34" 864mm
REMOVABLE
SERVICE DOORS (2)
1-1/4" NPT
AIR OUTLET
VARIABLE SPEED DRIVE
E-STOP
CONTROLS WITH
CSC300
CONTROLLER
FRONT & REAR
FORKLIFT ACCESS
22 3/8" 568mm
1638mm
64 1/2"
1537mm
60 1/2"
854mm
33 5/8"
28" 711mm
MODEL
NO.
HP
kW
PRESSURE
PSI
PRESSURE
bar
SCFM
m3/min
NOMINAL
SOUND @
1 METRE
SYSTEM AMP
3-PHASE
WEIGHT
LBS
WEIGHT
kG
200V
230V
460V
575V
H50VSD
50
37.3
100
6.9
200
5.66
69
131
114
57
46
1700
771
125
8.6
186
5.27
145
10.0
170
4.81
INSTALLATION REQUIREMENTS
1. MAINTAIN 1.25M (4FT) DISTANCE FROM WALLS AND OTHER
OBJECTS FOR PURPOSE OF COOLING AND SERVICING
2. COMPRESSOR MUST BE LEVEL AND ANCHORED
TO SOLID LEVEL FLOOR
3. AMBIENT CONDITIONS:
10ºC (50ºF) MIN. 40ºC (104ºF) MAX.
FUSE TABLE
VOLTAGE
PHASE
FUSE TYPE
FUSE AMP
200
3
J
FAST-ACTING
(DFJ/HSJ)
175
230
150
460
70
575
60
SALES-ENGINEERING DRAWING
N.T.S
7/31/17
LT
specifications subject to change without notice.
DESCRIPTION OF DRAWING
DRAWING NO.
SHT NO REV.
NAME OF PROJECT
DRAWN BY CHECKED BY
DATE
SCALE
H50 SCREW COMPRESSOR
IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC. It is not to be used
or reproduced in any manner, nor submitted to other parties for examination without the prior
approval of DV SYSTEMS, INC. DV SYSTEMS, INC. is continually trying to improve its products,
H50VSD
COOLING AIR OUTLET
WITH MOTORIZED FAN
FOR EXHAUST DUCTING
14 13/16" 376mm
759mm
29 7/8"
664mm
26 1/8"
2 13/16"
71mm
REAR ACCESS
PANEL
REMOVABLE
9/16" HOLES ON
4 STEEL FOOT PADS
POWER IN
1-1/2" CONDUIT
OPENING
COOLING AIR INLET
WITH AMBIENT FILTER
25" X16.5" FOR FRESH
AIR DUCTING
26 7/8" 681mm
20 1/8"
510mm
43 3/16"
1096mm
902mm
35 1/2"
64 1/2"
1638mm