Installation and Owner’s Manual – Airoheat Heat Pump
3
H4120 025941 Rev. D
Clearances:
Allow at least 700 mm clearance above
and 150 mm clearance to either side
of the water heater. If possible, allow
1,000 mm above the water heater
to provide clearance to change the
anodes through the top cover. Refer to
Specifications on page 4.
Ensure there are no obstructions placed
on top of the water heater. The area
must also be clear of debris such as
leaves and tree branches.
Water Heater Support:
The water heater must be installed on
a flat, solid supporting surface. The
pipework must not be used to support
the water heater.
Where the water heater is subjected
to wet conditions, a plinth should be
installed under the water heater.
A properly drained safe tray must be
installed where property damage could
occur from water spillage. Refer to
AS/NZS 3500.4 for further information.
Note - the warranty will not cover
damage due to leakage of the water
heater if a properly drained safe tray has
not been installed.
Transport and Handling:
When moving the water heater, it must
be kept as close to vertical as possible
at all times.
Never tilt the water heater more
than 45° from vertical.
Tilting beyond 45° will severely affect the
operation of the water heater and may
void the warranty on the refrigeration
components.
Installation Requirements