Page 5
limiting, then all signals on all frequencies will drop by the same 20 dB. That’s probably not what the operator
wants.
For high RF environmental problems, like the nearby strong AM station, inline RF filters should be used to
remove AM band energy from amateur antennas.
Additional Items Suggested but not Supplied
DX Engineering RG-8X 50 Ω BNC Coaxial Cable Assemblies
DXE-1155
Coaxial Cable Adapter - BNC Male to F-Type Female
DXE-RLP-75FF
- Lightning Protector, Receive 75Ω, DC Pass, F Connectors
See the
Optional Items
page near the end of this manual for complete details about these
items as well as other suggested options.
Installation
The
DXE-RG-5000HD
Receiver Guard is intended to be installed indoors, at the radio. The following
pages show various setups using the Receiver Guard. There are many more combinations possible
beyond these basic diagrams.
Figure 1
-
Home or Field Day protection
The
DXE-RG-5000HD
Receiver Guard is installed into the
“receiver loop” between the RX OUT and RX IN
connectors. On the ICOM IC-7600, press and hold the ANT
selector until 1/R is displayed on the screen as the selected
antenna. This will bring the
DXE-RG-5000HD
into the
receive loop. By doing this, you will prevent front-end
blowout from nearby transmitters received on the transmit
antenna being used by the IC-7600. Consult your transceiver
manual regarding the use of RX OUT and RX IN
connections.
Note there are optional items used all of the diagrams shown in this manual.