DXI MicroComm ICE-400 Series Скачать руководство пользователя страница 4

ICE-400 Series Intercom Stations 

Page 4 

 

Document IM-ICE-400-1.1  

speaker and LED are connected using two terminal MTA connectors so that the customer can connect a 4-terminal 
MTA-100 to the switch input terminals. 

 

MTA Pin 

Signal 

1 LED 

2 LED 

Switch 2 - 

Switch 2 + 

Switch 1 - 

Switch 1 + 

7 Speaker 

8 Speaker 

 

4. 

Two Sided Door Primary/Secondary Pair 

The two sided Door Primary/Secondary paired stations are meant to provide an intercom on both sides of a door 
at the same time but require only one audio channel. The two stations are configured as a single intercom station 
with one call switch. This is achieved by paralleling the speaker and switch of the secondary station to the speaker 
and switch of the primary station. The following diagram shows the necessary connections. The connections can 
be made using a 4-wire cable with a 4-pin MTA connectors at one end. The 4 pins of the 4-pin MTA connector are 
connected to the header CN6 (CN7) labeled Slave B of the primary station and are connected to the secondary 
speaker and switch pig tail wires with Marr connectors. Note that the switch and speaker connections are not 
polarity sensitive so that the connector can be reversed. 

The two intercom stations are assigned custom numbers, where they are both 2-gang stations the primary 
intercom station is ICE-420-CUS-110 while the secondary station is ICE-320-CUS-101. 

SPK

SW

SW

SPK

S

lave

 B

SPK+

SPK

-

SWB+

SWB-

SWA+

SWA-

LED+

LED-

S

la

ve A

SPK

SW

SW

SPK

LI

NE

+

-

-

+

PCB

06741-04

F

a

cep

la

te

Pin 1

Pin 1

Pin 1

Pin 1

SW B

SW B

To SAB 400(401) or SCC 400(401)

Maintain Polarity and Leave Shield 

Unconnected at this end

Secondary ICE-320-CUS-101

Primary ICE-420-CUS-110

Marr

Conector

Marr

Conector

Marr

Conector

Marr

Conector

4-wire Cable Terminated

with MTA-4 Connector

Yellow

Yellow

Green

Black

 

Two Sided Door Primary/Secondary Pair with Two Call Switches acting as one call switch 

 

Содержание MicroComm ICE-400 Series

Страница 1: ...s These include i 0 1 or 2 switches These switches are mounted on the faceplate and internally terminated They can be used for call request program music selection or other functions The terminations allow the system to detect open or short line faults The switch information is multiplexed with the audio signals over a single pair of wires ii The LED stations ICE 421 and ICE 431 are used with SAB ...

Страница 2: ...simplified diagram of the back view of an ICE 420 with one faceplate mounted switch is shown below The headers CN2 CN3 and CN8 CN9 are always present Connector CN2 CN3 is used to connect the printed circuit board to the faceplate components Microphone Speaker Switch B Switch A and LED Connector CN8 CN9 is used to connect the field wiring audio lines via of a 4 pin MTA 100 04 connector SPK SW SW SP...

Страница 3: ...air should connect to pins 1 and 2 on a female 4 pin AMP MTA 100 series connector that plugs onto the header CN8 CN9 labeled LINE on the intercom station printed circuit board To make these connections you should use an AMP Handle Assy 58074 1 tool with a 58246 1 head The cable should be cut to length and the shield and outer jacket should be trimmed back about 1 2 inch Ensure that the shield is n...

Страница 4: ...h a 4 pin MTA connectors at one end The 4 pins of the 4 pin MTA connector are connected to the header CN6 CN7 labeled Slave B of the primary station and are connected to the secondary speaker and switch pig tail wires with Marr connectors Note that the switch and speaker connections are not polarity sensitive so that the connector can be reversed The two intercom stations are assigned custom numbe...

Страница 5: ...0 CUS 110 Marr Conector Marr Conector Marr Conector Marr Conector Black Green Yellow Yellow 4 wire Cable Terminated with MTA 4 Connector Two Sided Door Primary Secondary Pair with Two Separate Call Switches 5 Mounting ICM The ICE 420 and ICE 421 Intercom Stations are designed to mount in a standard 2 gang electrical box with the faceplate connected to the box by four 6 32 mounting screws The box m...

Страница 6: ...om Stations Page 6 Document IM ICE 400 1 1 4 Mounting Holes 0 188 3 16 6 38 3 63 4 50 3 28 Switch B LED Switch A Minimum Opening 5 44 W x 2 88 H x 1 75 D 3 Gang Mounting Hole Details for 2 gang and 3 gang Intercom Stations ...

Отзывы: