background image

Step 4 : 

Menu options

 

SETUP CLOCK

Day
Month
Year
Hour
Minutes
Seconds

V2 TAP MENU

Run time
Range
Anti-vandal time
Automatic Purge
Purge run time

TAP MENU

Run Time
Sensor Range
Wave On/Off operation
Anti Vandal Time
Automatic Purge
Purge Run Time
Lock Outs

SHOwER MENU

Run Time
Sensor Range
Wave On/Off operation
Anti Vandal Time
Automatic Purge
Purge Run Time
Lock Outs

URINAL MENU

Pre-Flush Wait
Pre-Flush Time
Main Flush Time
Sensor Range
Automatic Purge
Purge Run Time

BATH MENU

Run Time
Sensor Range
Wave On/Off operation
Anti Vandal Time
Automatic Purge
Purge Run Time
Lock Outs

AUTO FLUSH VALVE MENU

Range
User Detect Time
Dual Detect Time
Flush Time(s)
Walk Away Time
Automatic Purge
Purge Run Time
Lock Outs

wAVE FLUSH VALVE MENU

Flush Type
Flush Time(s)
Range
Automatic Purge
Purge Run Time
Lock Outs

CHLORINATE MENU

Chlorination Time
Abort and Reset

DEFAULT SETTINGS

(Once powered on, the clock and date must 
be reset). 

2 Seconds
5
30 seconds
OFF
1 Minute

2 Seconds
5
OFF
1 Minute
OFF
1 Minute
OFF

1 Minute
2
OFF
Run+10s
OFF
1 Minute
OFF

1 Second
OFF
2 Seconds
5
OFF
4 Seconds

2 Minutes
2
OFF
Run+10s
OFF
1 minute
OFF

5
5 Seconds
20 Seconds
4 Seconds
2 Seconds
OFF
4 Seconds
OFF

Single
4 Seconds
2
OFF
4 Seconds
OFF

1 Minute

OPTIONAL SETTINGS

1 - 31
1 - 12
Current year onwards
0 - 23
0 - 59
0 - 59

2, 5, 10, 20, 30, 40 & 60 Seconds
1-10
30, 60, 75, 90 Seconds & 2 Minutes
OFF, 3, 6, 12, 24, 36 & 48 Hours
30 Seconds, 1, 2, 4 & 8 Minutes

2, 5, 10, 15, 20 & 30 Seconds
1 - 10
ON/OFF
30 Seconds, 1, 2, 4 & 8 Minutes
OFF, 3, 6, 12, 24, 36 & 48 Hours
30 Seconds, 1, 2, 4 & 8 Minutes
OFF, 4, 6, 8 & 10 Ops

30 Seconds, 1, 2, 3, 4 & 5 Minutes
1 - 3
ON/OFF
Run+10s
OFF, 3, 6, 12, 24, 36 & 48 Hours
30 Seconds, 1, 2, 4 & 8 Minutes 
OFF, 4, 6, 8 & 10 Ops

1 & 2 Seconds
OFF, 1, 2 & 3 Seconds
2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds
1 - 10
OFF, 6, 12, 24, 36, 48 & 72 Hours
2, 4, 6, 8 & 10 Seconds

1, 2, 3, 4, 8 & 10 Minutes
1 - 3
ON/OFF
Run+10s
OFF, 6, 12, 24, 36, 48 & 72 Hours
30 Seconds, 1, 2, 4 & 8 Minutes
OFF, 2, 4, 6 & 8 Ops

1-10 
1-10 Seconds
10, 12, 14, 16, 18, 20, 22, 24, 26 & 28 Seconds

2, 2.5, 3, 3.5, 4, 3/4.5, 3/5, 3.5/5.5, 4/6 & 6.5 Secs 

1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5 & 5.5 Seconds
OFF, 3, 6, 12, 24, 36, 48 & 72 Hours
2, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds
OFF, 2-10 Ops

Single or Dual
2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds
1-3
OFF, 3, 6, 12, 24, 36, 48 & 72 Hours
2, 3, 3.5, 4, 4.5, 5, 5.5, 6 & 6.5 Seconds
OFF, 2-10 Ops

1, 2, 3, 4, 5, 10, 20 & 30 Minutes

PP

00

-4

68

  0

11

11

6

NOTE : 

The default settings above can be restored at any time if needed via the 

‘System Settings’ menu on the Programmer.

Отзывы: