background image

SAFETY ALERT SYMBOL

DANGER: This generator produces poisonous carbon monoxide gas when running. This 

gas is both odorless and colorless. Even if you do not see or smell gas, carbon monoxide 
may still be present. Breathing this poison can lead to headaches, dizziness, drowsiness, 
and eventually death. 

 

Use outdoors ONLY in non-confined areas. 

 

Keep several feet of clearance on all sides to allow proper ventilation of the generator.

WARNING: The exhaust from this product contains chemicals known to the State of 

California to cause cancer, birth defects, or other reproductive harm.

WARNING: This generator produces heat when running. Temperatures near exhaust can 

exceed 150°F (65°C). 

 

Do not touch hot surfaces. Pay attention to warning labels on the generator denoting 
hot parts of the machine. 

 

Allow generator to cool several minutes after use before touching engine or areas 
which heat during use.

The safety alert symbol is used with one of the safety words (

DANGER

CAUTION, or WARNING) to alert you of hazards. Please pay attention to 

these hazard notices both in this manual and on the generator.

GENERAL SAFETY PROCEDURES

7

Please familiarize yourself with the following safety symbols and words:

 

DANGER: Indicates a hazard that will result in serious injury or death if instructions are not 

followed.

 

WARNING: Indicates a strong possibility of causing serious injury or death if instructions are not 

followed.

 

CAUTION: Indicates a possibility of personal injury or equipment damage if instructions are not 

followed.

Содержание 991772K1

Страница 1: ... to ensure the accuracy of the information in this manual We reserve the right to change this product at any time without prior notice 5800 Ontario Mills Pkwy Ontario CA 91764 USA www duromaxpower com Call our Customer Care Team Toll Free 8 5pm PST Mon Fri 844 DUROMAX User Manual Gasoline Propane Tank Not Included REV XP10000EH 12132017 ...

Страница 2: ......

Страница 3: ...4 Check the Gas Level 25 Starting the Generator Using Gasoline 26 Starting the Generator Using Propane 28 Starting the Generator 2 Shipping Braces 18 Wheel Kit Installation 19 Adding Oil 20 Adding Gasoline 21 Grounding the Generator 22 High Altitude Operation 22 Generator Setup 4 AC Usage 32 Connecting a Load to the Generator 34 Voltage Selector Switch 35 DC Usage 36 Using the Generator 3 ...

Страница 4: ... Filter 44 Spark Plug Maintenance 46 Emptying the Gas Tank 48 Cleaning the Fuel Filter Cup 50 Storage and Transportation 51 Specifications 52 62 Basic Troubleshooting 54 Changing Inspecting the Carbon Brushes 55 Changing Inspecting the AVR 57 Maintenance and Care Warranty Troubleshooting 4 8 64 Contact Information ...

Страница 5: ......

Страница 6: ...torm that knocks out power dewatering a flooded property or washing away a deck for the summer season Engines that are certified to comply with U S EPA emission regulations for SORE Small off Road Equipment are certified to operate on regular unleaded gasoline and may include the following emission control systems EM Engine Modifications and TWC Three Way Catalyst if so equipped 6 STOP Please do n...

Страница 7: ... can exceed 150 F 65 C Do not touch hot surfaces Pay attention to warning labels on the generator denoting hot parts of the machine Allow generator to cool several minutes after use before touching engine or areas which heat during use The safety alert symbol is used with one of the safety words DANGER CAUTION or WARNING to alert you of hazards Please pay attention to these hazard notices both in ...

Страница 8: ...disconnect the spark plug WARNING This generator produces a powerful voltage which can result in electrocution ALWAYS ground the generator before using it see the Grounding the Generator portion of the PREPARlNG THE GENERATOR FOR USE section Generator should only be plugged into electrical devices either directly or with an extension cord NEVER connect to a building electrical system without a qua...

Страница 9: ...In addition to the above safety notices please familiarize yourself with the safety and hazard markings on the generator GENERAL SAFETY PROCEDURES 9 ...

Страница 10: ... full when you see fuel in the bottom of the fuel filter cup DO NOT overfill the tank 3 Turn gas valve on The gas valve is located above the recoil start on the bottom of the fuel tank Rotate the valve clockwise to the vertical position to turn on the gas supply 5 Add oil The oil fill cap is located on the lower engine block to the right of the recoil start housing Remove the oil fill cap and fill...

Страница 11: ...nd increase air into the carburetor for normal running 8 Connect devices Connect your devices to the receptacles on the front panel Start with the largest loads first 10 Start generator The key switch is located on the left side of the front power panel Insert the key and turn to the start position to start the generator Allow the key to return to the run position once started 7 Turn breaker on Th...

Страница 12: ...he generator 3 Connect propane hose The propane regulator decompression valve is located on the frame of the generator below the OHV valve cover Ensure the propane hose is securely connected to the regulator compression valve 5 Add oil The oil fill cap is located on the lower engine block to the right of the recoil start housing Remove the oil fill cap and fill with 10w30 oil 2 Turn gas valve off ...

Страница 13: ... of the front power panel Flip the breaker up to allow power to flow to the receptacles Connect your devices to the receptacles on the front panel Start with the largest loads first 10 Release propane pressure The propane regulator decompression valve is located on the frame of the generator below the OHV valve cover Press the button in the center down 3 5 times for one second to clear the air fro...

Страница 14: ...Gauge Indicates the amount of fuel in the gasoline tank 4 Fuel Cap Allows access to fill the gasoline tank 5 Circuit Breaker Resettable switch that protects the generator from electrical overload 6 120 240v 4 Prong Twist Lock Use to connect electrical devices that run 120 or 240 Volt 60Hz single phase AC current NEMA L14 30 7 Ground Terminal Connect a ground wire here to properly ground the genera...

Страница 15: ...Provides ignition to the engine 18 Muffler Reduces engine emissions and reduces noise 19 Propane Tank Connector and Hose Connects the LPG tank to the LPG Regulator 20 Propane Regulator and Pressure Release Valve Provides a regulated LPG Fuel supply to the engine Intended for use with a LPG Source of 3 PSI or more 21 120v 3 Prong Twist Lock Use to connect electrical devices that run 120 Volt 60 Hz ...

Страница 16: ... Wrench Plug Ends Phillips and slot blade screwdriver used for generator maintenance Used to add oil to the generator without messy spills Assorted wrenches used in generator maintenance and assembly Commonly 8mm 10mm 13mm and 15mm Used in conjunction with the charging posts to charge 12v automotive style batteries or small DC appliances Used in spark plug maintenance inspection and installation P...

Страница 17: ...GENERATOR SETUP Proper setup of your generator will get you going as soon as possible while making sure you and your equipment are safe and cared for ...

Страница 18: ...el or oil in the generator 1 Step 1 Remove Shipping Braces Remove braces a Completely remove each of the 4 bolts holding the orange metal brace in place b Remove the brace c Cut the nylon tie strap holding the wood brace in place d Grab the end of the second brace and pull it out e This piece is no longer needed and can be discarded 2 18 Note Shipping braces can be thrown away They will not be nee...

Страница 19: ...ptional Install Handles Attach the handles to the brackets on the frame using the provided bolts and nuts Do not over tighten the handles it will prevent free movement 3 Install wheels a Insert wheel bolt through frame and secure with provided nut b Slide one wheel over each axle end and secure with the provided retaining pins 2 ...

Страница 20: ... the engine s service life a Make sure the generator is on a level surface b Unscrew the oil filler dipstick cap from the engine c Using a funnel add the appropriate amount of oil into the crankcase You will know the crankcase is full when the oil level has reached the lower lip of the opening you have just poured the oil into d Replace oil filler cap 1 Step 3 Adding Oil Engine oil recommended SAE...

Страница 21: ...e top of the gas tank indicates how much gasoline is in the generator gas tank d Replace fuel cap and wipe up any spilled gasoline with a dry cloth NOTE Gas can expand Do not fill the gas tank to the very top Leave a minimum of 1 5 in of open space IMPORTANT Never use an oil gasoline mixture Never use old gas Avoid getting dirt or water in the fuel tank Gas can age in the tank and make it hard to ...

Страница 22: ...altitude that differs from that at which this engine was certified for extended periods of time may increase emissions High altitude performance can be improved by specific modifications to the carburetor If you always operate your generator at altitudes above 5 000 feet 1 500 meters have a dealer perform this carburetor modification This engine when operated at high altitude with the carburetor m...

