Installation Details

Installation Requirements 

This water heater must be installed 
by a licensed tradesperson, and in 
accordance with: 
•  AS/NZS 3500.4 Plumbing and 

Drainage – Heated Water Services.

•  AS/NZS 3000.
•  Local authority regulations.
•  Outside Australia, please refer to 

local plumbing and building codes 
and regulations.

•  Notice to Victorian customers from 

the Victorian Plumbing Industry 
Commission – this water heater 
must be installed by a licensed 
person as required by the 

Victorian 

Building Act

 (1993). Only a licensed 

person will give you a compliance 
certificate, showing that the work 
complies with all the relevant 
Standards. Only a licensed person 
will have insurance protecting their 
workmanship for 6 years. Make sure 
you use a licensed person to install 
this water heater and ask for your 
Compliance Certificate.

Water Supply Pressure

This water heater is designed for direct 
connection to water supply pressures of:

80, 125 and 160 litre models: 
 

- 1,120 kPa

250, 315 and 400 litre models: 
 

- 800 kPa

Where the mains pressure can exceed 
or fluctuate beyond the pressure 
shown above, a pressure limiting 
device (complying with AS 1357) 
must be fitted in the cold water inlet 
supply. This device must be installed 
after the isolating valve and set below 
the pressure shown above. Note that 
during periods of lower demand, water 
pressure may increase.

Caution:

 This water heater delivers 

hot water at temperatures exceeding 
50

°

C. Refer to AS/NZS 3500 and 

local regulations regarding the need 
for additional hot water delivery 
temperature control.

Pool Heating

This water heater must 

not 

be used for 

pool heating.

Содержание ProFlo series

Страница 1: ...6 160S124 160S136 250S136 315S136 315S236 315S248 400S136 400S236 An H at the end of the model number indicates that the water heater is fitted with a hard water anode For advice repairs and service c...

Страница 2: ...0421 Rev K Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 Co...

Страница 3: ...surance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is des...

Страница 4: ...visible Note All models are equipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode The product must be i...

Страница 5: ...moved The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked for adequate performance or replaced at intervals not exceeding 5 years or...

Страница 6: ...y pipework that is not made of copper Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Australian Standard A...

Страница 7: ...isengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no ci...

Страница 8: ...kg 41 51 61 72 93 93 115 115 Element s Sizes kW 1 8 2 4 3 6 1 8 3 6 2 4 3 6 3 6 3 6 2 3 6 or 2 4 8 3 6 2 3 6 Relief Valve Pressure kPa 1400 1400 1400 1000 1000 1000 1000 1000 Temperature C 99 Power Ra...

Страница 9: ...f the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this a hard...

Страница 10: ...to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not b...

Страница 11: ...nditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the po...

Страница 12: ...hwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For example if you have a 315 litre storage tank and yo...

Страница 13: ...off the electricity supply and contact Dux on 1300 365 115 High Electricity Bills Is the Pressure Temperature Relief Valve discharging too much water Is one outlet such as the shower using more hot w...

Страница 14: ...or repair of the Unit other than by an accredited and licensed service agent or technician are not covered Attachment of accessories or use of non genuine replacement parts other than those manufactur...

Страница 15: ...les Service option followed by Hot Water Provide the serial number and model number of the HWS located on the white compliance sticker top side of the tank or side of a Continuous Flow unit Provide fu...

Страница 16: ...re all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this cod...

Отзывы: