DC 5800a 5 kW - 9
Part No 9481
2008-05-21
ENGLISH
Operation
Connect the machine to a suitable power source
by following the specifi cations found on the serial
number plate on the machine. If an extension cord
is to be used with the unit, it should be suitably rated
according to the prevailing electrical code. Check
rotation of the motor at startup. On machines equip-
ped with a phase reverser, incorrect rotation can be
easily changed. Machines not equipped with a phase
reverser will require the service of a qualifi ed electri-
cian to interchange two phases in the power supply.
The fi lter should be cleaned 1-2 times per day with
continuous running, or if the machine is equipped
with a fi lter monitor, when this is in the red area.
For fi lter cleaning:
Description
The DC 5800a is an electric powered vacuum ex-
tractor for use with source extraction, cleaning and
material transportation applications in most types of
industries.
The extraction system functions with negative pres-
sure (vacuum) that draws the air through suction
casings, nozzles, hose systems, separator and fi lter
systems. Coarse separation of dust occurs in the unit’s
1. Start the machine.
2. Close the shutter valve on the machines inlet.
3. With slow, even motion open the pulse top by
lifting the handle. Repeat three to six times.
4. Open the shutter valve.
5. If the fi lter condition meter reads green work
can continue, if in the red, pulse clean again. If
after several repetitions, the fi lter condition still
shows red the main fi lter must be changed.
The container under the cyclone should be emptied
when it is fi lled to ca 2/3.
cyclone which is a highly effi cient separator for larger
particulate. The fi ne dust is separated and contained
by the unit’s fi lter system. Separated material is col-
lected for disposal in the plastic sack or container at
the base of the cyclone.
Filter cleaning with reverse pulse gives long fi lter
life and constant capacity.
When emptying the container, it is unclipped
and removed away from the machine. After
that has be done the sack can be taken out of
the container.
The container is attached to the machine
by two fasteners.