Model:89088
INSTRUCTION MANUAL
MINI TYPE THERMO-ANEMOMETER
www.
.com
[email protected]
1.800.561.8187
Страница 1: ...Model 89088 INSTRUCTION MANUAL MINI TYPE THERMO ANEMOMETER www com informati 87 ...
Страница 2: ... The meter x 1 CR2032 battery x 1 Operation manual x 1 Wrist strap x 1 Plain box x 1 Pouch x 1 Temp Windchill Averaging LCD display is updated every second Windspeed Moving 2 sec average with maximum 2 second average LCD is updated every second Temperature sensor Sealed precision thermister Shock proof housing One button data hold operation Records maximum reading o o Unit C F switchable Replaceab...
Страница 3: ... 7 Wrist strap holder DESCRIPTION Accessory included Wrist strap Battery CR2032 Manual Pouch UNITS CONVERSION TABLE mph km hr knots ft min m s 1 km hr 0 6222 1 0 54 54 69 0 2778 1 mph 1 1 6071 0 8679 87 89 0 4464 1 ft min 0 00508 0 01138 0 01829 0 00987 1 1 m s 196 87 1 944 3 6 2 24 1 1 knot 1 1523 1 8519 1 101 27 0 5144 www com informati 87 ...
Страница 4: ... 8 KNT 0 1 1 1 20 0 M S 0 1 0 8 72 0 KMH 0 1 1 8 Beaufort 1 Temperature range Res o 0 50 C 0 1 o 32 122 F 0 1 Temperature accuracy Battery Life 48 hours continuous use meter per second Feet per minute Knot M S FT M KNT KMH M H BF NOTE 24mm Kilometer per hour Beaufort Mile per hour Air velocity display Update every second Response time 1 min Temperature response LCD update every sec and display eve...
Страница 5: ...is the unit of temperature the maximum air velocity since powered on To freeze the latest display Low battery reminder KEYPAD This meter can be operated by pressing two keys Press to turn on the meter Press more than 3 seconds to turn off the meter In normal mode press to freeze the readings In power off mode press more than 3 seconds to disable the auto sleep mode 4 www com informati 87 ...
Страница 6: ...he unit of wind speed and the primary display indicates the value Fig 2 Fig 1 POWER ON Fig 2 By pressing and holding the key more than 3 seconds to power off the meter TAKING MEASUREMENTS Hold the meter and target the air source from the rear of the unit When holding the meter hold it at arm s length and away from your body In normal mode press to display different modes in turns Velocity Max Velo...
Страница 7: ...ake sure you are in temp mode see above section for mode switching Press and simultaneously to change the units of measurement o The meter defaults F Fig 4 5 TEMPERATURE Press Fig 4 Fig 5 The default display mode is air velocity To change the display mode to air temp Press key repeatedly until LCD changes to air temperature When re powered on the meter will stay at the mode which you last selected...
Страница 8: ...ig 11 The temperature display will now factor in the wind chill To return to normal operation press key again and WCI icon will disappear repeatedly WIND CHILL INDICATOR Fig 11 Fig 10 To freeze the reading press the key while taking measurements will appear on LCD and the reading is frozen To return to normal operation press key again Fig 8 9 DATA HOLD Fig 8 Fig 9 7 Air velocity Air temperature ww...
Страница 9: ...rtment cover by turning it in a CLOCKWISE direction Dispose of the lithium battery in accordance with local state or national waste disposal codes BAT 2032 OPEN Fig 13 The meter will automatically shut down to preserve battery life after 5 minutes of inactivity To cancel this function press and hold more than 3 seconds before turning on Now LCD will display n and then release key The meter default...
Страница 10: ...lay is blurred TROUBLE SHOOTING 1 Power on but no display a Make sure the time of pressing key is 0 1 second B Check the batteries are in place with good contact correct polarity c Replace battery or move away the battery for one minute and re install 2 Display disappear a Replace a new battery b Disable the auto power off function before power on for long time using 3 Err The temp related compone...
Страница 11: ...C EN61000 4 2 1995 A1 A2 2001 EN61000 4 3 2006 the meter complies with the essential protection requirements of Council Directive 2004 108 EC on the approxi mation of the laws of the Member States relating to electromagnetic compatibility 10 WARRANTY The meter is warranted to be free from defects in material and workmanship for a period of two years from the date of purchase This warranty covers n...