Dwyer Instruments F7 Series Скачать руководство пользователя страница 1

SWITCH ACTION (Normally open/Normally closed)
Vertical Models

Vertical mount models are shipped with normally open switch contacts which close
as the float rises toward the mounting threads. Reverse switch action by removing
the float, rotating it end-for-end and replacing it on the stem.

Horizontal Models

Contacts in horizontal models F7-HPS-1 (internal mount) and F7-HPS-2 (external
mount), are normally open when the float is down and normally closed when the
float is up. Models F7-HPS-1 and -2 also have indicating arrows on the stem end
to confirm float alignment. See installation notes on reverse. Horizontal model F7-
HSS  is  in  the  normally  open  position  when  the  indicating  arrow  points  up,  and
normally closed when the arrow points down.

INSTALLATION

Choose a location away from fill pipes, drains, or other areas where turbulence or
wave  motion  might  occur.  Turbulence  will  cause  false  actuations  and  shorten
contact life. Excess contaminants in fluid may inhibit float operation and occasional
wipe-down  may  be  necessary.  Care  should  be  taken  that  switches  are  always
operated within electrical ratings. Read and understand all safety precautions on
back of this sheet before installing.

MOUNTING

Install  vertical  mount  models  in  an  appropriate  1/8˝  NPT  fitting.  Vertical  models
mount  internally,  oriented  within  30°  of  vertical,  or  select  optional  fittings  for
external mounting. Model F7-HPS-1 must be mounted internally, which means the
switch  must  be  secured  to  the  wall  of  the  tank  or  vessel  from  the  inside.  Install
horizontal model F7-HPS-1 in a 5/8˝ (16 mm) hole and secure with nut provided.
Tank wall should not exceed 1/8˝ (3 mm). Model F7-HPS-2 requires a horizontal
1/2˝ NPT(F) fitting and can be fitted to the tank or vessel from the outside. Model
F7-HSS  requires  a  horizontal  1/2˝  NPT(F)  fitting  and  can  be  mounting  from  the
inside or outside (internally or externally) of the tank or vessel. 

Series F7 Liquid Level Switches 

Bulletin E-75

PIPE

COUPLING

ELBOW

PIPE

DWYER INSTRUMENTS, INC.   

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.     Fax: 219/872-9057

e-mail: [email protected]

SPECIFICATIONS
Electrical Rating (Maximum):

F7-SB, SS2: 

AC: 25 VA, 1A @ 200 V.
DC: 10W, 1A @ 200V.

F7-PP, BT, HSS: AC: 30 VA, 0.14A @ 200V.

DC: 0.28A @ 24 V, 0.07A @ 120V.

F7-MPP: 

10 VA, 0.1A @ 120 VAC.

F7-MPP-NO: 

50 VA, 0.2A @ 240 VAC.

F7-HPS: 

15 VA, 1A @ 220 VAC/DC.

Mounting Connections:

1/8˝ NPT(M) (all vertical mount), 1/2˝ NPT(M) (F7-HPS-

2, F7-HSS), M16 x 2 (F7-HPS-1).

Wire Leads: 

F7-SB, SS2, PP, BT: 22 AWG x 18˝ (46 cm); F7-MPP, HSS: 22

AWG x 24˝ (61 cm); F7-HPS: 22 AWG x 39˝ (1m).

Enclosure Rating:

F7-HSS: Explosion-proof, Class 1, Groups A, B, C, D; Class

II, Groups E, F, G; Class III.

Weight: 

F7-SB, 2 oz. (58 g); F7-SS2, 1.2 oz. (34 g); F7-PP, 0.8 oz. (23 g); F7-

BT, 0.7 oz. (20 g); F7-HPS-1, 1.5 oz. (43 g); F7-HPS-2, 2 oz. (57 g); F7-HSS, 3
oz. (94 g); F7-MPP, 0.8 oz. (23 g).

(Model F7-SB Shown) 

Model

F7-SB
F7-SS2
F7-PP
F7-BT
F7-MPP

(A) Stem
Length

2.75 (70)
2.06 (52)
2.18 (55)
2.18 (55)
1.63 (41)

(B) Float
Diameter

1.13 (29)
1.0 (25) 
1.18 (30)
1.18 (30)
0.63 (16)

(C) Float
Height

1.38 (35)
1.0 (25)
1.0 (25)
1.0 (25)
0.63 (16)

(D) Actuation
from HEX

1.0 (26)
0.73 (19)
0.69 (18)
0.69 (18)
0.47 (12)

Model
Vertical Mount

F7-SB

F7-SS2

F7-PP

F7-BT

F7-MPP

Horizontal Mount

F7-HPS
-1, -2
F7-HSS

Material 
Float/Stem

Buna-N & Epoxy/316SS

316SS (CYC)/316SS

Polypropylene &
Epoxy/Polypropylene
Buna-N & Epoxy/PBT*

Polypropylene /
Polypropylene

Polysulfone/
Polysulfone
316SS/316SS

Max 
Temp.

220°F
105°C
300°F
149°C
220°F
105°C
220°F
105°C
176° F
80° C

185°F
85°C
392°F
200°C

Max 
Press.

150 psig
10 bar
450 psig
31 bar
100 psig
6.89 bar
150 psig
10 bar
100 psig
6.89 bar

150 psig
10 bar
300 psig
20.7 bar

Min
S.G.

0.60

0.75

0.60

0.45

0.90

0.85

0.60

Approx.
Deadband

1/16˝
2 mm
1/16˝
2 mm
1/8˝
4 mm
1/8˝
4 mm
1/8˝
4 mm

3/16˝
5 mm
1/8˝
4 mm

Dimensions, Inches (mm)

*PBT - Polybutylene Terephthalate

Optional Fittings (for Exterior Mounting of Vertical Models)
A-347,

1/8˝ x 1-1/4˝ NPT C.S. Adapter.

A-347-SS,

1/8˝ x 1-1/4˝ NPT 316SS Adapter.

A-348,

1/8˝ x 1-1/2˝ NPT C.S. Adapter.

A-348-SS,

1/8˝ x 1-1/2˝ NPT 316SS Adapter. 

13/16 [20.62]

DIA. MAX.

1-33/64

[38.48]

40

 MAX

3-15/32 [88/09]

M16X2

SWITCH CLOSED
POSITION

2-15/64 [56.74]

SWITCH OPEN 
POSITION

13/16 [20.62]
MAX

1-19/32

[40.46]

40

 MAX

SWITCH CLOSED POSITION

3-7/16 [87.29]

2-23/64 [59.92]

2 [50.80]

1/2 NPT

SWITCH OPEN 

POSITION

3/4

[19.05]

13/16 MIN

[20.6]

22 AWG
LEAD WIRES

1/2-14 NPT

4-5/8 MAX

[116.8]

APPROXIMATE

ACTUATION LEVEL

FITTING

CENTERLINE

3/32

[2.54]

1-7/32 MAX

[31.0]

1-5/32 MAX

[29.2]

C

B

D A

EXTERNALLY

WELDED FLANGE

F7-HPS-2, INTERNAL HORIZONTAL MOUNT

F7-HPS-2, EXTERNAL HORIZONTAL MOUNT

Specifications - Installation and Operating Instructions

F7-HSS

1.800.868.7495

QualityInstruments-Direct

.ca

Отзывы: