Verify that the automatic filter cleaning works.
Maintenance
It is important that the cyclone's filters are replaced as they can no longer be cleaned effectively. The intervals between the
changes depend entirely on the material being sucked, the flow of the system and the operating time.
Filter replacement
Filters must be changed at least once a year. Depending on operating conditions and shifts, they may need to be replaced more
often. Do not expose unprotected dust to hazardous dust.
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable equipment.
1. Turn off and lock the vacuum producer's circuit breaker.
2. Put on safety gear.
3. Empty the compressed air-tank.
4. Remove the cover of the dust separator.
5. Remove the filters and put them in a plastic bag. Seal the bag.
6. Vacuum filter plate and casing.
7. Put the new filters in place, and put the cover back on the dust separator.
Explosion panel
Information regarding maintenance of the explosion panel can be found in a separate document from the supplier.
Technical data
Technical data
S 11000 X
H x W x D [mm]
2225 x 675 x 625
Weight [kg]
70
Inner diameter [mm]
Ø 477
Inlet [mm]
Ø 108
Outlet [mm]
Ø 108
Maximum recommended air flow [m
3
/h]
1000
Max temperature filter unit [°C]
70
Filter
Filter area [mm]
12
Filter classification
EN 60335-2-69, Klass M
Degree of separation [%]
99,9
Container [l]
50
Max temperature filter [°C]
130
Filter cleaning with reverse air pulse
Compressed air [bar]
4
Hose connection [mm]
6/8
Art no.
1104 (24 V AC)
110400 (24 V DC)
Pressure tank
Filter cyclones
Recommended pressure
Maximum pressure
428801
11000, 11000 X, 11000 EX, 21000, 21000 EX
4 bar
7 bar
434201
32000, 34000, 34000 X, 34000 EX
4 bar
5 bar
S 11000 X, Art no. 99052-A