background image

These include Tempervent air warmers, Integrated Heat 
Transfer and Automatic Summer Ventilation.

To access the optional features (if fitted)

Touch  Settings icon    then – 

INSTALLED OPTIONS > HEAT 

TRANSFER 

or

 AUTO SUMMER VENT 

or

 TEMPERVENT

 

> ENABLE

  

or 

DISABLE

 

On the “control screen” choose the method of control you 
wish to use and go through each step to set the control 
parameters – 

EXIT > EXIT

Some guidance on optional feature settings

The system will give you the ability to control the optional 
feature(s). These can include running the feature for a 
short period of time as and when you need to. This is called 
a Manual option. Alternatively, you may wish to run the 
optional feature(s) at a set time every day or night. This is 
called a Timer option. If you select this control option, you 
will then be asked to set up the timer appropriately. There 
is also the ability to activate the optional feature(s) using 
temperature as the activation method. If you choose that 
option, you will then be asked to set the temperature and 
so on. Of course, you are also able to have a combination of 
both temperature and time. All of these control settings are 
programmable by you in the Control Screen.

Recommended settings for optional features

Tempervent Air Warmer

In Cooler months – 

ENABLE

 (touch the Enable/Disable slide 

switch icon to change to Enable) 

> CONTROL

: = Temp & 

Timer (Set temp to 8

o

C) + Timer (ON 2100 / OFF 0700) - Fan 

Speed = (MED).

Note: This limits the time on and the air supply temperature 
below which the feature will operate.

Tempervent Air Warmer

In Warmer months – OFF

Integrated Heat Transfer

In Cooler months - ON - Mode = Temp (25

o

C) + Timer (ON 

1800 / OFF 2300) - Fan Speed = (MAX)

Note: This sets the warm room temperature above which the 
feature will operate and limits the time period it will operate 
in.

Integrated Heat Transfer

In Warmer months - OFF

Auto Summer Vent

In Cooler Months - OFF

Auto Summer Vent

In Warmer Months - ON - Mode = Temp - Fan Speed = (MAX)

Note: Feature operates on the main system ‘Set 
Temperature’. It will use outside air to try and maintain the 
Set Temperature if the outside air is cooler.

Fan Speed Setting

The Fan Speed setting you choose for the above optional 
features is the fan speed the system will run at when the 
optional feature(s) is activated.

Fan Burst

Purges the system of cooler or warmer air. This function is 
not needed if feature fan speed is set to MAX. This function 
is only applicable to Integrated Heat Transfer and Auto 
Summer Vent options.  

Other Settings

The recommended settings for optional features above have 
proven to provide optimal operation for those features. You 
can choose alternative modes of operation and settings 
within the settings menus for each optional feature. 

If system performance reduces, please revert to the 
recommended settings or call us on 0800 387 387