Durr Dental A949444000 Скачать руководство пользователя страница 1

EN

Power Tower View

Installation and operating instructions

A949100052L02

*A949100052L02*

2104V003

Содержание A949444000

Страница 1: ...EN Power Tower View Installation and operating instructions A949100052L02 A949100052L02 2104V003 ...

Страница 2: ......

Страница 3: ...uirements 13 6 1 Pipe materials 13 6 2 Hose materials 13 6 3 Installation and routeing of hoses and pipes 13 6 4 Information about electrical con nections 13 6 5 Information about connecting cables 14 7 Installation 14 7 1 Combining devices safely 14 7 2 Setting up and connecting the lower part of the cabinet 14 7 3 Mounting the upper part of the cabinet 16 7 4 Installing the compressor units 16 7...

Страница 4: ...2 Tips for operators and service techni cians 26 Appendix 13 Connection media plan 27 14 Electrical connection plan 28 14 1 Version 400 V 3N 28 15 Menu structure 29 15 1 Settings 29 Contents 2 A949100052L02 2104V003 EN ...

Страница 5: ...oltage The warnings are structured as follows SIGNAL WORD Description of the type and source of danger Here you will find the possible conse quences of ignoring the warning Follow these measures to avoid the danger The signal word differentiates between four levels of danger DANGER Immediate danger of severe injury or death WARNING Possible danger of severe injury or death CAUTION Risk of minor in...

Страница 6: ...ns of all guidelines laws and other rules and regula tions applicable at the site of operation for the operation of this unit Check the function and condition of the unit prior to every use Do not convert or modify the unit Comply with the specifications of the Installa tion and Operating Instructions The Installation and Operating Instructions must be accessible to all operators of the unit at al...

Страница 7: ...ability for damage occurring dur ing transport due to the use of incorrect packaging even where the unit is still under guarantee Only transport the unit in its original packaging Keep the packing materials out of the reach of children 2 6 Disposal The unit must be disposed of properly Within the European Union the unit must be disposed of in accordance with EU Directive 2012 19 EU WEEE If you hav...

Страница 8: ...S 400 V Duo unit 20 l pressure tank Universal membrane dryer 3 2 Optional items The following optional items can be used with the device Pressure reducer 6040 992 00 Amalgam separator 7805 100 50 Compressor unit A949300060 3 3 Wear parts and replacement parts The following working parts must be replaced at regular intervals refer also to Maintenance these articles do not bear the CE mark Air intak...

Страница 9: ...t an ambient temperature of 40 C At an ambient temperature of 40 C noise level in accordance with ISO 3744 At an ambient temperature of 35 C noise level in accordance with ISO 3744 Current reduction without optional items Current reduction without CA 4 amalgam separator A 0 2 Current reduction without second Duo unit A 2 5 Connections Vacuum connection external mm Æ 50 Exhaust air connection exter...

Страница 10: ...l m 2000 4 1 PTV A949444000 and A949443000 with second Duo unit and CA 4 General technical data Weight kg 275 Operating mode S1 Delivery at 5 bar 0 5 MPa l min 195 Electrical data Nominal current at 10 bar 1 0 MPa A 9 0 4 2 PTV A949454000 and A949453000 with second Duo unit General technical data Weight kg 265 Operating mode S1 Delivery at 5 bar 0 5 MPa l min 195 Electrical data Nominal current at...

Страница 11: ...4 3 Type plate The type plate is located at the bottom right of the housing Product description A949100052L02 2104V003 9 EN ...

Страница 12: ...eld Head of Research and Development The address is identical to the address of the manufacturer Low voltage guideline 2014 35 EU in its valid version Electromagnetic Compatibility EMC Directive 2014 30 EU in its current version Directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment in its current version Power Tower View REF A9494...

Страница 13: ... unit 4 Pressure equalisation tank 5 Compressor unit 6 Pressure tank 7 Touch display 5 2 Dry suction system 2 3 1 4 5 6 7 1 Main power switch 2 Drying unit 3 Suction unit 4 Condensation separator 5 Compressor unit 6 Pressure tank 7 Touch display Product description A949100052L02 2104V003 11 EN ...

Страница 14: ... appropriate level of soundproofing The unit is operated via a touch display and indicates the various parameters of the individual components 5 4 Touch display 1 2 1 Touch display 2 Main power switch The touch display shows unit data operating sta tuses and messages and user dependent unit settings can be configured Product description 12 A949100052L02 2104V003 EN ...

Страница 15: ...gns of ageing over time Therefore they should be inspected regularly and replaced as nec essary The following types of hoses must not be used Rubber hoses Hoses made completely of PVC Hoses that are not sufficiently flexible 6 3 Installation and routeing of hoses and pipes Execute the on site pipe installation in accord ance with the applicable local regulations and standards Lay the hose installa...

Страница 16: ...ble sheath ing as used for tele communications and IT processing systems e g type LiYCY or Lightweight PVC control cable with shielded cable sheathing 7 Installation 7 1 Combining devices safely Take care when connecting units together or to parts of other systems as there is always an ele ment of risk e g due to leakage currents Only connect units when there can be no question of danger to operat...

Страница 17: ...Connect the exhaust air hose and suction hose to the floor connection Place the unit in the correct position and align Observe planning template 9000 619 09 100 200 Assembly A949100052L02 2104V003 15 EN ...

Страница 18: ...ing a compressor unit the compressor unit must have a star connection Mount the pressure tank Position the compressor unit in the unit Mount the compressor unit on the retaining plate using four nuts Also mount the second compressor unit optional on the retaining plate Fix the grounding cable Push on and secure the noise insulation on the suction manifold of the compressor unit Position the second...

Страница 19: ...tion manifold of the compressor unit 7 5 Install the drying unit Install the drying unit 1 2 Insert nozzle see installation instructions 9000 610 49 01 Insert the filter and close the drying unit with the cover 1 2 Assembly A949100052L02 2104V003 17 EN ...

Страница 20: ... Connect the drying unit to the compressed air hose coming out of the cooler Connect the drying unit to the pressure tank Assembly 18 A949100052L02 2104V003 EN ...

Страница 21: ...n containers at the inlet of the amalgam separator and the wastewater hose on the amalgam separator outlet Position the amalgam separator correctly in the Power Tower View Plug the mains cable into the mains socket on the BUS adapter 7 7 Connecting the unit Make sure that none of the electrical cables leading to the unit are under any mechanical tension Before start up check the mains voltage agai...

Страница 22: ...n nections and side panels 8 Commissioning Perform an electrical safety check prior to commissioning Switch on the main power switch Compressor will start and switches off at approx 0 75 MPa Open the condensate drain valve and drain the condensate Switch on the suction machine by removing the suction hose from the hose manifold or by activating the rinsing of the spittoon spittoon valve wet suctio...

Страница 23: ...he IEC 80001 1 standard for risk assessment The device is not suitable for direct connection to the public Internet Network configuration Various options are available for network configu ration ü Automatic configuration via DHCP recommen ded ü Automatic configuration via Auto IP for direct connection of unit and computer ü Manual configuration Configure the network settings of the unit using the ...

Страница 24: ...the buttons to switch to other menus Tap to switch to Settings Tap to scroll Tap to switch to the start screen Tap to switch to the previous menu level Tap to switch to the detail view for the alarm texts 9 3 Calling up messages on the touch screen Messages are divided into the following catego ries Fault Unit will no longer function When the error has been remedied it may be neces sary to acknowl...

Страница 25: ...number Firmware version 10 3 Configuring the units Use the Parameters menu to configure settings including Compressor pressure range Suction unit lag time Use the System settings menu to configure set tings including IP address Language 10 4 Amalgam separator Tap The fill level of the amalgam collecting con tainer and the pressure in the pressure tank are displayed Tap The humidity and the tempera...

Страница 26: ...ters in accordance with the maintenance schedule Maintenance interval Maintenance work At regular intervals Empty the collector tray under the drying unit the interval may vary depending on the ambient conditions and method of working empty it daily if the humidity is high Annually Replace the air intake filter in the compressor unit do this every six months if there is a high concentration of dus...

Страница 27: ...filter Replace the filter housing and close Wear parts and replacement parts The following working parts must be replaced at regular intervals refer also to Maintenance these articles do not bear the CE mark Air intake filter 0832 982 00 Fine filter 1610 121 00 Virus bacteria filter 1650100172 Sintered filter 1650 101 00 To configure the required filters or filter sets you can also use our filter ...

Страница 28: ...vice Prior to working on the unit or in case of danger disconnect it from the mains Error Possible cause Remedy Direction of rotating field incorrect The phases of the supply volt age cable have been mixed up The suction unit motor may be rotating in the wrong direction Switch the phases of the sup ply voltage cable Troubleshooting 26 A949100052L02 2104V003 EN ...

Страница 29: ...Appendix 13 Connection media plan PC board mit with CA 4 Appendix A949100052L02 2104V003 27 EN ...

Страница 30: ...14 Electrical connection plan 14 1 Version 400 V 3N L1 L2 PE L3 N U1 V1 W1 PE U1 V1 W1 PE PE U V W X13 X12 X11 X8 X4 X7 PE X23 X31 X21 L N PE Appendix 28 A949100052L02 2104V003 EN ...

Страница 31: ...separator motor Suction unit Inspect suction unit 1 Visible from access level Operator or higher 2 Visible from access level Administrator or higher 3 Visible from access level Service Technician or higher The access level Service Technician offers additional functions that must only be adjusted by Dürr Dental or by individuals companies authorised to do so by Dürr Dental Corresponding documents f...

Страница 32: ...the completeness of the delivery o Instruction in the proper handling and operation of the medical device based on the operating instructions Notes Name of person receiving instruction Signature Name and address of the qualified adviser for the medical device Date of handover Signature of the qualified adviser for the medi cal device Appendix 30 A949100052L02 2104V003 EN ...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...Hersteller Manufacturer DÜRR DENTAL SE Höpfigheimer Str 17 74321 Bietigheim Bissingen Germany Fon 49 7142 705 0 www duerrdental com info duerrdental com ...