DC 2800c, 9
Art nr 9453
Safety Considerations
Read all instructions before attempting to operate
this machine and save these instructions.
Warning!
When using electric machines, basic
safety precuations should always be followed to
reduce the risk of fire, electric shock and personal
injury, including the following:
1. Work area environment
Don´t expose the machine for rain. Don´t use it
in damp or wet locations or in presence of
flammable liquids or gases.
2. Overload
Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos.
Don´t use the machine for purposes that it isn´t
intended for.
3. Body injuries
Never let the suction come in contact with
parts of the body. The strong suction effect
can
hurt the blood-vessels in the skin. Don´t repair
the electric components yourself, get some-
body qualified. Faults may cause injury. See
also below under warnings.
4. Don´t abuse cord
Never pull the machine by cord. Keep cord
from heat and sharp edges. Check the electric
cable regularly if damage.
5. Important measure
With cleaning and maintenance on the
machine, the power cable should be dis-
connected from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose is
entired and that all gaskets are tight. Follow
instructions. Keep handles dry and free from
oil and grease.
7. Checking of damage
Before futher use of the machine it should be
carefully checked that the machine is unda-
maged. If there are any damaged parts these
should be repaired by of a Dustcontrol authori-
zed service center.
8. Warning
Use only accessories and replacable parts
which are available in Dustcontrol catalogue.
TECHNICAL DATA
HxWxL
990x420x400 mm
Weight
14 kg
Inlet
φ
50 mm
Hose length
5 m
Collecting sack, 11 l
500x550 mm
Flow, max
190 m
3
/h
Neg. pressure, max
21 kPa
Power consumption
1200 W, 220V/110V
Fine filter polyester, area
1.5 m
2
Degree of separation
(DIN 24184/3)
99,9 %
Filter area, microfilter
0.85 m
2
Degree of separation,
microfilter (DOP)
> 99,97 %
Sound level
< 70 dB(A)
0 50 100 150 200 m
3
/h
kPa
Vacuum
producer
capacity
20
15
10
5
ENGLISH