background image

DXE-RR2X8 and DXE-MX2X8 Installation

 

 

1.   Secure the 

DXE-RR2X8B

 switching unit using the included 

DXE-SSVC-2P

 stainless steel V-

Saddle Clamp.  

 
 

Mount the 

DXE-MX2X8

 close to the 

DXE-RR2X8B

 

to keep the interface cable lengths between these units  
to a minimum using the included 

DXE-SSVC-2P

 

stainless steel V-Clamp.  

 
 

The two pictures on this page show just two versions 
of mounting the units. Your set up may vary. 

 
 

The connectors must face downward to avoid 
moisture.  

 
 

Use Never-Seez

®

, Anti-Seize or Jet Lube SS-30 on 

all stainless steel hardware to prevent galling. 

 
2.   Fasten all cables to the mounting mast or tower to 

relieve strain, and gently droop the cables to form a 
drip loop (do not use tight bends with coaxial cable). 
Install both of the units with the connectors facing 
down and use gradual bends or loops in heavy wires. 
If the system is mounted to a wooden pole or building, 
a wide copper flashing or heavy wire or strap should 
be connected from the mounting bracket to a good 
ground. 

 

Note:  

Do not seal the connectors! The connectors are 
recessed inside a drip edge that prevents water 
from getting into connectors. The cover-to-
connector plate junction is not sealed so the unit 
can "breathe” and eliminate condensation.

 

Содержание DXE-RRMX2X8

Страница 1: ...io Switch System DXE RRMX2X8 DXE RRMX2X8 INS Revision 0a DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mai...

Страница 2: ...erformance and are moisture resistant The DXE RRMX2X8 system can be used to simultaneously select multiple output ports as well as conventional one of eight antenna switching This allows the DXE RR2X8...

Страница 3: ...hielded control cable that has 10 conductors and works very well for running control signals for the DXE RR2X8 and DXE MX2X8 Note Do not seal the connectors The connectors are recessed inside a drip e...

Страница 4: ...erator A selects the same port that operator B has selected operator A will not hear anything no port selected Care is then needed so operator A does not transmit into an open The two signals MIL and...

Страница 5: ...ut instead of being firmly gripped The green connectors are in two parts and the top part plug can be removed by pulling it straight off This will allow easier wire replacement or servicing as needed...

Страница 6: ...roubleshooting Use the chart below to record which color wire is connected to each terminal connection of each cable DXE RR2X8 Master Connector Control Wire Color Master Connector DXE MX2X8 M Master S...

Страница 7: ...here are four additional wires used One for Ground one for 12 VDC one for MIL and one for SIL more on MIL and SIL later The ten pin green connector located on the DXE MX2X8 is used to for two BCD cont...

Страница 8: ...ted GND 12 VDC MIL SIL GND 12 VDC is the line that needs station power usually 13 8 VDC nominal connected to it This line supplies the voltage needed to operate the relays The two GND Ground wires sho...

Страница 9: ...all stainless steel hardware to prevent galling 2 Fasten all cables to the mounting mast or tower to relieve strain and gently droop the cables to form a drip loop do not use tight bends with coaxial...

Страница 10: ...here is no antenna selected since there will be no audio from any signals coming into Radio B A very simplified schematic is shown Master Radio A and Slave Radio B can never use the same output port a...

Страница 11: ...60 MHz Ports Not Selected Are Grounded Loss 0 3 dBm below at 52 MHz Impedance 50 ohms Manual Updates Every effort is made to supply the latest manual revision with each product Occasionally a manual...

Страница 12: ...allation damaged from severe weather including floods or abnormal environmental conditions such as prolonged exposure to corrosives or power surges or by the performance of repairs or alterations outs...

Отзывы: