Страница 2: ...10 Vertical Element Feedlines 11 Typical DXE RCA8C SYS 4S Receive Eight Circle Configuration 12 Delay Line 13 Optimizing the Array 13 Theory of Operation of the Receive Eight Circle Array 14 System D...

Страница 3: ...tter signal to noise ratio Reduced susceptibility to high angle signals compared to phased Beverage antennas as well as superior performance over EWE Flag Pennant K9AY antennas Switching console selec...

Страница 4: ...coaxial cable Additional Parts Required Not Supplied with the DXE RCA8C SYS 4S One additional DXE RG6UFQ 1000 75 quad shield Coaxial Cable that may be required for the main feedline from the station...

Страница 5: ...troller eight DXE AVA2 Active Matching Units for your vertical elements and one Delay Cable with F Connectors installed These units interconnect and work together using factory default settings to con...

Страница 6: ...ller unit should be mounted as shown in Figure 3 with cover upward and the control and coaxial cable connections downward to prevent water from entering the box The stainless steel base of the Receive...

Страница 7: ...connections are labeled G A B C D The terminals use the same connection letters and are connected G to G A to A B to B C to C and D to D On the RCA8C 1 the green connector is a two part connector as s...

Страница 8: ...ol Line Lengths Minimum Copper Wire Gage AWG Length 24 1 000 feet 22 1 500 feet 20 2 000 feet Active antenna circuitry needs a good voltage supply to operate properly When supplying power to an active...

Страница 9: ...ing antennas 1 10 wavelength of the lowest transmitting frequency This is possible provided the active units are powered off at least 5 ms before transmitting An optional sequencer such as the DXE TVS...

Страница 10: ...s than 5 8 OD A good ground system improves the array performance and enhances lightning survivability It is important that the ground system is identical for each active antenna in the array You can...

Страница 11: ...use 75 feedline to the operating position from the DXE RCA8C 1 unit Do not use amplifiers combiners filters or splitters that are not optimized for 75 systems All element feedlines must be 75 and can...

Страница 12: ...en the chassis mounting nut allowing the connector body to rotate and fracture the mounting tabs on either installation or removal of the connector F connectors require modest torque typically 6 12 in...

Страница 13: ...Figure 8 Coaxial Cables are shown in various colors for clarity Shown with optional DXE RPA 2 Receive Pre Amplifier DXE RFCC Receive Feedline Current Choke and optional DXE CW9S Control Cable Power co...

Страница 14: ...na and set the receiver to the narrowest selectivity you expect to use Receiver noise power is directly proportional to receiver bandwidth going from 2 5 kHz selectivity to 250 Hz selectivity reduces...

Страница 15: ...s a clean stable pattern with high directivity over wide bandwidth W8JI initially developed and used this array in the 1980 s This array started appearing in the 1990 s at larger more advanced low ban...

Страница 16: ...roadband active elements this array has unbeatable performance across a single band The Eight Circle Array upper frequency limit for a clean unidirectional pattern is slightly above where the array is...

Страница 17: ...rimary benefit Antenna gain is a secondary advantage As frequency increases the fixed array size becomes electrically larger in terms of wavelength The increased electrical spacing produces higher sen...

Страница 18: ...uctors regardless of element design for a given style of element The effect on pattern depends almost entirely on how much surrounding objects absorb and re radiate signals if the undesired structure...

Страница 19: ...mity to Transmitting Antennas Eight DXE ARAV4 Receive Antenna Active Vertical active elements and your transmitting antenna need only minimal physical separation to maintain safe power levels when the...

Страница 20: ...best Receiving Directivity Factor RDF which is a figure that compares the forward lobe gain to the average gain of the antenna array in all directions including azimuth and elevation More information...

Страница 21: ...lowable side lobe levels as represented closely to the pattern 35 wavelength radius shown in Figure 9 For example an array built to cover 160 80 and 40 meters has a highest frequency of 7 3 MHz and a...

Страница 22: ...atterns in Figure 10 were generated using EZNEC and show the effects on the patterns when varying the radius of the array These patterns are not to be viewed as pointing in a default or particular dir...

Страница 23: ...he VF of the coaxial cable you are using you must directly measure the electrical length of the coaxial cable you have with an analyzer or obtain cable with a known VF Table 3 shows delay line length...

Страница 24: ...imensions rather than operating frequency which allows for the use of a single delay line for optimum directivity over a very wide frequency range This results in phase being correct for a rearward nu...

Страница 25: ...e Array is sized by multiplying the free space wavelength at 1 832 MHz of 537 feet wavelength times the optimum pattern circle radius of 0 327 wavelength which yields an optimal circle radius of 175 6...

Страница 26: ...2 26 66 13 172 8 345 6 319 3 0 604 3 500 70 29 35 14 91 8 183 7 169 7 0 604 3 650 67 40 33 70 88 1 176 1 162 7 0 604 3 800 80M only or 160 80M 64 74 32 37 84 58 169 2 156 3 0 604 7 200 40M only 34 17...

Страница 27: ...pulled inward C Shorted Open conductors due to water Check feedlines and control cable D Zapped by lightning pulse or RF overload Make sure units are at least 1 2 wavelength on the lowest frequency a...

Страница 28: ...Active antennas and any transmit antennas If that distance is less and high power is used then the Time Variable Sequence Unit TVSU must be used to interrupt power to the AVA2 units 2 Damaged Receive...

Страница 29: ...s disconnected from the Receive Eight Circle System relay unit If measured voltages are not between 10 to 18 Vdc on the selected line a resistive short or open circuit problem exists in the control li...

Страница 30: ...of that antenna may not be receiving power Retest for DC power at the antenna end of that feedline If 10 to 18 Vdc is found then the Active unit may need to be serviced or replaced New AVA2 units are...