QUICKGUIDE 

1.1  Control unit 

 
 
 
 

 

Power Switch 

 

Manual Cleaning 

Plug Sensor

 

Plug  
Motor Drumfilter 

Plug 
Circulation Pump 

 

Plug  
Cleaning Pump 

Содержание C22

Страница 1: ...DVS Filtertechniek Aan de Fremme 53 B 6269BK Margraten www dvs filtertechniek com info dvs filtertechniek com QUICK GUIDE v1 4 DVS FILTERSYSTEMS ...

Страница 2: ...ex 1 BASIC REQUIREMENTS 3 1 1 Control unit 4 2 A GRAVITY SYSTEM 5 2 1 Placing the filter system 5 2 2 Set level control 8 3 B PUMP FED SYSTEM 9 3 1 Placing filter system 9 3 2 Set level control 11 4 WATER VALVE PLC 12 ...

Страница 3: ...uld be placed fully level Leave sufficient space around the filter to perform cleaning and maintenance work The filter control should be in a dry area preferably indoors The drive motor must be protected against weather influences The filter system can be used as gravity system or pump fed system IMPORTANT The correct placement and constant water level in the pond are important conditions for opti...

Страница 4: ...4 QUICKGUIDE 1 1 Control unit Power Switch Manual Cleaning Plug Sensor Plug Motor Drumfilter Plug Circulation Pump Plug Cleaning Pump ...

Страница 5: ...e placed fully level The filter should be placed the height of the installation height fig 2 1 above water level installation height is the distance from maximum water level to top of filter Type filter Installation height cm ECO15 16 ECO22 16 PP22 17 PP35 17 PP50 17 PP65 17 PP100 18 PP100n 18 D22 17 D50 12 C22 14 CL15 14 CL22 14 CL35 14 CL50 14 CL65 14 GRAVITY ...

Страница 6: ...QUICKGUIDE Schematic setup of the drum filter Pic 2 1 1 Water level with running pump after rinse short pen 8 cm in water 2 Start rinsing 3 Pond pump switches off 4 Installation height PP is 17 cm GRAVITY ...

Страница 7: ...CKGUIDE Schematic setup of the combi drum filter Pic 2 2 1 Water level with running pump after rinse short pen 8 cm in water 2 Start rinsing 3 Pond pump switches off 4 Installation height CL is 14 cm GRAVITY ...

Страница 8: ...er will be disposed of via the waste water drain until the maximum water level has been reached For more detailed information you are referred to the complete manual This can be found at www dvs filtertechniek com GRAVITY Pic 2 3 Sensor 1 Water level with running pump after rinse short pen 8 cm in water 2 Start rinsing 3 Pondpump switches off Pic 2 4 Float switch ECO models models With PLC control...

Страница 9: ... horizontally the filter should be completely level The drumfilter must be placed 30cm higher than the biochamber the distance from top of the drumfilter to the top of the biochamber is 30cm Schematic setup of the drum filter Pic 3 1 1 Water level with running pump after rinse 2 Start rinsing 3 Pond pump switches off PUMP FED ...

Страница 10: ...10 QUICKGUIDE Schematic setup of the combi drum filter Pic 3 2 1 Water level with running pump after rinse 2 Start rinsing 3 Pond pump switches off PUMP FED ...

Страница 11: ...complete manual This can be found at www dvs filtertechniek com PUMP FED Pic 3 3 Sensor 1 Water level with running pump after rinse 2 Start rinsing 3 Pond pump switches off Pic 3 4 Float switch ECO models models With PLC controller 1 Water level with running pump after rinse 2 Start rinsing ...

Страница 12: ...12 QUICKGUIDE 4 Water Valve PLC Automatic refill Waste cleaning P Pond GUTTER ...

Отзывы: