Technical Support 

 
If you have questions about this product, or if you experience difficulties during the installation, 
contact DX Engineering at (330) 572-3200.  You can also e-mail us at: 
 

[email protected]

 

 

For best service, please take a few minutes to review this manual before you call. 

 
This unit is RoHS (Reduction of Hazardous Substances) compliant. The components, 
including the solder used are all lead free. If you decide to do any modifications or internal 
repairs, you should use only lead free solder and lead free soldering tools. Lead free solder 
melts approximately 100 degrees higher than the old leaded solder, so you may need to 
upgrade your current soldering system. 

 
 
 

Warranty 

 
All products manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a 
period of one (1) year from date of shipment. DX Engineering’s sole obligation under these warranties shall be to issue 
credit, repair or replace any item or part thereof which is proved to be other than as warranted; no allowance shall be 
made  for  any  labor  charges  of  Buyer  for  replacement  of  parts,  adjustment  or  repairs,  or  any  other  work,  unless  such 
charges  are  authorized  in  advance  by  DX  Engineering.    If  DX  Engineering’s  products  are  claimed  to  be  defective  in 
material or workmanship, DX  Engineering  shall, upon prompt  notice thereof,  issue  shipping  instructions for return to 
DX  Engineering  (transportation-charges  prepaid  by  Buyer).  Every  such  claim  for  breach  of  these  warranties  shall  be 
deemed to be waived by Buyer unless made in writing. The above warranties shall not extend to any products or parts 
thereof  which  have  been  subjected  to  any  misuse  or  neglect,  damaged  by  accident,  rendered  defective  by  reason  of 
improper  installation,  damaged  from  severe  weather  including  floods,  or  abnormal  environmental  conditions  such  as 
prolonged exposure to corrosives or power surges, or by the performance of repairs or alterations outside of our plant, 
and shall not apply to any goods or parts thereof furnished by Buyer or acquired from others at Buyer’s specifications. 
In addition, DX Engineering’s warranties do not extend to other equipment and parts manufactured by others except to 
the extent of the original manufacturer’s warranty to DX Engineering.  The obligations under the foregoing warranties 
are  limited  to  the  precise  terms  thereof.  These  warranties  provide  exclusive  remedies,  expressly  in  lieu  of  all  other 
remedies including claims for special or consequential damages. SELLER NEITHER MAKES NOR ASSUMES ANY 
OTHER  WARRANTY  WHATSOEVER,  WHETHER  EXPRESS,  STATUTORY,  OR  IMPLIED,  INCLUDING 
WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS,  AND  NO  PERSON  IS  AUTHORIZED  TO  ASSUME 
FOR DX ENGINEERING ANY OBLIGATION OR  LIABILITY NOT STRICTLY IN ACCORDANCE WITH THE 
FOREGOING. 
 
©DX Engineering 2017 
 
DX Engineering

®

, DXE

®

, DX Engineering, Inc.

®

, Hot Rodz

®

, Maxi-Core

®

, DX Engineering THUNDERBOLT

®

, DX 

Engineering Yagi Mechanical

®

, EZ-BUILD

®

, TELREX

®

, Gorilla Grip

®

 Stainless Steel Boom Clamps, Butternut

®

SkyHawk™, SkyLark™, SecureMount™, OMNI-

TILT

™, RF-PRO-1B

®

, AFHD-4

®

 are trademarks of PDS Electronics, 

Inc. No license to use or reproduce any of these trademarks or other trademarks is given or implied. All other brands 
and product names are the trademarks of their respective owners. 
 
Specifications subject to change without notice.

 

Содержание DXE-ARAH3-1P

Страница 1: ...izontal Active Antenna Used under US Patent No 7 423 588 DXE ARAH INS Revision 3f DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 57...

Страница 2: ...ion 6 Basic Tools Required 6 Manual Updates and Information 6 Installation 6 Location 6 Active Matching Unit 7 Brass Element Blocks 7 Spacers and Rear Mounting Plate 8 Mounting Mast 9 Ground System 9...

Страница 3: ...ted noise interference Most modern LED or LCD flat panel televisions are not broadband noise generators If the noise source is external and single directional in nature using two ARAH antennas in conj...

Страница 4: ...0 dBm This is significantly better than most aftermarket preamplifiers and receivers making it one of the cleanest active antennas on the market reducing or eliminating spurious signals Feedline decou...

Страница 5: ...sformer 120 VAC 60 Hz to 12 Vdc 500 mA Two element connection wires DXE SSVC 2P V Bolt Mounting Clamps and hardware for mounting Additional Items Needed But Not Supplied Mast mounting pipe DXE F6 75 F...

Страница 6: ...pdates and Information Every effort is made to supply the latest manual revision with each product Occasionally a manual will be updated between the time your DX Engineering product is shipped and whe...

Страница 7: ...plates are assembled the orientation may be changed by loosening the mounting hardware and moving the brass blocks to the lower holes and re assembling the hardware Turn the black front mounting plat...

Страница 8: ...ing plate Figure 3 is used between the saddle clamps and the mounting plate assembly as shown The large holes in the front mounting plate Figure 2 are used for tightening the clamp hardware These clam...

Страница 9: ...num Ground System The DX Engineering Horizontal Active Antenna system operates independently from a ground system However steps should be taken to properly protect the mounting mechanism tower etc fro...

Страница 10: ...RCA phono style plug connects to the receiver antenna input See Appendix A for Radio Interface Options Coaxial Cable Feedline Flooded 75 CATV type feedline cable F 6 is strongly recommended for use w...

Страница 11: ...rsus gain response The L jumpers change the inductance values and C jumpers change the capacitance values As shipped all jumpers are deactivated Installing jumpers in L1MF L1HF or both will configure...

Страница 12: ...per function Bench tests on the DXE ARAH3 1P are normally about 60 mA so with some voltage drop on the line 40 to 50 mA should be okay If the measured voltage at the end of the line is under 11 Vdc th...

Страница 13: ...the DXE RFCC 1 Receive Feedline Current Choke will remove common mode signal and noise collected by the shield of the feedline in order to realize normal signal to noise improvements available from a...

Страница 14: ...Every radio manufacturer and every amateur radio operator s location is different The following is only a suggestion and you should consult your radio manufacturer s manual for details and further re...

Страница 15: ...15 ARAH system located greater than 1 2 wavelength from any transmitting antenna connected to a transceiver with a receive input...

Страница 16: ...system located between 1 10 wavelength and 1 2 wavelength from the transmitting antenna connected to a transceiver with a receive input using the DXE TVSU 1A Time Variable Sequencer Unit for proper s...

Страница 17: ...able preparation Connector to cable retention of 40 lbs minimum Superb impedance match to 1 GHz Manufactured of high quality 360 brass cadmium plated for maximum corrosion resistance UV resistant plas...

Страница 18: ...ammed from 300 to 1000 Hz in 50 Hz steps front panel headphone jack with adjustable volume Supports CW full break in Can control external power to our Active Receive Antennas and permit operation in c...

Страница 19: ...or grounding Low noise receive antennas are traditionally located away from electrical wiring and other noise sources Unfortunately noise and other unwanted signals have a direct path to your low nois...

Страница 20: ...iting The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or neglect damaged by accident rendered defective by reason of improper installatio...

Отзывы: