DX Engineering DXE-SMBA-2 Скачать руководство пользователя страница 10

- 9  - 

Using the Auto-Tuner 

 
When using the tuner, refer to the MFJ-927 manual for details. If you try tuning and it seems that 
the tuner will not tune up as it should, try 'band switching'. Band switching for this means going up 
or down one band, re-tune, and then go back to the desired band and re-tune again.  
 
Grounding at the unit is important. Ensure you have a good ground at the tuning unit. 
 
 

When installing the unit, the four ground spikes

 must

 be pushed into the soil to provide a 

good ground.  

 

If your soil is not a good ground (sandy, real hard dirt, etc.), adding a customer supplied 
ground rod which is connected to the unit at one of the radial connection points will help 
provide a good ground. 

 
 

 

Please

 

read and understand the instruction manual that comes with the 

MFJ-927 

Remote 

IntelliTuner™ Automatic Antenna Tuner.  
 
There is information included in that manual that is critical to proper operation of both the 
IntelliTuner™ Automatic Antenna Tuner and the Bias "T".  
 
There is also troubleshooting information and tuner reset information that may be very 
helpful.

 

 

 

Removing the Tuner 

 
To access the inside of 
the MFJ-927 tuner it 
will have to removed 
from the shelf. Remove 
your coaxial cable from 
the right angle UHF 
adapter and remove the 
wire going from the 
tuner's red post to the 
MatchBoxx. Remove 
the four hex head nuts 
as shown below. The 
other hardware shown 
does not have to be 
removed.  
 
 

Содержание DXE-SMBA-2

Страница 1: ...na System DXE SMBA 2 Patent Pending DXE SMBA 2 INS Revision 1 DX Engineering 2010 P O Box 1491 Akron OH 44309 1491 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E...

Страница 2: ...the air and operating right under their noses This system can be used if your shack is on the main floor basement or any other location as long as you can run any size coax to the RTU located outside...

Страница 3: ...ool of 14 gage stranded copper wire with relaxed black PVC insulation 20 Ring Terminals for Radial Wires Typical radial system is twenty radials each 25 feet long DXE STPL 100P Metal Lawn Staples 100...

Страница 4: ...mum 20 radials each 25 feet long should be used with this antenna Using extra radials may help overcome unknown poor soil conditions improve bandwidth and ensure the best performance possible from the...

Страница 5: ...round spikes as shown below DXE 81343 Anti Seize should be used on all stainless steel hardware to prevent galling Bottom View Mount serpentine insulator to the shelf using one hex bolt star washer fl...

Страница 6: ...l wires on the corner nearest the insulator Radial Wire Pattern Bias T Connections Refer to the MFJ manual for details on the Bias T The Bias T supplies the DC power required in the remote tuner using...

Страница 7: ...n 40 through 10 meters Weave the soldered terminal on the wire antenna element through the serpentine insulator installed on the SMBA 2 shelf and connect it to the MatchBoxx wing nut titled ANT as sho...

Страница 8: ...pped out area to assist in a smooth wire transition point Antenna Element Wire Attaching Rope to the End Insulators DX Engineering Double braided Polyester Rope STI DBR should be secured to the end in...

Страница 9: ...na element are Connect the antenna element from the SMBA 2 to a roof eve then to a tree Connect the antenna element from the SMBA 2 to a tree Connect the antenna element from the SMBA 2 to a tree then...

Страница 10: ...h is connected to the unit at one of the radial connection points will help provide a good ground Please read and understand the instruction manual that comes with the MFJ 927 Remote IntelliTuner Auto...

Страница 11: ...raid Dacron Polyester Rope 100 ft Roll Synthetic Textile Industries Double braided Dacron Polyester ropes are not weakened by decay or mildew and provide excellent resistance to abrasion The color sea...

Страница 12: ...rendered defective by reason of improper installation damaged from severe weather including floods or abnormal environmental conditions such as prolonged exposure to corrosives or power surges or by t...

Отзывы: