Safety Considerations

Read all instructions before attempting to operate 
this machine and save these instructions.

Warning! 

When using electric machines, basic 

safety precautions should always be followed to 
reduce the risk of 

fi

 re, electric shock and personal 

injury, including the following:

1. Important!

No hot particles nor ignition sources are allowed
to be sucked into the unit. The machine should
not be used for explosives, unstable or pyrop-
horic particles or dust.

– WARNING!

 Operators shall

be adequately instructed on the use of these 
machines.

– WARNING! 

This machine is for

dry use only.

– CAUTION!

 This machine is for

indoor use only.

– CAUTION!

 This machine shall

be stored indoors only.

2.

Work area environment

Don´t expose the machine for rain. Don´t use
it in damp or wet locations or in presence of

fl

 ammable liquids or gases.

3.

Overload

Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos.
Don´t use the machine for purposes that it isn´t
intended for.

4.

Body injuries

Never let the suction come in contact with
parts of the body. The strong suction effect
can hurt the blood-vessels in the skin. Don´t
repair the electric components yourself. The
machine should be serviced by quali

fi

 ed per-

sonnel only. Faults may cause injury. See also
below under warnings.

5.

Don´t abuse cord

Never pull the machine by the cord. Keep the
cord from heat and sharp edges. Check the
electric cable regularly for damage.

6.

Important measure

With cleaning and maintenance on the mach-
ine, the power cable should be dis-connected
from the supply. The machine must not be
washed or cleaned with water.

7.

Maintain the machine with care

Keep the machine clean and check that the
hose is undamaged and that all gaskets are
tight. Follow instructions. Keep handles dry
and free from oil and grease.

8.

Checking for damage

Before futher use of the machine it should be
carefully checked that the machine is unda-
maged. If there are any damaged parts these
should be repaired by a Dustcontrol authori-
zed service center.

If the supply cord is damaged, it must be re-
placed by the manufacturer, its service agent
or similarly quali

fi

 ed persons in order to avoid

a hazard.

9.

Warning

Use only accessories and replacable parts
which are available in the Dustcontrol catalo-
gue.

This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety. Children should be
supervised to ensure that they do not play with
the appliance.

This machine is intended for commercial use
only, for example in hotels, schools, hospitals,
factories,shops, of

fi

 ces and rental businesses.

09 42 68 101

[email protected]

www.everitts.co.nz

Содержание DC 2900a

Страница 1: ...Cleaner Dustcontrol reserves the right to change specifications without notice and is under no obligation to alter previously delivered products Dustcontrol is not responsible for errors or omissions in this catalogue 09 42 68 101 sales everitts co nz www everitts co nz ...

Страница 2: ... 230 V 10 A 1200 W 230 V 16 A 2200 W 120 V 20 A 1200 W Fine filter polyester area 1 5 m2 Degree of separation EN 60335 2 69 Class M 99 9 Filter area microfilter H13 0 85 m2 Degree of separation microfilter EN 1822 1 HEPA H13 EN 60335 2 69 Class H 99 995 Sound level 68 dB A Vacuum producer capacity Always check with local regulations Sound level at 1 6 m height and 1 m distance according to DIN 456...

Страница 3: ...ly waterproof cords are accep table Auto Connect the subject electric tool to the electrical outlet on unit Set the selector switch to the AUTO position The unit will start automatically when the subject tool is started The machine turns off a few seconds after the con nected tool is closed Man For manual start of the unit set the selector switch to the MAN position The DC 2900a c Auto is equipped...

Страница 4: ... x 30 BRB 6 4 x 12 2 SP 2 5 x 25 BRB 13 x 32 42150 13 x 25T 6 3 BRB 13 x 24 Assembly 2 x BRB 13 x 32 T 2 2 x 42150 13 x 25 T 6 2 x BRB 13 x 24 T 2 2 x BRB 6 4 x 12 T 1 5 2 x SP 2 5 x 25 2 x M6S 6 x 30 M6S 6 x 30 BRB 6 4 x 12 2 ...

Страница 5: ...ed with hazardous materials Worn parts must be replaced Filter change Remove the motor head Lift the filter straight up out of the cyclone When required a plastic sack can be placed over the cyclone for dust free filter change The filter is lifted directly into the sack During the filter change check the filter gasket A damaged gasket can allow the release of hazar dous dust Never use old gaskets ...

Страница 6: ... Part No 94164 A 2016 06 16 Service intellibag dust free change of bag step by step 1 2 3 4 Switch ON take out the bag Switch ON put the new sack on Switch ON pulse the filter and run the dust collector Switch ON ...

Страница 7: ...Take off the top and clean cyclone out Machine blows dust Filter is perforated or has Check the filters and change come loose if necessary Abnormal sound from Order service machine TROUBLE SHOOTING Warranty The warranty period for this machine is two years and covers manufacturers faults The warranty is valid under the condition that the machine is used under normal conditions on the task for whic...

Страница 8: ... below under warnings 5 Don t abuse cord Never pull the machine by the cord Keep the cord from heat and sharp edges Check the electric cable regularly for damage 6 Important measure With cleaning and maintenance on the mach ine the power cable should be dis connected from the supply The machine must not be washed or cleaned with water 7 Maintain the machine with care Keep the machine clean and che...