background image

- 8 -

M965474 Rev. 1.5 (3/17)

Fig.

 

J.

Fig.

 

K.

INSTALL

CAM CAP

CAM

INSTALL CAM

Unlocked Mode

Locked Mode

(Vandal Proof)

DRAIN

Fig.

 

G.

LOOP TOWARD

REAR OF SINK

LOOP TOWARD

FRONT OF SINK

180˚

DRAIN

Fig.

 

H.

LOCKED MODE:

•  Look at the Plastic Loop at the bottom of the Stopper and notice 

that the Loop is on one side of the Stopper. 

Fig. G.

•  To install the stopper in 

“Locked”

 mode, insert the Stopper into 

the Drain so that the Plastic Loop is facing toward the 

rear

 of the 

Sink. Rotate Stopper slightly if necessary so that the Stopper slides 
all the way down. 

Fig. G.

•  Re-install the Cam into the Drain, rotating the Cam if necessary 

to make sure it is fully inserted. 

Fig. J.

•  Re-install the Cam Cap, making sure the guide teeth are facing 

outward. If the Cam Cap does not “snap” into place, then rotate 
the Cam to make sure it is fully inserted. 

Fig. K.

•  Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in 

Troubling Shooting Guide to complete installation. Stopper will be 
in 

“Locked”

 mode and not be removable.

UNLOCKED MODE:

•  Look at the Plastic Loop at the bottom of the Stopper and notice 

that the Loop is on one side of the Stopper.

 Fig. H.

•  To install the stopper in 

“Unlocked” 

mode, insert the Stopper into 

the Drain so that the Plastic Loop is facing toward the 

front

 of the 

Sink. Rotate Stopper slightly if necessary so that the Stopper slides 
all the way down. 

Fig. H.

•  Re-install the Cam into the Drain, rotating the Cam if necessary 

to make sure it is fully inserted.

 Fig. J.

•  Re-install the Cam Cap, making sure the guide teeth are facing 

outward. If the Cam Cap does not “snap” into place, then rotate 
the Cam to make sure it is fully inserted. 

Fig. K.

•  Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in 

“Troublingshooting Guide” to complete installation. Stopper will be 
in 

“Unlocked”

 mode and removable.

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed)

or “Unlock” Mode (Stopper is removable).

Содержание Keefe D35104100

Страница 1: ...5474 Rev 1 5 3 17 Monoblock Vessel Model D35104150 Monoblock Model D35104100 Keefe Single Lever Faucet Flat Blade Screwdriver Plumber s Putty or Caulking Adjustable Wrench Tubing Cutter Channel Locks ROUGHING IN DIMENSIONS NOTE Mounting holes are 1 3 8 D In the United States DXV One Centennial Avenue Piscataway New Jersey 08855 Attention Director of Customer Care For residents of the United States...

Страница 2: ... WASHER 4 and LOCKNUT 6 onto faucet SHANK 3 Before final tightening faucet should be seated flush on mounting surface Adjust faucet so that it is centered and covers mounting hole Tighten LOCKNUT 6 using a 15mm or adjustable wrench Do not over tighten Installation is the same for VESSEL FAUCET 8 INSTALL FAUCET LAVATORY AND VESSEL FAUCETS CAUTION Turn off hot and cold water supplies before beginnin...

Страница 3: ...GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 6 must face towards the rear of the SINK Fig B From under side of SINK install RUBBER CONE WASHER 3 PLASTIC WASHER 2 and LOCKNUT 1 onto DRAINBODY 4 Note The CABLE ATTACHMENT POINT 5 must face towards the rear of the SINK Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET ...

Страница 4: ... refer to the troubleshooting section of these instructions Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 10 mm compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 24 610 mm long from faucet base Note If additional supply length is required installer must purchase additional part...

Страница 5: ...perate POP UP KNOB 3 and fill lavatory with water Check that DRAIN STOPPER 3 makes a good seal and retains water in sink If DRAIN STOPPER 3 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 3 down and check all drain connections and P trap for leaks Tighten if necessary TEST INSTALLED FITTING 4 P TRAP WASTE OUTLET 2 2 OFF ON 3 1 HOT COLD ...

Страница 6: ...OVIDED 2 to remove cartridge Figure B Push the inlet hoses up to remove the manifold from faucet Figure C Use hex key to remove NUT 3 Figure C Replace FLOW REGULATOR 4 with new one Figure C Follow the above steps in reverse to install faucet components 12 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH S...

Страница 7: ... Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F If sink does not hold water even though Stopper is in the down position Follow CABLE ADJUSTMENT PROC...

Страница 8: ...USTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be in Locked mode and not be removable UNLOCKED MODE Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink Rotate Sto...

Страница 9: ...50 Lavatory Faucet D35104100 Keefe Single Lever Lavatory and Vessel Faucets M964500 YYY0A HANDLE KIT M964501 0070A CARTRIDGE KIT M964506 0070A SEAL M964502 0070A FLOW RESTRICTOR M952430 0070A SPEED CONNECT ASSEMBLY M964504 YYY0A LIFT ROD ASSEMBLY M964507 0070A MOUNTING KIT 874214 XXX DRAIN ASSEMBLY M964818 0070A SEAL KIT M921935 0070A ADAPTOR ...