background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 1:

 

RLS-2 Used with  

Two RBS-1 Reversible Beverage Systems

 

 
  

Notes: 

 

Uses single coax run from each

 DXE-RBS-1FP

 

 

Uses voltage on the feedline to switch the 

DXE-RLS-2

 and the 

DXE-RBS-1FP

 

 

DXE-RLS-2

 switches when +12 Vdc is applied to feedline, 

DXE-RBS-1FP

 switches when  −12 

Vdc is applied giving port selection per table below 

 

Voltage Applied to 

Feedline 

Selected Port 

0 Vdc 

Beverage A, Away 

-12 Vdc 

Beverage A, Toward 

+12 Vdc 

Beverage B, Away 

12 Vac 

Beverage B, Toward 

 

 

The 

DXE-FVC-1

 applies the voltages to the feedline and can be controlled using BCD logic 

        with the 

CC-8A

 or a switch closure to ground arrangement 

Содержание RLS-2

Страница 1: ...na Switch RLS 2 DXE RLS 2 INS Revision 3a DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEnginee...

Страница 2: ...receive antennas Operation The RLS 2 is in effect a SPDT Single Pole Double Throw RF switch that has one input port and two output ports With no control voltage the NC normally closed ANT 1 port is co...

Страница 3: ...es when 12 Vdc is applied to feedline DXE RBS 1FP switches when 12 Vdc is applied giving port selection per table below Voltage Applied to Feedline Selected Port 0 Vdc Beverage A Away 12 Vdc Beverage...

Страница 4: ...Vdc Ant Array 1 Segment A 12 Vdc Ant Array 1 Segment B 12 Vdc Ant Array 2 Segment C 12 Vac Ant Array 2 Segment D The FVC 1 applies the voltages to the feedline and can be controlled using BCD logic wi...

Страница 5: ...r installation Optional Items DXE CC 8A Control Console 8 Position The CC 8A Control Console is a flexible 8 position controller used to control the DX Engineering RR8 series antenna switches the RFS...

Страница 6: ...two antenna ports The standard configuration of the RBSA 1P has one port terminated termination included so both antennas share a common feedline Applying negative 10 to 18 Vdc to the feedline switch...

Страница 7: ...these connectors DXE CPT 659 Coax Cable Stripper for CATV F 6 RG 6 and RG 59 coax Prepares CATV F 6 RG 6 and RG 59 coax cable for the installation of an F type connector One step cutting motion Precis...

Страница 8: ...warranted to be free from defects in material and workmanship for a period of one 1 year from date of shipment DX Engineering s sole obligation under these warranties shall be to issue credit repair...

Отзывы: