- 4 -
of the optimal monoband and multi-band frequency coverage of the Eight Circle Array in
sections entitled
Array Performance
,
Site Selection
and
Sizing the Array
.
2.
Are you ready to build your system? Proceed!
The
DXE-RCA8C-SYS-4S Receive Eight Circle Array Packages
includes:
DXE-RCA8C-1
Receive Eight Circle Array Controller
DXE-CC-8A
Special eight position Receive Eight Circle Control Console
modified to
p12 Vdc for powering the active antennas.
DXE-SSVC-2P
Stainless Steel V-Clamp for mounting the
RCA8C-1
Receive Eight Circle
Array Controller to a mounting post between 1" and 2" OD
Two
DXE-ARAV4-4P
(Eight total Active Matching units with Internal Disconnect Relays,
Aluminum Vertical Elements, Insulated Mounting System and Stainless Steel V-Clamps to
be used with customer supplied ground rods for mounting
DXE-RG6UFQ-1000
(Two) 1000 Foot Rolls, Quad Shield Coaxial Cable, 75Ω, RG6
Flooded Cable
DXE-CPT-659
Coaxial Cable Prep Tool for RG6, 75Ω Coaxial Cable, w/extra blade
DXE-SNS-CT1
F-Connector Compression Tool for 75Ω coaxial cable connectors
DXE-EX6XL-25
Package of 25 F Connectors for quad shield 75Ω RG6 coaxial cable
Additional Parts Required, Not Supplied with the DXE-RCA8C-SYS-4S
One additional DXE-RG6UFQ-1000
75Ω quad shield Coaxial Cable that may be required
for the main feedline from the station to the array
Five-Conductor Power and Control Cable.
The modified
DXE-CC-8A
Control Console
interfaces to the
DXE-RCA8C-1
Eight Circle Array Controller through a 5-wire cable to
select one of eight directions and to power the eight active elements. Economically priced
DXE-CW9S
is a 9-conductor control wire which may be used allowing the user to use the
spare wires to double up on power and return lines for current carrying capability.
Eight Circle Layout
The optimized array for single band performance has vertical elements
arranged in a circle with a
radius
of about 175 feet for 160 meters, or 84
feet for 80 meters, or 44 feet for 40 meters. A two-band array for 80 and
160 meters should also have a radius of about 84 feet. See the
Theory of
Operation
sections for exact dimensions, options for wider frequency
coverage and guidance in choosing the best orientation.
The default direction of the array with no voltage (BCD 000) places
elements 1 and 6 in front and elements 2 and 5 at the rear, with pairs of
lines through two opposite vertical element pairs (tangents) that point toward the receiving
directions.