Страница 23: ...e are still steps you should take to prepare it for operation each time you use it IMPORTANT At this point you should be familiar with the procedures described in the first portion of this section entitled GENERATOR SETUP If you have not yet read this section go back and read it now ...

Страница 24: ...ck cap c With a dry cloth wipe the oil off of the stick on the inside of the cap d Insert the dipstick as if you were replacing the cap and then remove again There should now be oil on the stick If there is no oil on the stick or oil only at the very end of the stick you should add oil until the engine crankcase is filled see Adding Oil portion of the Maintenance section e Be sure to replace the c...

Страница 25: ...ister with less than 1 3 fuel tank full 1 Step 2 Check the gas level WARNING Gasoline and gasoline fumes are highly flammable Do not fill tank near an open flame Always allow engine to cool for several minutes before refueling DO NOT overfill fuel tank Fuel expands when shaken or heated ALWAY leave 11 2 space or more at the top of the tank ALWAYS use fresh fuel or stabilized fuel Old gasoline olde...

Страница 26: ...bove the recoil start on the bottom of the fuel tank Rotate the valve clockwise to the vertical position to turn on the gas supply The choke lever is located above the air filter to the right of the recoil start Slide the lever to the left to cut the air supply and allow more gas into the engine to start The key switch is located on the left side of the front power panel Insert the key and turn to...

Страница 27: ...ng to start WARNING Operating the starter motor for more than 5 seconds can damage the motor If the engine fails to start release the switch and wait 10 seconds before operating the starter again 27 Turn engine switch to ON When the engine starts allow the engine switch to return to the ON position 5 Open choke Push the choke to the OPEN position as the engine warms up 6 ...

Страница 28: ...e the recoil start on the bottom of the fuel tank Rotate the valve counter clockwise to the horizontal position to stop the flow of gasoline to the carburetor The propane regulator decompression valve is located on the frame of the generator below the OHV valve cover Ensure the propane hose is securely connected to the regulator compression valve There propane hose is located on the left side of t...

Страница 29: ...nerator below the OHV valve cover Press the button in the center down 3 5 times for one second to clear the air from the lines and fill the carburetor 5 Adjust choke The choke lever is located above the air filter to the right of the recoil start Slide the lever to the right to open the choke and increase air into the carburetor for normal running 6 7 Start The key switch is located on the left si...

Страница 30: ...vices to generator ONLY after the engine runs smoothly There may be remnant gasoline in the carburetor this can cause unsteady engine performance for several minutes 3 If the propane gas leaks shut off the LPG supply first and then quickly unplug or turn off any electrical devices powered by the unit 4 When stopping the engine unplug or turn off any electrical devices turn off the Main Circuit Bre...

Страница 31: ...re still steps you should take to prepare it for operation each time you use it IMPORTANT At this point you should be familiar with the procedures described in the first portion of this section entitled GENERATOR SETUP If you have not yet read this section go back and read it now ...

Страница 32: ...ted wattage of the generator itself To calculate the total wattage requirement of the electrical devices you wish to connect find the rated or running wattage of each device This number should be listed somewhere on the device or in its instruction manual If you cannot find this wattage you may calculate it by multiplying the Voltage requirement by the Amperage drawn Watts Volts x Amps If these sp...

Страница 33: ...ectric drill 600 900 Television 500 0 Deep freezer 500 800 Garage door opener 480 600 Stereo 400 0 Box fan 300 600 Clock radio 300 0 Security system 180 0 DVD Player 100 0 Common light bulb 75 0 CAUTION The generator can only run at its surge wattage capacity for a very short time Connect only electrical devices requiring a rated running wattage equal to or less than the rated wattage of the gener...

Страница 34: ...nnected the 240v receptacle Plug in devices Turn breaker on Turn on connected devices Plug in devices to the appropriate receptacle When using the generator in 120 240v mode balance the load as closely as possible Placing more load on one side of the circuit will reduce the breaker trip period Flip the circuit breaker up to the on position to allow power to the receptacles Start or turn on applian...

