These include Tempervent air warmers, Integrated Heat
Transfer and Automatic Summer Ventilation.
To access the optional features (if fitted)
Touch Settings icon then –
INSTALLED OPTIONS > HEAT
TRANSFER
or
AUTO SUMMER VENT
or
TEMPERVENT
> ENABLE
or
DISABLE
On the “control screen” choose the method of control you
wish to use and go through each step to set the control
parameters –
EXIT > EXIT
Some guidance on optional feature settings
The system will give you the ability to control the optional
feature(s). These can include running the feature for a
short period of time as and when you need to. This is called
a Manual option. Alternatively, you may wish to run the
optional feature(s) at a set time every day or night. This is
called a Timer option. If you select this control option, you
will then be asked to set up the timer appropriately. There
is also the ability to activate the optional feature(s) using
temperature as the activation method. If you choose that
option, you will then be asked to set the temperature and
so on. Of course, you are also able to have a combination of
both temperature and time. All of these control settings are
programmable by you in the Control Screen.
Recommended settings for optional features
Tempervent Air Warmer
In Cooler months –
ENABLE
(touch the Enable/Disable slide
switch icon to change to Enable)
> CONTROL
: = Temp &
Timer (Set temp to 8
o
C) + Timer (ON 2100 / OFF 0700) - Fan
Speed = (MED).
Note: This limits the time on and the air supply temperature
below which the feature will operate.
Tempervent Air Warmer
In Warmer months – OFF
Integrated Heat Transfer
In Cooler months - ON - Mode = Temp (25
o
C) + Timer (ON
1800 / OFF 2300) - Fan Speed = (MAX)
Note: This sets the warm room temperature above which the
feature will operate and limits the time period it will operate
in.
Integrated Heat Transfer
In Warmer months - OFF
Auto Summer Vent
In Cooler Months - OFF
Auto Summer Vent
In Warmer Months - ON - Mode = Temp - Fan Speed = (MAX)
Note: Feature operates on the main system ‘Set
Temperature’. It will use outside air to try and maintain the
Set Temperature if the outside air is cooler.
Fan Speed Setting
The Fan Speed setting you choose for the above optional
features is the fan speed the system will run at when the
optional feature(s) is activated.
Fan Burst
Purges the system of cooler or warmer air. This function is
not needed if feature fan speed is set to MAX. This function
is only applicable to Integrated Heat Transfer and Auto
Summer Vent options.
Other Settings
The recommended settings for optional features above have
proven to provide optimal operation for those features. You
can choose alternative modes of operation and settings
within the settings menus for each optional feature.
If system performance reduces, please revert to the
recommended settings or call us on 0800 387 387
Optional Features
For further assistance please call DVS
®
on
0800 387 387
5