Installation Instructions

All government codes and regulations governing the installation of these devices must be observed.

CAUTION:

If the ground from the electrical panel or breaker box to the water meter or 

underground copper pipe is tied to the copper water lines and these lines are cut during installation of the Noryl bypass
valve and/or poly pipe, an approved grounding strap must be used between the two lines that have been cut in order to
maintain continuity. The length of the grounding strap will depend upon the number of units being installed and/or the
amount of copper pipe being replaced with poly. See Figure 1.

In all cases where metal pipe was originally used and is
later interrupted by poly pipe or the Noryl bypass valve as
in Figure 1 or by physical separation as in Figure 2,

An approved ground clamp with no less than #6 copper
conductor must be used for continuity, to maintain proper
metallic pipe bonding. Check your local electrical code for
the correct clamp and cable size.

Check your local electrical code for the correct clamp and
cable size.

1.  Determine the best location for your water softener,

bearing in mind the location of your water supply lines,
drain line and 120 volt AC electrical outlet. Subjecting the
softener to freezing or temperatures above 110°F
(43°C)will void the warranty.

Media Installation (When Necessary)

Remove the valve from the mineral tank.

Temporarily plug the open end of the riser tube to ensure
that no resin or gravel falls down into the distribution.

Fill mineral tank one quarter full of water to protect
distribution during gravel installation.

Slowly and carefully add the gravel support bed and the
softener or filtration media leveling each layer as it is
placed into the tank.

Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the fiberglass tank,
tightening securely into tank. Note: Ensure that the internal O-ring in the valve fits securely over the riser tube.
Silicone grease (#13691) or other food grade lubricant may be applied to the O-ring to ease installation of the riser
tube. DO NOT use petroleum based lubricants as they will cause swelling of O-ring seals.

The softener or filter is now charged with softening resin.

It is recommended that the softener or filter tank now be completely filled with water (SLOWLY) to soak the resin or
filtration media before startup. This will allow the media to absorb water as well as help displace any trapped air.
This will reduce the chance of backwashing resin or filter media out of the tank during the initial backwash on
startup.

2.  Outside faucets used to water lawns and gardens should not supply softened water. A new water line is often

required to be connected to supply hard water to the inlet of the water softener and to the outside faucets. Cut the
water line between where it enters the house and before any lines that branch off to feed the hot water heater or
other fixtures in the house and as near the desired location of the water softener as possible. Install a tee fitting on
the feed end of the cut pipe, and an elbow fitting on the other end. Install piping from the tee to the inlet of the water
softener and from the elbow to the outlet of the softener. To sever the water lines which branch off to feed any
outside faucets, cut the branch lines approximately two inches from the fitting on the main water line. Install an
elbow on the end of the pipe nearest the outside faucet and a cap on the end connected to the existing water line.
Install piping from the tee installed on the inlet line to the water softener to the elbow installed on the pipe to the
outside faucet. Following this procedure will result in all lines in the house, with the exception of the outside faucets,
but including the water heater and therefore the hot water lines, being supplied with soft water.

3.  Familiarize yourself with the location of the inlet, outlet and drain on the control valve. Be very careful not to get the

controls wet.

Figure 2

Figure 1

Electrical Panel

Ground Strap

Poly Pipe

Ground
From
Panel

Poly Pipe

Softener
c/w Plastic Bypass

Copper Pipe

Water Meter

Outside Water Line For Outside & 3rd Tap Comes From Meter

Filtered Water Line in Home

Unfiltered Water Bypass
Loop Cut & Capped

Ground Strap Required 
Because of Break in Continuity

Содержание 9100SXT

Страница 1: ...ener OPERATION MANUAL 54746 2 09 PLEASE NOTE On page nine of this manual you will find important maintenance procedures for the continued proper operation of your unit These MUST be performed regularly for your guarantee to remain valid ...

Страница 2: ...ompleted the valve will return to Service and resume normal operation Example Less than 6 minutes remaining in Regen Step Rapid Rinse Pushing the Extra Cycle Button during a regeneration cycle will immediately advance the valve to the next cycle step position and resume normal step timing 1 5 Performance PM Indicator Flow Indicator Flashing with water flow PM Indicator Flow Indicator Flashing with...

Страница 3: ... the system on a timed interval The control will initiate a regeneration cycle at the programmed regeneration time when the number of days since the last regeneration equals the regeneration day override value Day of the Week Control This control regenerates the system on a weekly schedule The schedule is defined in Master Programming by setting each day to either off or on The control will initia...

Страница 4: ...O ring to ease installation of the riser tube DO NOT use petroleum based lubricants as they will cause swelling of O ring seals The softener or filter is now charged with softening resin It is recommended that the softener or filter tank now be completely filled with water SLOWLY to soak the resin or filtration media before startup This will allow the media to absorb water as well as help displace...

Страница 5: ...to the tank to speed up the filling but the valve should be in the Brine Refill position for a minimum of two minutes to purge the air out of the injector set 10 Press the extra cycle button to advance the valve from the Brine Fill position through service to the 2 position Brine Rinse position Verify that water is being drawn from the tank If not repeat step 9 11 Press the extra cycle button to a...

Страница 6: ...nd hold either the Up or Down buttons until the programming icon replaces the service icon and the parameter display reads TD 2 Adjust the displayed time with the Up and Down buttons 3 When the desired time is set press the Extra Cycle button to resume normal operation The unit will also return to normal operation after 5 seconds if no buttons are pressed Queueing a Regeneration 1 Press the Extra ...

Страница 7: ...ps 1 Press the Up and Down buttons for five seconds while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen THIS IS AN OPTION ONLY PLEASE DO NOT ADJUST BEFORE CONSULTING AN AUTHORIZED DEALER 3 Press the Extra Cycle button Use this display to adjust the Feed Water Ha...

Страница 8: ...st regeneration All individual settings d1 d2 d3 d4 d5 d6 d7 are set to 0 Control board memory failure Unplug the unit from the power source When power is restored to the unit the Err _ display code clears If the condition causing the error has not been resolved the Err _ code reappears in the four digit display Do not attempt to troubleshoot this problem any further Regeneration must occur for th...

Страница 9: ...d be performed when little or no water will be used in the household Safety Float The brine tank is equipped with a safety float which prevents your brine tank from over filling as a result of a malfunction such as a power failure Water Pressure Your softener is designed to operated under normal water pressures from 20 psi 1 4 atm to 100 psi 8 2 atm New Sounds You may notice new sounds as your wat...

Страница 10: ...of Your Softener To retain the attractive appearance of your new water softener clean occasionally with a mild soap solution Do not use abrasive cleaners ammonia or solvents Never subject your softener to freezing or to temperatures above 110 F 43 C Cleaning the Injector Assembly Figure 7 Sediment salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this...

Страница 11: ...ir eliminator control Check for dry well condition Drain line flow control is too large Ensure drain line flow control is sized 6 IRON IN CONDITIONED WATER Fouled resin bed Check backwash brine draw and brine tank fill Increase frequency of regeneration Increase backwash time Iron content exceeds recommended parameters Add iron removal filter system 7 EXCESSIVE WATER IN BRINE TANK Plugged drain li...

Страница 12: ...l be from the date thereof Lifetime Guarantee on Mineral Tanks and Brine Tanks WaterGroup Companies Inc will provide a replacement mineral tank or brine tank to any original equipment purchaser in possesion of a tank that fails within his her lifetime provided that the water conditioner is at all times operated in accordance with specifications and not subject to freezing General Provisions WaterG...

Отзывы: