Dux RBP1-ABS Скачать руководство пользователя страница 2

2

RBP1 - ’ABS’ Recess Box V1 - 11-007 8/6/11

DIMENSIONS

The Dux Endurance  water heater serial and model numbers on the data plate located on the left hand
side of the appliance MUST BE copied to the sticker on the inside of the RBP1 - ‘ABS’ cover. The serial
and model numbers are required for future service work.

5. Remove the two M5 Nyloc nuts 

 from the  fixing studs 

of the insert.

6. Insert the upper mounting bracket 

 of the Dux Endurance

water heater into the bracket slot 

 located at the top of the

insert.

7. Push the appliance up until the lower mounting bracket 

aligns with the fixing studs 

 and secure in place with the

two M5 Nyloc nuts 

 removed in step 5.

8. Connect the Dux Endurance  water heater in accordance with

the Operation / Installation manual supplied with the water
heater.

9. An approved weatherproof electrical GPO can be fitted on

either side inside the insert in accordance with AS/NZS 3000
Wiring Rules.

10.Commission and test the water heater in accordance with the Operation / Installation manual supplied with the water

heater.

11.Attach the warning sticker that is supplied with these instructions to the front cover of the Dux Endurance  water heater.
12.Install the RBP1 - ’ABS’ cover by aligning it with the RBP1 - ’ABS’ insert (the flue spigot hole is to be uppermost) and

push into place ensuring that the 4 locking clips 

 have engaged securely.

IMPORTANT

3

4

5

6

7

4

3

8

440

446

1086

11

8

1078

1023

69

383

APPROXIMATELY 1 metre

Width 390

H

eight 1

030

ALL MEASUREMENTS ARE IN MM UNLESS OTHERWISE STATED

Centre of noggin

13

0

Centre of noggin

13

0

15

8

12

Отзывы: