-11-
IR Receiver
IR Transmitter
Pin Assignments
+5V Ground
V
CC
IR Out
IR-
IR+
Pin Assignments
Note 6-2:
For best results, it is critical to carefully position the IR Transmitter and IR
Receiver modules. The IR RX module should be placed where the user would typically aim
the remote control. The IR TX module should be placed in close proximity to the IR window
of the device being controlled. The IR TX module includes double-sided tape that can be
used to adhere it in place.
RS-232 Connections
Connect to an RS-232 device on both the TX and RX units to allow serial
communication to pass-through via the optical link. Please refer to
Warning 6-3
regarding wiring recommendations.
RS-232
Tx
Rx
Tx
Rx
GND
RS-232
Device
Note 6-3 – WARNING:
DVIGear recommends that only qualified technical personnel be
permitted to wire the Phoenix connectors as improper wiring can cause equipment damage.
For best results, it is important to use stranded wires and avoid tinning the wire ends as this
can allow them to be removed too easily from the Phoenix receptacles.