Appendix
21
A.2.
Connecting Leads to a Spring Clamp Terminal Block
The unit is delivered with two terminal block connectors. The connectors enable you to connect
wires for either relay output or alarm input and then connect them to the unit.
Figure 12: Spring Clamp Terminal Block
To connect a wire to the spring clamp terminal block
1.
Strip the insulation form the end of each wire that is to be connected to the terminal
block. Approximately 1 cm (2.54”) of wire should be exposed.
2.
With a small screwdriver, press in and hold the orange spring clamp button next to the
female outlet where the wire will be inserted.
3.
Insert the stripped end of the wire into the female outlet.
4.
Release the orange spring clamp button.
Figure 13: Connecting a Wire to a Terminal Block