DC 5800c PTFE 5.5 kW - 11
Part No 9475-B
Th
e warranty period for this machine is two years and co-
vers manufacturers faults. Th
e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly. Normal wear is not covered by this warranty.
Warranty
Service performed by other than Dustcontrol or its aut-
horized agent voids automatically the warranty. No other
warranty express or implied is applicable.
EN
G
L
ISH
Problem Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
Thermal overload tripped.
Wait 5 minutes.
The motor stops directly
Incorrect fuse.
Change to
correct circuit.
after starting.
Thermal overload not set
Electrician should adjust.
correctly.
Pump runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
No plastic sack/container
Mount the correct sack/
on the cyclone.
container.
Pump rotation backwards.
Electrician should change
phases.
Pump runs but poor suction. Hole in the hose.
Change or repair hose.
Plugged
fi lter.
Clean or change fi lter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
Machine blows dust.
Filter is perforated or has
Check the fi lters and change
come loose.
if necessary.
Abnormal sound from
Particles in the pump.
Order service.
machine.