IMPORTANT:

The device  must be installed in compliance
with all national and local electrical and
mechanical codes. Failure to do so will void
ETL safety listing and Dust Free® warranty.

Nomad/Nomad 2 Mounting Options 

(Fig.1)

The Nomad/Nomad 2 is suitable for installa-
tion inside or outside the air handling system
or ductwork. For HVAC applications only.

The Nomad/Nomad 2 may be installed as a
parallel mount, perpendicular mount, or as an
insert mount depending on your requirements.
The included brackets and screws allow the
device to be mounted in any of these orienta-
tions. 

Note: 

For insert-mount applications a 3" hole must be

cut into the duct to allow for the insertion of the lamp
and connector.

Fig. 1

Device may be mounted in a variety of orientations.

Sharp Edge Hazard.

Be careful of sharp edges on device and HVAC equip-
ment while installing the device. Personal injury may
result.

CAUTION

Perpendicular
Mount

Parallel
Mount

Insert
Mount

(Nomad Only)

SPECIAL INSTALLATION NOTES

• Do not install in closet return grille applications.

• 

Do not in outdoor applications.

• 

Do not expose wiring or plastic parts to UV-C light.

• Do not install where UV-C light can be seen

after installation.

• 

Do not install beneath a humidifier.

If the UV device is installed on the inlet side

(return air side) of a coil, make sure that the
HVAC system is configured such that the
blower is located between the return air filter
and the inlet side (return air side) of the coil,
such as would be found in a traditional up-
flow, or horizontal furnace with the coil
placed after the heat exchanger.

• 

If the UV device is installed near an air filter,

check with filter manufacturer for UV-C
resistance properties.

• 

If the desired UV installation location is

intended to irradiate an air filter, to neutralize
the microbiological matter on the air filter
surface, such as would be found in the
return air drop of a basement application or
in the return plenum of a horizontal system
in an attic; take precautions as described in
note above, and make sure the UV fixture is
placed on the return side of the filter. DO
NOT INSTALL THE UV FIXTURE ON EITHER
SIDE OF THE FILTER IN HALL / CLOSET
RETURN AIR APPLICATIONS. 

(See ATTEN-

TION! Warning sheet #212

945

-00).

Содержание BIO-FIGHTER Nomad 9D

Страница 1: ...microorganism or neutralizes its ability to reproduce FEATURES Reduces or prevents mold growth on HVAC coils allowing them to operate at peak efficiency where the light shines Also significantly redu...

Страница 2: ...539 727 6 932 494 6 550 257 Specifications subject to change without notice NOMAD 2 NOMAD SPECIFICATIONS MODEL DIM A DIM B DIM C DIM D Nomad 9D 3 125 7 3 5 9 Nomad 16D 3 125 7 3 5 16 Nomad 2D9 1 5 17...

Страница 3: ...NOTES Do not install in closet return grille applications Do not in outdoor applications Do not expose wiring or plastic parts to UV C light Do not install where UV C light can be seen after installat...

Страница 4: ...d Be careful of sharp edges on device and HVAC equip ment while installing the device Personal injury may result CAUTION Insert Mount If installing the Nomad as an insert mount 1 Make a 3 diameter lam...

Страница 5: ...ifespan CAUTION Mercury Hazard Do Not Break Each UV C lamp contains a small amount of Mercury May cause redness or irritation Use proper disposal techniques in case of breakage See page 6 WARNING Inse...

Страница 6: ...STALL REMOTE DOOR INTERLOCK SWITCH Optional accessory 06150 Mount the remote door interlock switch so that power to the device is automatically discon nected anytime the air handler access panel is op...

Страница 7: ...ues in case of breakage WARNING LAMP REPLACEMENT Annually The lamp should be replaced annually even if it appears to be operating normally UV C energy production diminishes over time 1 Obtain the corr...

Страница 8: ...D DUST FREE LP EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES WHETHER WRITTEN OR ORAL IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY WORKMAN SHIP OR FITNESS FOR A PARTIC...

Отзывы: