RAF 500 - 9
Part No 9052
2012-01-20
Description
Dustcontrols fans are so called radial fans. Th
e air is in-
troduced into the fan at the centre of the fan wheel and is
forced outward to the fan housing and through the outlet
by the centrifugal force.
Th
e fans are direct driven with maintenance free motors.
Lubrication points are available on the motor if specifi ed
when ordering.
Th
e fan is equipped with vibration isolators and hith
quality sound insulation. External inline silencing on the
outlet can be installed.
Technical Data
Wall installation
Floor installation
Dimensions RAF 500 without Silencing Enclosure
Dimensions RAF 500 with Silencing Enclosure
kPa Pu
10
8
6
4
2
0
1
2
3
4
5
kW P
200 400 600 800 1000
Q
m
3
/h
Pressure loss
Motor kW
2.5/3.0
Pump RPM
rpm
3000
Weight kg
39
Max dp
kPa
5,6
Max Q
m
3
/h 900
Sound Level*
)
dB(A)
without silencing enclosure
79
with silencing enclosure
66
Inlet/Outlet
mm
108/76
*
)
with exhaust silencer, 1 m
EN
G
L