5. Name your logger and select the temperature scale, sample rate, and
transmission rate.

6. Set high and low alarms.

DISPLAY

On  the  home  screen,  the  models  show  the  current  temperature  and
humidity  reading.  Models  DW-WIFI-T,  DW-WIFI-TP,  and  DW-WIFI-TC
display  the  temperature  only.  DW-WIFI-TH  displays  temperature  and
humidity on the same screen.

By  pressing  the  button,  the  logger  will  cycle  through  the  different
screens, which are:
1. Home Screen – Current temperature and/or humidity
2. Maximum Recorded Value
3. Minimum Recorded Value
4. Signal Strength
5. Data Syncing

To view detailed information and graphical data, open the configuration
software and click on the “View Sensors” icon.

Other  icons  shown  on  the  home  screen  include  network  connection,
alarm, max/min, and battery.

Network Connection:
Not Displayed: The logger has not yet been set up and configured to a
Wi-Fi network.
Flashing: The logger is not communicating with the software.
Solid: The logger is successfully communicating with the software.

Max/Min:
Shown on their respective pages.
Both are displayed on home page.

Battery:
Not Displayed: Battery is okay.
Flashing: Battery is low.
Solid: Battery is charging.

CHANGING DATA LOGGER SETTINGS

Open the software package and click on the “View Sensors” icon. Select
the logger you would like to modify settings for and click on the “Adjust
Sensor Settings” icon. The software will guide you through the options
that can be altered.

RECHARGING THE BATTERY

When recharging the battery, connect the data logger to a PC or a 5V
power  adapter  via  the  provided  USB  cable.  The  battery  icon  will
disappear when the logger is fully charged.

REPLACING THE BATTERY

If the battery must be replaced, it is required that it be sent to the factory
for replacement. The battery must not be in the unit when it is sent back.
Please follow these directions to remove the battery.

1.  Using  a  size T6  torx  screwdriver,  remove  the  four  hex  screws  from
each corner.
2.  Remove  the  back  piece,  being  careful  not  to  tear  the  white  ribbon
connecting the circuit board to the back piece.
3. The battery is connected to the circuit board via a red and a black cord
that  are  plugged  into  CON1.  Carefully  disconnect  the  battery  and
dispose as appropriate.
4. Reassemble the housing as before.
5.  Contact  customer  service  to  receive  a  Return  Goods  Authorization
number before shipping the product back for battery replacement.

MAINTENANCE/REPAIR

Upon final installation of the Series DW-WIFI, no routine maintenance is
required.  The  Series  DW-WIFI  is  not  field  serviceable  and  should  be
returned  if  repair  is  needed.  Field  repair  should  not  be  attempted  and
may void warranty.

WARRANTY/RETURN

Refer  to  “Terms  and  Conditions  of  Sale”  in  our  catalog  and  on  our
website.  Contact  customer  service  to  receive  a  Return  Goods
Authorization  number  before  shipping  the  product  back  for  repair.  Be
sure  to  include  a  brief  description  of  the  problem  plus  any  additional
application notes.

©Copyright 2014 Dwyer Instruments, Inc.

Printed in U.S.A. 4/14

FR# R1-444114-00 Rev. 3

DWYER INSTRUMENTS, INC. 

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. 

Fax: 219/872-9057

e-mail: [email protected]

Settings can be adjusted while connected to the PC or over

Wi-Fi.

NOTICE

Network

Connection

Alarm

Max and Min

Indicators

Battery

Indicator

Отзывы: