Owner’s Manual – Prodigy 5

17

H3109    3109    Rev. E

Dux Hot Water Unit
Manufactured by Dux Manufacturing 
Limited (“Dux”)
Terms of Warranty and Replacement 
Guarantee

All Prodigy 5 water heaters 
manufactured and sold after 1 January 
2012 are backed by a comprehensive 
one (1) year full parts and labour 
warranty (conditions apply – see below). 
Furthermore, the Prodigy 5 tank 
includes a guarantee to replace your hot 
water unit if the inner cylinder fails within 
ten (10) years (conditions apply – see 
below).
The terms of the Warranty and 
replacement guarantee are set out 
below.

1 Year Comprehensive Warranty

Your hot water system and its com-
ponents (“Unit”) are covered by 1 year 
(parts and labour) warranty against 
defective factory materials or workman-
ship. 
This warranty period commences from 
the date of installation of the Unit provid-
ing you have proof of this installation 
date. Where the date of completion of 
installation is not known or cannot be 
proven, then this warranty will com-
mence one (1) month after the date of 
manufacture (refer to the data label on 
the unit).

10 Year Replacement Guarantee

If an inner cylinder fails on a Dux hot 
water unit within a further nine (9) years 
after the end of the initial one (1) year 
warranty period, Dux will provide a 
free replacement hot water unit at the 
nearest approved Dux agent or Dux 
office to the owner’s home. Under this 
replacement guarantee, the transport, 
installation and labour costs of delivering 
the replacement hot water unit and 
removing and replacing the existing 
hot water unit with the replacement hot 
water unit will be the responsibility of the 
owner of the existing hot water unit. 

Conditions of Warranty and Re-
placement Guarantee 

The benefits provided to you by the 
warranty and replacement guarantee 
(collectively “Warranty”) are in addition 
to the guarantees and other rights and 
remedies available to you under the 
Australian Consumer Law (“ACL”). 
If the Unit fails to conform to this Warranty 
during the applicable period, Dux will 
replace any failed component or where 
necessary, in the absolute discretion 
of Dux, replace the Unit free of charge 
including reasonable labour costs incurred 
in normal business working hours.
This Warranty only applies to defects 
which have arisen solely from faulty 
materials or workmanship in the Unit 
and does not apply to other defects 
which may have arisen as a result 
of, without limitation, the following: 

Warranty

Содержание 135D5L

Страница 1: ...135D5L 170D5N 170D5L 5 Star Gas Hot Water Heater H3109 3109 Rev E Installation Details Owner s Information Warranty For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand...

Страница 2: ...1 Installation Details 2 Plumbing Connections 3 Specifications 6 Gas Connections 7 Commissioning Adjustments 8 Owner s Information 12 System Maintenance 14 Troubleshooting 15 Warranty 17 Other Informa...

Страница 3: ...tinuous hot water for all your needs safely economically and for many years to come To be upfront about it we want Dux to be your brand of choice So you can depend on us to provide more than just a ho...

Страница 4: ...uipped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode A properly drained overflow tray must be used where...

Страница 5: ...Building Act 1993 Only a licensed person will give you a compliance certificate showing that the work complies with all the relevant Standards and only a licensed person will have insurance protecting...

Страница 6: ...n the PTR valve at least once every six 6 months Failure to do this may result in problems with the water heater The PTR Valve must not be tampered with or removed The water heater must not be operate...

Страница 7: ...cted to the OUTLET socket on the tank Insulation of Pipes All hot water pipes must be insulated with UV stabilized insulation Temperature Protection All water heaters have the ability to produce hot w...

Страница 8: ...ouse 3 Cold Water Inlet Tank Specifications Model Numbers 135D5N 135D5L 170D5N 170D5L Capacity L 135 170 Net Weight Empty kg 76 88 Relief Valve Pressure kPA 1400 1400 Gas Consumption Propane 22 5 MJ h...

Страница 9: ...Gas piping should be connected through the side of the case see figure below The plastic grommet must be installed around the pipe and clipped into the case The gas control is fitted with a RC 15 soc...

Страница 10: ...ton for up to 40 seconds until the pilot flame ignites Note It is not possible to depress the knob fully if the gas control has activated its safety shut off feature In this case wait 60 seconds for t...

Страница 11: ...selected setting the water may already be at the selected temperature Warning Do not attempt to light if the pilot is out and the knob is in the ON position one of the number settings Follow steps ab...

Страница 12: ...the lower left hand side of the Gas Control 3 3 Light the burner Rotate adjustment screw clockwise to increase or anti clockwise to decrease pressure 4 Replace the plastic cover and securing screw No...

Страница 13: ...ressure If problems are encountered in this process contact the Dux Service Department Failure to accurately set the pressure can result in damage to the water heater and automatically cancels the Man...

Страница 14: ...t a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any other electrical appliance operating nearby If hydrogen is discharged through the tap...

Страница 15: ...umulate in the water heater To dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not a dishwasher clothes washer or other applianc...

Страница 16: ...k to ensure the valve closes correctly Five Year Service By Authorised Personnel Only The five year service must be carried out by a licensed tradesperson It is recommended that this service be carrie...

Страница 17: ...water usage patterns an inexpensive flow control valve can easily be fitted to the shower outlet Consider that during night time heating the time taken to heat the tank can take longer so you may fin...

Страница 18: ...y of water in the heating period Continuous trickle PTR This is most likely due to a build up of foreign matter In this case try gently raising the easing lever on the Pressure Temperature Relief Valv...

Страница 19: ...linder fails on a Dux hot water unit within a further nine 9 years after the end of the initial one 1 year warranty period Dux will provide a free replacement hot water unit at the nearest approved Du...

Страница 20: ...tutory requirements In addition to this Warranty certain legislation including the ACL may give you rights which cannot be excluded restricted or modified This Warranty must be read subject to such le...

Страница 21: ...ent and or excessive labour at the determination of Dux to make the Unit accessible for repair or replacement As required by legislation including under the ACL any claims for damage to furniture carp...

Страница 22: ...reed by you the client and Dux Manufacturing Limited Your Details For future convenience fill in the following details and retain with your original invoice for your own records Surname Given Name s A...

Страница 23: ...Owner s Manual Prodigy 5 21 H3109 3109 Rev E...

Страница 24: ...unning costs Please register for preventative maintenance at For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand www dux com au warranty Please Register Your Water Heat...

Отзывы: