Filter replacement
The
fi
ne
fi
lter should be replaced at least once a
year. HEPA
fi
lters should be replaced after every
300 hours of operation. Wear a dust mask when
replacing the
fi
lter. Only use an original
fi
lter.
Release and lift off the lid. To prevent the escape
of dust, place a plastic sack over the cyclone, and
remove the
fi
lter cartridge. Clean the
fi
lter plate.
Then
fi
t the new
fi
lter.
- CAUTION! Do not reuse the main
fi
lter once it
has been removed from the machine.
The HEPA
fi
lter is removed by withdrawing the car-
tridge after opening the lid. The new
fi
lter cartridge
is placed in the
fi
ne
fi
lter and is sealed by carefully
attaching the lid.
Caution
The manufacturer or a trained person must carry
out an inspection at least annually, e.g. damage to
the
fi
lter, air-tightness of the dust-extraction ma-
chine and the function of the control unit.
The
turbopump
has a very long service life and
requires no maintenance. After approximately
10,000 hours of operation, the radial seal between
the motor and the pump should be lubricated with
bearing grease. The bearings and seals of the
electric motor must be inspected at the same time.
These must be lubricated and replaced, if
necessary. If any other wear is observed, the parts
concerned must be replaced.
Description Part
No.
Suction hose 38, ESD-certi
fi
ed
2027E
Suction hose 50, ESD-certi
fi
ed
2028E
Coupling socket 50/50 ESD-certi
fi
ed 2107E
Connecting sleeve 38/38 turnable
ESD-certi
fi
ed
2114E
Intermediate sleeve 50/38,
ESD-certi
fi
ed
2120E
HEPA
fi
lter DC 3800 H Turbo EX
42024H
Fine
fi
lter, antistatic
DC 3800 H Turbo EX
4202501
Sealing plug, inlet
42250H
Plastic sack, conductive
42384H
Floor nozzle 450 A-38 ESD-certi
fi
ed 7236E
Safety-relevant accessories included
We can supply all safety-relevant spare parts
and wearing parts.
Dustcontrol UK Ltd.
Old Barn, Home Farm
Business Park
Church Way, Whittlebury,
Northants NN12 8XS
Tel: 01327 858001, [email protected],
www.dustcontrol.co.uk
See the Dustcontrol catalogue for other ac-
cessories.
DC 3800 H/5800 Turbo EX can be ordererd
with antistatic accessories to ful
fi
l the require-
ments of the ATEX Zone 22 directive 1999/92
ATEX 137
.