background image

 

 

 

1. 

 

SAFETY MEASURES 

 

 

Before starting the pump, read this instruction booklet carefully and keep it in a safe place 
for future reference. 

For safety reasons, the pump must not be used by anyone who has not read these instructions. 
The pump must not be used by anyone under 16 years of age or by anyone who has not read 
and understood the present instruction booklet. Keep children well away from the pump when 
in operation.. 

 

 
The power cord or floating switch must never be used to carry or move the pump.  
Always use the pump’s handle. 

 

 
When handling the pump, while it is connected to the electric power supply, you should avoid 
all contact with water. 

 

 
Never remove the plug by pulling on the power cord. 

 

 
Before taking any action on the pump, always remove the plug from the power socket. 

 

 
There should be no individuals present in the liquid that is being pumped while the pump is in 
use. 

 

 
If the power supply cord has been damaged, it must be replaced by the manufacturer or his 
authorized customer support service in order to avoid all risks. 

 

  The pump is equipped with a thermal overload safety device. In the event of any overheating of 
the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 
minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is 
essential to identify and deal with the cause of the overheating. See Troubleshooting.  
 

 

2. 

 

USE  

 
 

 

 

Multi-purpose Submersible pumps for drainage and garden ponds to create waterfalls and 
fountains  

The pumps are designed to pump clean water or water containing solids with a diameter up to 

1/4 “  

 

 
The temperature of the fluid being pumped must never exceed 95°F 

 

 
The pump must not be used to pump salt water, sewage, flammable, corrosive or explosive 
liquids (e.g. petroleum oil, petrol, and thinners), grease, oils or foodstuffs. 

 

 
Comply with the rules and regulations of the local water authority when using the pump for the 
supply of domestic water. 

 

3. 

 

STARTING THE PUMP 

 

 
Given the different provisions applicable to the safety of electric systems in different countries, 
make sure that the pump system, as concerns its intended use, is in accordance with current 
legislation. 

 

 
Before starting the pump, make sure that: 

 

• 

The voltage and frequency specified on the pump’s nameplate coincide with those of the 
available power supply; 

 

• 

there are no signs of damage to the pump or its power cord;  

 

• 

The electric connection is made in a dry place, protected against any risk of flooding; 

 

• 

The electric system is complete with a residual current circuit-breaker GFI Ground fault Indicator   
(30 mA) and an efficient earthing connection; 

Содержание DAB LEADER ECOSUB Series

Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE ECOSUB ...

Страница 2: ......

Страница 3: ...CONTENTS page 1 SAFETY MEASURES 1 2 USE 1 3 STARTING THE PUMP 2 4 RECOMMENDATIONS 2 5 TROBLESHOOTING 3 6 DISPOSAL 4 7 GUARANTEE 4 ...

Страница 4: ...is roughly 15 to 20 minutes then the pump automatically comes on again If the overload cutout is tripped it is essential to identify and deal with the cause of the overheating See Troubleshooting 2 USE Multi purpose Submersible pumps for drainage and garden ponds to create waterfalls and fountains The pumps are designed to pump clean water or water containing solids with a diameter up to 1 4 The t...

Страница 5: ...mersed in water If the water runs out the pump must be stopped immediately by removing the plug from the power supply Pay careful attention when the pump is operated in manual mode The pump must be placed in a stable position inside a trap or in the lowest part of the place where it is installed The float must be able to move freely while the pump is in operation so the recommended dimensions for ...

Страница 6: ...A Remove the obstruction B Replace the impeller or remove the obstruction The pump does not stop A The pump is not disabled by the float A Make sure the float can move freely The flow rate is too low A Make sure the suction grid is not partially clogged B Make sure the impeller or delivery pipe are not partially clogged or fouled A Remove any obstructions B Remove any obstructions The pump stops r...

Страница 7: ...een used correctly and in compliance with the instnictions The guarantee becomes null and void in the event of the following unauthorized attempts to repair the appliance unauthorized technical changes to the appliance use of non original spare parts manhandling inappropriate use e g for industrial purposes The guarantee does not cover parts liable to rapid wear and tear For any action under guara...

Страница 8: ...5 DAB PUMPS INC 3226 BENCHMARK DRIVE LADSON SC 29456 USA TEL 1 843 797 5002 FAX 1 843 797 3366 ...

Отзывы: