEM 2 Thread BARREL SLEEVE 3 onto VALVE BODY 4 and tighten Make sure ESCUTCHEON O RING 5 is in place Slide ESCUTCHEON 6 onto BARREL SLEEVE 3 flush against finished wall Align HANDLE as shown or as desired and install HANDLE ASSEMBLY 7 7a 7b onto VALVE STEM 2 Thread HANDLE BASE 8 onto BARREL SLEE...

Страница 4: ...HROME 100 BRUSHED NICKEL 144 H960853 191 ADAPTER H960854 191 ADAPTER RECEIVER M964641 YYY0A SPOUT ESCUTCHEON KIT M964625 YYY0A HANDLE ESCUTCHEON KIT M964643 YYY0A SPOUT BODY M964623 YYY0A LEVER HANDLE M970431 YYY0A CROSS HANDLE H960202 XXX EXTENSION M964617 0070A SET SCREW M964636 0070A AERATOR KIT M964644 YYY0A SPOUT KIT M964646 0070A SPOUT 0 RINGS M964618 0070A SET SCREW KIT H960740 191 EXTENSIO...

Отзывы: