![Dustcontrol DC F Tromb a Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/dustcontrol/dc-f-tromb-a/dc-f-tromb-a_translation-of-the-original-instructions_2543309010.webp)
c – Plastic bag:
The extracted and separated material is collected in a plastic bag that can be detached in one simple operation.
The material can easily be recycled or disposed of.
a - Container:
A cylindrical container for collection of separated material.
L – Longopac:
The machine is equipped with a flexible bag system, in which the dust is collected in a closed system.
Technical data
DC F Tromb c
DC F Tromb a
DC F Tromb L
HxWxL [mm]
1290 x 600 x 780
1290 x 600 x 780
1290 x 600 x 780
Weight [kg]
27
33
32
Inlet [mm]
Ø76
Ø76
Ø76
Collecting container [l]
20
40
longopac
Technical Data UK/USA/CAN
DC F Tromb c
DC F Tromb a
DC F Tromb L
HxWxD [in]
53,5 x 23,5 x 27,5
53,5 x 23,5 x 27,5
53,5 x 23,5 x 27,5
Weight [lb]
59
73
70
Inlet [in]
3
3
3
Collecting container [l]
20
40
longopac
Operation
Emptying
a – Container
The container underneath the cyclone should be emptied when about 2/3 full.
c – Plastic bag
The plastic bag should be replaced when the dust level is about 5 cm below the discharge flap.
L – Longopac
Close the bag using the supplied cable ties when you believe that it has been filled to a suitable level. Another cable tie is used a
little further up. This forms the bottom of the next bag. The filled bag is then cut off, and the machine is ready to be used again.
Changing the bag magazine
1.
Rotate the holder to the position in which it can be pulled down.
2.
Insert a bag magazine into the holder and refit it.
10
DC F Tromb, Art.nr. 44754 A
ENGLISH