Страница 35: ...e 120 240V position If only 120V appliances are being connected to the generator select the 120V ONLY position to double the 120v amperage and automatically balance the load Long or thin cords can drain the power provided to an electrical device by the generator When using such cords allow for a slightly higher rated wattage requirement for the electrical device See table below for recommended cor...

Страница 36: ...sitive receptacle Start Generator Connect one charging wire to the positive terminal on the battery and the other charging wire to the negative terminal on the battery Connect the free end of the positive wire to the positive receptacle outlet on the generator The key switch is located on the left side of the front power panel Insert the key and turn to the start position to start the generator Al...

Страница 37: ...n charging a battery DANGER If battery acid gets on your skin flush with water If battery acid gets in your eyes flush with water and call a physician immediately DANGER If battery acid is swallowed drink large quantities of milk and call a Physician immediately 37 Connect negative receptacle Carefully connect the free end of the negative wire to the negative receptacle on the generator 4 Disconne...

Страница 38: ...38 ...

Страница 39: ...nce and storage of your generator is essential to ensure trouble free use of your generator when you need it By following the maintenance and care requirements you can keep your generator running smooth and efficient for years to come 39 ...

Страница 40: ... instruction manual Make sure the engine is off before you begin any maintenance or repairs Let the engine and exhaust system cool before touching To reduce the possibility of fire or explosion be careful when working around gasoline Use only a nonflammable solvent not gasoline to clean parts Keep cigarettes sparks and flames away from all fuel related parts SERVICE REGULAR SERVICE PERIOD BEFORE E...

Страница 41: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 41 ...

Страница 42: ...Unscrew the oil filler dipstick cap c With a dry cloth wipe the oil off of the stick on the inside of the cap d Insert the dipstick as if you were replacing the cap and then remove again There should now be oil on the stick If there is no oil on the stick or oil only at the very end of the stick you should add oil until the engine crankcase is filled see Adding Oil portion of the Maintenance secti...

Страница 43: ...nated with water or dirt Remove drain plug Drain oil Replace drain plug Using a 10 mm hex wrench unscrew the oil drain plug which is located on the crankcase underneath the oil filler dipstick cap Allow all the oil to drain from the generator Drain oil into an approved oil disposal container Contact your local auto parts store for information on oil disposal Replace the oil drain plug and tighten ...

Страница 44: ...less air to enter the engine or dirty air to enter the engine causing overheating and engine wear MAINTENANCE AND CARE CONTINUED Cleaning the air filter Open filter cover Remove filter element Wipe out filter casing Unhinge the clasps at the top and bottom of the air cleaner cover Remove the sponge like elements from the casing Wipe the dirt from inside the empty air cleaner casing 1 2 3 44 ...

Страница 45: ... and replace the cover 7 45 Wash filter element Wash the sponge like elements in household dish detergent and warm water 4 Dry filter element Allow the elements to dry completely 5 6 Add engine oil to elements Soak the dry elements in a small amount of engine oil Ring out any excess oil ...

Страница 46: ...plug threads Spark Plug Maintenance Remove spark plug cap Remove spark plug Inspect spark plug Pull on the spark plug cap to remove it Unscrew the spark plug from the generator using the spark plug wrench included with this product Visually inspect the spark plug If it is cracked or chipped discard and replace with a new spark plug We recommend using a F6RTC spark plug such as NGK BPR5ES 1 2 3 MAI...

Страница 47: ...nd re gap Replace spark plug Replace spark plug cap If you are re using the spark plug use a wire brush to clean any dirt from around the spark plug base and then re gap the spark plug Screw the spark plug back into its place on the generator using the spark plug wrench Replace the spark plug cap 5 6 7 47 ...

Страница 48: ... Turn the fuel valve to the OFF position Remove the fuel filter cup see Removing the Fuel Filter Cup earlier in this section Empty the fuel filter cup of any fuel 1 2 3 CAUTION Do not store fuel from one season to another Gasoline sold at the pump today contains additives such as ethanol that even when stored properly may damage the fuel system components MAINTENANCE AND CARE CONTINUED 48 ...

Страница 49: ...lve to the ON position Drain all the gas from the generator 4 Shut fuel valve off Replace fuel filter cup Store emptied gas Turn the fuel valve to the OFF position Reinstall the fuel filter cup Store the emptied gasoline in a suitable place and add fuel stabilizer to keep fuel fresh and usable 5 6 7 49 ...

Страница 50: ...ion 1 Cleaning the fuel filter cup Remove fuel filter cup Clean filter cup Replace fuel filter cup Unscrew the fuel filter cup from the fuel valve using a wrench Turn the valve towards you to unscrew Clean the cup of all sediment using a rag or brush Reinstall the fuel filter cup 2 3 4 50 ...

Страница 51: ... unit to run 3 5 minutes 3 Turn off the fuel valve 4 Allow the unit to stall out 5 Turn off the key 6 Add fuel stabilizer to the gas remaining in the tank 7 Store If you do not plan to start the unit for longer than 30 days 1 Turn off the main breaker 2 Allow the unit to run 3 5 minutes 3 Turn off the fuel valve 4 Allow the unit to stall out 5 Turn off the key 6 Drain the fuel tank See Emptying th...

Страница 52: ...atedFrequency 60 Hz AC Phase Single DC Voltage 12V DC Amperage 8 3A Dimensions LENGTH 28in WIDTH 22in HEIGHT 23in Engine Type 4 Stroke OHV Forced Air Ignition System Non Contact Transistor Displacement 420cc Starting Type Electric Fuel Tank Capacity 7 9 US Gal 30L Oil Capacity 37 fl oz 1 1L Run Time 50 Gasoline 10 hr Run Time 50 Propane 5 hr 5 Gallon Noise Level 74db 52 ...

Страница 53: ...TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator 53 ...

Страница 54: ...l Move generator to a level surface Oil is low Add change oil Engine runs but there is no electrical output Circuit breaker is Off Turn on circuit breaker Wiring connection is bad Replace extension cord s Device connected to generator is malfunctioning Disconnect malfunctioning device Generator runs but does not support all electrical devices connected Generator is overloaded Disconnect 1 or more ...

Страница 55: ...bon brushes are wearable parts and should be inspected every 250 running hours Remove generator cover Remove bolt from brush Disconnect AVR wires Remove the 2 bolts of the generator cover then pull the cover off the generator Remove the bolt holding the carbon brush Remove the two wires from the AVR on the carbon brush 1 2 3 55 ...

Страница 56: ...ush Install new carbon brush with bolt 4 Connect AVR wires Insert and connect the 2 wires from the AVR be sure to connect and correctly 5 6 Replace generator cover Replace the back cover of the generator and secure with the 2 bolts TROUBLESHOOTING CONTINUED 56 ...

Страница 57: ...or If the generator is overheated or overloaded the AVR may be damaged and require replacement Remove generator cover Remove AVR bolts Disconnect AVR wire clip Remove the 2 bolts of the generator cover then pull the cover off the generator Remove the 2 bolts holding the AVR Disconnect the wire clip 1 2 3 57 ...

Страница 58: ...to connect and correctly 7 Disconnect wires from brush Remove the 2 wires from the AVR on the carbon brush 4 Install new AVR Install the new AVR with the 2 bolts 5 6 Reconnect wires to brush Reconnect the wire clip Changing Inspecting the AVR Continued TROUBLESHOOTING CONTINUED 58 ...

Страница 59: ...Replace generator cover Replace the back cover of the generator and secure with the 2 bolts 8 59 ...

Страница 60: ...WIRING DIAGRAM 60 ...

Страница 61: ...61 ...

Страница 62: ...ransferable and only valid to the original purchaser Warranty Exclusions The DuroMax DuroStar Power Equipment warranty does not cover repairs or returns when the fault is Normal Wear and Tear Installation Use or Maintenance Services Cosmetic defects Accessories Failures due to acts of God or Natural Disasters or problems related to from aftermarket or non OEM parts Warranty Limitations DuroMax Dur...

Страница 63: ...63 ...

Страница 64: ...ors are your lifeline in the event of an emergency Should you have any problems please contact our customer service department DUROMAX POWER EQUIPMENT 5800 Ontario Mills Parkway Ontario CA 91764 Customer Service 844 DUROMAX Customer Service Hours 8 5pm PST Website www duromaxpower com Email customer_service duromaxpower com ...

Страница 65: ......

Страница 66: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX ...

Отзывы: